Comparison of two dental devices for treatment of obstructive sleep apnea syndrome (OSAS)
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Previous case reports have indicated dental devices can be an effective nonsurgical treatment for snoring and obstructive sleep apnea. This pilot study evaluated the effectiveness of two intraoral devices in reducing the Respiratory Disturbance Index (RDI) and Epworth Sleepiness Scale (ESS) scores in a group of 24 adult volunteers with a history of loud snoring. Subjects were randomly assigned to two groups. Twelve subjects were fitted with a dental device designed to increase vertical dimension and protrude the mandible (device A). The other 12 subjects received a different device designed to minimally increase vertical opening without protruding the mandible (device B). Unattended home sleep monitoring (Edentrace II Digital Recorder, Edentech Corp.) was used to compute RDI at two time periods: (T0) before using any dental device and (T1) while using a dental device 2 weeks after the initial delivery date. The mean RDI and ESS scores at T0 for subjects in the device A group were 35.6 +/- 28.4 and 12.0 +/- 3.9, respectively. Means for the same measures at T1 were 21.1 +/- 21.4 and 8.2 +/- 4.0. For subjects in the device B group, means for RDI and ESS scores at T0 were 36.5 +/- 43.7 and 13.0 +/- 4.5, the means at T1 were 46.8 +/- 47.0 and 12.5 +/- 5.7. The effectiveness of the two devices was estimated by comparing the difference in RDI scores from T0 to T1 for the 10 subjects who were using device A and completed the study and the 8 subjects who were using device B and comple…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Subjective daytime sleepiness decreased from MAD treatment compared with placebo according to many short-term studies 62, 64, 66, 68, 70, although control treatment may also give positive effects 64, 69.”
From Non-CPAP therapies in obstructive sleep apnoea (2011) · cites this paper as [62]
In the citing paper
“MAD treatment reduced sleep apnoeas compared with placebo in all studies 62–66, 68–70.”
From Non-CPAP therapies in obstructive sleep apnoea (2011) · cites this paper as [62]
In the citing paper
“The degree of mandibular advancement is crucial, since a non-advanced device is ineffective on sleep apnoeas 62, 65, 70 and may even increase the apnoea frequency 62.”
From Non-CPAP therapies in obstructive sleep apnoea (2011) · cites this paper as [62]
Citations
Cites
A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale
Johns, M. W. (1991) · Sleep · doi:10.1093/sleep/14.6.540 · Cited by 17,364
The Occurrence of Sleep-Disordered Breathing among Middle-Aged Adults
Young, T., Palta, M., Dempsey, J., Skatrud, J., Weber, S., & Badr, S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199304293281704 · Cited by 10,183
Cephalometric Analyses and Flow-Volume Loops in Obstructive Sleep Apnea Patients
Riley, R., Guilleminault, C., Herran, J., & Powell, N. (1983) · Sleep · doi:10.1093/sleep/6.4.303 · Cited by 488
Sleep Apnea -- A Major Public Health Problem
Phillipson, E. A. (1993) · New England Journal of Medicine · doi:10.1056/nejm199304293281712 · Cited by 410
GLOSSOPTOSIS DUE TO ATRESIA AND HYPOTROPHY OF THE MANDIBLE
ROBIN, P. (1934) · Archives of Pediatrics & Adolescent Medicine · doi:10.1001/archpedi.1934.01960160063005 · Cited by 407
Cephalometric analysis for diagnosis and treatment of obstructive sleep apnea
Deberry‐Borowiecki, B., Kukwa, A., & Blanks, R. H. I. (1988) · The Laryngoscope · doi:10.1288/00005537-198802000-00021 · Cited by 319
The Herbst appliance—Its biologic effects and clinical use
Pancherz, H. (1985) · American Journal of Orthodontics · doi:10.1016/0002-9416(85)90169-1 · Cited by 318
Obstructive Sleep Apnea and Cephalometric Roentgenograms
Partinen, M., Guilleminault, C., Quera-Salva, M.-A., & Jamieson, A. (1988) · Chest · doi:10.1378/chest.93.6.1199 · Cited by 283
