CoChat

Comparison of two dental devices for treatment of obstructive sleep apnea syndrome (OSAS)

Hans, Mark G., Nelson, Suchitra, Luks, Virginia G., Lorkovich d, Paul, Baek, Seung-Jin · 1997 · American Journal of Orthodontics and Dentofacial Orthopedics

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Abstract

Previous case reports have indicated dental devices can be an effective nonsurgical treatment for snoring and obstructive sleep apnea. This pilot study evaluated the effectiveness of two intraoral devices in reducing the Respiratory Disturbance Index (RDI) and Epworth Sleepiness Scale (ESS) scores in a group of 24 adult volunteers with a history of loud snoring. Subjects were randomly assigned to two groups. Twelve subjects were fitted with a dental device designed to increase vertical dimension and protrude the mandible (device A). The other 12 subjects received a different device designed to minimally increase vertical opening without protruding the mandible (device B). Unattended home sleep monitoring (Edentrace II Digital Recorder, Edentech Corp.) was used to compute RDI at two time periods: (T0) before using any dental device and (T1) while using a dental device 2 weeks after the initial delivery date. The mean RDI and ESS scores at T0 for subjects in the device A group were 35.6 +/- 28.4 and 12.0 +/- 3.9, respectively. Means for the same measures at T1 were 21.1 +/- 21.4 and 8.2 +/- 4.0. For subjects in the device B group, means for RDI and ESS scores at T0 were 36.5 +/- 43.7 and 13.0 +/- 4.5, the means at T1 were 46.8 +/- 47.0 and 12.5 +/- 5.7. The effectiveness of the two devices was estimated by comparing the difference in RDI scores from T0 to T1 for the 10 subjects who were using device A and completed the study and the 8 subjects who were using device B and comple…

Overview

Integrity signals

Registry

Crossref · 10.1016/s0889-5406(97)70293-2

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 29 references

Cited by

See all 123

Metadata

Authors
Hans, M. G., Nelson, S., Luks, V. G., Lorkovich d, P., & Baek, S.-J.
Affiliations
Case Western Reserve University (US)
Venue
American Journal of Orthodontics and Dentofacial Orthopedics
Publisher
Elsevier BV
Published
1997-05
Volume
111
Issue
5
Pages
562-570
ISSN
0889-5406 (ISSN-L)
OpenAlex
W2004158204
Cited by
123
References
29
Citations by year
2025: 1 · 2024: 2 · 2023: 6 · 2022: 3 · 2021: 2 · 2020: 4 · 2019: 3 · 2018: 2 · 2017: 3 · 2016: 8 · 2015: 4 · 2014: 20 · 2013: 6 · 2012: 5
FWCI
1.00
Type
journal article
Language
en
Open access
closed
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Locations
  • American Journal of Orthodontics and Dentofacial Orthopedics (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (5r03de010672-02)
  • National Heart, Lung, and Blood Institute (P50HL042215, HL 42215, R01HL046380, HL 46380)
  • National Institute of Dental and Craniofacial Research (DE10672)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Health Sciences › Dentistry › Oral Surgery › Temporomandibular Joint Disorders
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
Keywords
obstructive sleep apnea, dental devices, mandibular advancement, snoring, respiratory disturbance index, Epworth Sleepiness Scale, home sleep monitoring, vertical dimension of occlusion, treatment effectiveness comparison, daytime sleepiness, apnea-hypopnea index, apnea index, oxygen desaturation
MeSH terms
Adult, Aged, Equipment Design, Female, Follow-Up Studies, Humans, Male, Mandible, Middle Aged, Patient Compliance, Pharynx, Pilot Projects, Sleep Apnea Syndromes, Snoring, Vertical Dimension, Occlusal Splints, Polysomnography, Cross-Over Studies, Monitoring, Ambulatory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of two dental devices for treatment of obstructive sleep apnea syndrome (OSAS). https://app.cochat.ai/papers/10.1016/s0889-5406(97)70293-2
The paper
Hans, M. G., Nelson, S., Luks, V. G., Lorkovich d, P., & Baek, S.-J. (1997). Comparison of two dental devices for treatment of obstructive sleep apnea syndrome (OSAS). American Journal of Orthodontics and Dentofacial Orthopedics. https://doi.org/10.1016/s0889-5406(97)70293-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.