The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Measurements of temperature distribution in ground
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The working principle of ground-source cooling is based on the fact that the ground temperature below approximately 10 m remains fairly constant all year round at about mean annual ambient air temperature [210].”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [210]
Citations
Cites
Analysis of heat and mass transfer
Eckert, E. R. G., & Drake, R. M. (1971) · Medical Entomology and Zoology · Cited by 1,993
On the application of the energy balance equation to predict ground temperature profiles
Mihalakakou, G. K., Santamouris, M., Lewis, J. O., & Asimakopoulos, D. N. (1997) · Solar Energy · doi:10.1016/s0038-092x(97)00012-1 · Cited by 209
Remote prediction of ground temperature in Australian soils and mapping its distribution
Baggs, S. A. (1983) · Solar Energy · doi:10.1016/0038-092x(83)90189-5 · Cited by 86
A new computerized approach to estimating the thermal properties of unfrozen soils
Tarnawski, V. R., & Wagner, B. (1992) · Canadian Geotechnical Journal · doi:10.1139/t92-079 · Cited by 47
Australian Earth-Covered Building
Baggs, S. A., Baggs, J. C., & Baggs, D. (1991) · Cited by 17
Cited by
Seawater desalination using renewable energy sources
KALOGIROU, S. (2005) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2005.03.001 · Cited by 1,169
Ground heat exchangers—A review of systems, models and applications
Florides, G. A., & Kalogirou, S. A. (2007) · Renewable Energy · doi:10.1016/j.renene.2006.12.014 · Cited by 768
A comprehensive study of geothermal heating and cooling systems
Soltani, M., M. Kashkooli, F., Dehghani-Sanij, A. R., Kazemi, A. R., Bordbar, N., Farshchi, M. J., Elmi, M., Gharali, K., & B. Dusseault, M. (2019) · Sustainable Cities and Society · doi:10.1016/j.scs.2018.09.036 · Cited by 257
Numerical and experimental analysis of a horizontal ground-coupled heat pump system
Esen, H., İnallı, M., & Esen, M. (2006) · Building and Environment · doi:10.1016/j.buildenv.2005.11.027 · Cited by 244
Zeng, Y.-C., Su, Z., & Wu, N.-Y. (2013) · Energy · doi:10.1016/j.energy.2013.04.055 · Cited by 199
Metadata
- Authors
- Popiel, C. O., Wojtkowiak, J., & Biernacka, B.
- Affiliations
- Poznań University of Technology (PL)
- Bialystok University of Technology (PL)
- Corresponding author
- Popiel, C.O
- ORCID
- Wojtkowiak, J
- Venue
- Experimental Thermal and Fluid Science
- Publisher
- Elsevier BV
- Published
- 2001-11
- Volume
- 25
- Issue
- 5
- Pages
- 301-309
- ISSN
- 0894-1777 (ISSN-L)
- OpenAlex
- W2007907415
- Cited by
- 219
- References
- 5
- Citations by year
- 2026: 7 · 2025: 12 · 2024: 12 · 2023: 8 · 2022: 14 · 2021: 14 · 2020: 10 · 2019: 13 · 2018: 12 · 2017: 15 · 2016: 15 · 2015: 13 · 2014: 14 · 2013: 10 · 2012: 8
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Experimental Thermal and Fluid Science (publishedVersion)
- Topics
- Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Geothermal Energy Systems and Applications
- Physical Sciences › Engineering › Civil and Structural Engineering › Soil and Unsaturated Flow
- Physical Sciences › Environmental Science › Environmental Engineering › Urban Heat Island Mitigation
- Keywords
- ground temperature distribution, soil temperature, heat flux, seasonal temperature variation, ground heat exchangers, thermal energy storage, building heat loss, parking lots, Poznań
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurements of temperature distribution in ground. https://app.cochat.ai/papers/10.1016/s0894-1777(01)00078-4
- The paper
- Popiel, C. O., Wojtkowiak, J., & Biernacka, B. (2001). Measurements of temperature distribution in ground. Experimental Thermal and Fluid Science. https://doi.org/10.1016/s0894-1777(01)00078-4