The Effects of a Nonsurgical Treatment for Obstructive Sleep Apnea: The Tongue-Retaining Device
Cartwright, R. D. (1982) · JAMA · doi:10.1001/jama.1982.03330060045032 · Cited by 268
Treatment of Snoring and Obstructive Sleep Apnea with a Dental Orthosis
Schmidt-Nowara, W. W., Meade, T. E., & Hays, M. B. (1991) · Chest · doi:10.1378/chest.99.6.1378 · Cited by 208
Cited by
Oral Appliances for Snoring and Obstructive Sleep Apnea: A Review
Ferguson, K. A., Cartwright, R., Rogers, R., & Schmidt-Nowara, W. (2006) · Sleep · doi:10.1093/sleep/29.2.244 · Cited by 687
Qaseem, A., Dallas, P., Owens, D. K., Starkey, M., Holty, J.-E. C., Shekelle, P., & for the Clinical Guidelines Committee of the American College of Physicians* (2014) · Annals of Internal Medicine · doi:10.7326/m12-3187 · Cited by 516
Oral Appliance Treatment for Obstructive Sleep Apnea: An Update
Sutherland, K., Vanderveken, O. M., Tsuda, H., Marklund, M., Gagnadoux, F., Kushida, C. A., Cistulli, P. A., & on behalf of the ORANGE-Registry (Oral Appliance Network on Global Effectiveness) (2014) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.3460 · Cited by 515
“All studies found in favor of the active appliance in reduction in AHI 14,15,17,20 and arousal index, 15 and improving oxygen saturation.”
Oral appliances for obstructive sleep apnoea
Lim, J., Lasserson, T. J., Fleetham, J., & Wright, J. J. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004435.pub3 · Cited by 418
The Epworth Sleepiness Scale may not reflect objective measures of sleepiness or sleep apnea
Chervin, R. D., & Aldrich, M. S. (1999) · Neurology · doi:10.1212/wnl.52.1.125 · Cited by 395
Metadata
- Authors
- Hans, M. G., Nelson, S., Luks, V. G., Lorkovich d, P., & Baek, S.-J.
- Affiliations
- Case Western Reserve University (US)
- Venue
- American Journal of Orthodontics and Dentofacial Orthopedics
- Publisher
- Elsevier BV
- Published
- 1997-05
- Volume
- 111
- Issue
- 5
- Pages
- 562-570
- ISSN
- 0889-5406 (ISSN-L)
- OpenAlex
- W2004158204
- Cited by
- 123
- References
- 29
- Citations by year
- 2025: 1 · 2024: 2 · 2023: 6 · 2022: 3 · 2021: 2 · 2020: 4 · 2019: 3 · 2018: 2 · 2017: 3 · 2016: 8 · 2015: 4 · 2014: 20 · 2013: 6 · 2012: 5
- FWCI
- 1.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- American Journal of Orthodontics and Dentofacial Orthopedics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r03de010672-02)
- National Heart, Lung, and Blood Institute (P50HL042215, HL 42215, R01HL046380, HL 46380)
- National Institute of Dental and Craniofacial Research (DE10672)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Health Sciences › Dentistry › Oral Surgery › Temporomandibular Joint Disorders
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Keywords
- obstructive sleep apnea, dental devices, mandibular advancement, snoring, respiratory disturbance index, Epworth Sleepiness Scale, home sleep monitoring, vertical dimension of occlusion, treatment effectiveness comparison, daytime sleepiness, apnea-hypopnea index, apnea index, oxygen desaturation
- MeSH terms
- Adult, Aged, Equipment Design, Female, Follow-Up Studies, Humans, Male, Mandible, Middle Aged, Patient Compliance, Pharynx, Pilot Projects, Sleep Apnea Syndromes, Snoring, Vertical Dimension, Occlusal Splints, Polysomnography, Cross-Over Studies, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of two dental devices for treatment of obstructive sleep apnea syndrome (OSAS). https://app.cochat.ai/papers/10.1016/s0889-5406(97)70293-2
- The paper
- Hans, M. G., Nelson, S., Luks, V. G., Lorkovich d, P., & Baek, S.-J. (1997). Comparison of two dental devices for treatment of obstructive sleep apnea syndrome (OSAS). American Journal of Orthodontics and Dentofacial Orthopedics. https://doi.org/10.1016/s0889-5406(97)70293-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.