The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Hamstring tendon fixation using interference screws: a biomechanical study in calf tibial bone
Abstract
It has recently been shown that graft fixation close to the ACL insertion site is optimal in order to increase anterior knee stability. Hamstring tendon fixation using interference screws offers this possibility and a round threaded titanium interference screw has been previously developed. The use of a round threaded biodegradable interference screw may be equivalent. In addition, to increase initial fixation strength, graft harvest with a distally attached bone plug may be advantageous, but biomechanical data do not exist. This study compares the initial pullout force, stiffness of fixation, and failure modes of three strand semitendinosus grafts in 36 proximal calf tibiae using either biodegradable poly-(D,L-lactide) (Sysorb; Sulzer Orthopaedics Ltd, Münsingen, Switzerland) or round threaded titanium (RCI; Smith & Nephew DonJoy, Carlsbad, CA) interference screws, harvested either without (biodegradable: group I, titanium III) or with (biodegradable: group II, titanium: group IV) attached tibial bone plugs. Maximum pullout force in group I (507 +/- 93 N) was significantly higher than in group III (419 +/- 77 N). Pullout force of bone plug fixation was significantly higher than that of direct tendon fixation (717 +/- 90 N in group II and 602 +/- 117 N in group IV). Pullout force of biodegradable fixation was significantly higher in both settings. These results indicate that initial pullout force of hamstring-tendon graft interference screw fixation can be increased by using a biodegradable interference screw. In addition, initial pullout force of hamstring-tendon graft fixation with an interference screw can be greatly increased by harvesting the graft with its distally attached tibial bone plug.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Markolf, K. L., Gorek, J. F., Kabo, J. M., & Shapiro, M. S. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072040-00014 · Cited by 610
Preliminary results of an absorbable interference screw
Barber, F. A., Elrod, B. F., McGuire, D. A., & Paulos, L. E. (1995) · Arthroscopy · doi:10.1016/0749-8063(95)90129-9 · Cited by 178
Cited by
Tendon healing in a bone tunnel. Part II
Weiler, A., Hoffmann, R. F. G., Bail, H. J., Rehm, O., & Südkamp, N. P. (2002) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/jars.2002.30657 · Cited by 481
Self-citationGraft Fixation in Cruciate Ligament Reconstruction
Brand, J., Weiler, A., Caborn, D. N. M., Brown, C. H., & Johnson, D. L. (2000) · The American Journal of Sports Medicine · doi:10.1177/03635465000280052501 · Cited by 436
Self-citationKousa, P., Järvinen, T. L. N., Vihavainen, M., Kannus, P., & Järvinen, M. (2003) · The American Journal of Sports Medicine · doi:10.1177/03635465030310020401 · Cited by 426
Shaieb, M. D., Kan, D. M., Chang, S. K., Marumoto, J. M., & Richardson, A. B. (2002) · The American Journal of Sports Medicine · doi:10.1177/03635465020300021201 · Cited by 331
Weiler, A., Peters, G., Mäurer, J., Unterhauser, F. N., & Südkamp, N. P. (2001) · The American Journal of Sports Medicine · doi:10.1177/03635465010290061401 · Cited by 287
Self-citation
Metadata
- Authors
- Weiler, A., Hoffmann, R., Stähelin, A., Bail, H., Siepe, C., & Südkamp, N.
- Venue
- Arthroscopy: The Journal of Arthroscopic & Related Surgery
- Publisher
- Elsevier BV
- Published
- 1998-01
- Volume
- 14
- Issue
- 1
- Pages
- 29-37
- ISSN
- 0749-8063 (ISSN-L)
- OpenAlex
- W2005945793
- Cited by
- 201
- References
- 2
- FWCI
- 13.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hamstring tendon fixation using interference screws: a biomechanical study in calf tibial bone. https://app.cochat.ai/papers/10.1016/s0749-8063(98)70117-3
- The paper
- Weiler, A., Hoffmann, R., Stähelin, A., Bail, H., Siepe, C., & Südkamp, N. (1998). Hamstring tendon fixation using interference screws: a biomechanical study in calf tibial bone. Arthroscopy: The Journal of Arthroscopic & Related Surgery. https://doi.org/10.1016/s0749-8063(98)70117-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.