Flow, heat transfer, and pressure drop in the near-wall region of louvered-fin arrays
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Fluid is periodically entrained in the recirculation zones and then ejected in the form of vortices which are carried downstream [8].”
From Comprehensive Study of Heat Exchangers with Louvered Fins (2017) · cites this paper as [8]
In the citing paper
“Two counter-rotating cells are present between the louvers.”
From Comprehensive Study of Heat Exchangers with Louvered Fins (2017) · cites this paper as [8]
In the citing paper
“This large recirculation zone circulates in a clockwise direction, resulting in a region of very high shear near the trailing edge of the louver where flow that passes downstream between fins interacts with the separation bubble.”
From Comprehensive Study of Heat Exchangers with Louvered Fins (2017) · cites this paper as [8]
In the citing paper
“The third recirculation zone has grown to become as large as the first zone, and the small second zone is no longer clearly evident.”
From Comprehensive Study of Heat Exchangers with Louvered Fins (2017) · cites this paper as [8]
In the citing paper
“This third recirculation zone is caused when the flow passes through the gap between the first recirculation zone and the next louver downstream.”
From Comprehensive Study of Heat Exchangers with Louvered Fins (2017) · cites this paper as [8]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
A generalized heat transfer correlation for Iouver fin geometry
Chang, Y.-J., & Wang, C.-C. (1997) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(96)00116-0 · Cited by 493
Heat transfer and pressure drop characteristics of flat tube and louvered plate fin surfaces
Achaichia, A., & Cowell, T. A. (1988) · Experimental Thermal and Fluid Science · doi:10.1016/0894-1777(88)90032-5 · Cited by 235
Prediction of Heat Transfer and Friction for the Louver Fin Geometry
Sahnoun, A., & Webb, R. L. (1992) · Journal of Heat Transfer · doi:10.1115/1.2911898 · Cited by 69
Research works printed but not linked: 22
- DeJong, 1997, An experimental study of flow and heat transfer in parallel-plate arrays: local, row-by-row and surface average behavior, International Journal of Heat and Mass Transfer, 40, 1365, 10.1016/S0017-9310(96)00186-X · DOI
- Davenport, 1983, Correlations for heat transfer and flow friction characteristics of louvred fin, AIChE Symposium Series 225, 79, 19
- Chang, 1996, Air side performance of brazed aluminum heat exchangers, Journal of Enhanced Heat Transfer, 3, 15, 10.1615/JEnhHeatTransf.v3.i1.20 · DOI · Paper page
- Achaichia, 1988, A finite difference analysis of fully developed periodic laminar flow in inclined louvre arrays, Proceedings of the 2nd U.K. National Heat Transfer Conference, Glasgow, 1, 883
- Hiramatsu, 1990, Research on fins for air conditioning heat exchangers, JSME International Journal, Series II, 33, 749
- Suga, 1990, Numerical analysis on two-dimensional flow and heat transfer of louvered fins using overlaid grids, JSME International Journal, Series II, 33, 122
- Suga, 1991, Numerical study on heat transfer and pressure drop on multilouvered fins, ASME/JSME Thermal Engineering Proceedings, ASME, New York, 4, 361
- E.R. Dillen, R.L. Webb, Rationally based heat transfer and friction correlations for the louver fin geometry, SAE Paper 950504, Detriot, 1994 · DOI · Paper page
- Webb, 1991, Flow structure in the louvered fin heat exchanger geometry, Experimental Thermal and Fluid Science, 4, 205, 10.1016/0894-1777(91)90065-Y · DOI · Paper page
- Lee, 1986, Heat transfer and pressure drop characteristics of an array of plates aligned at angles to the flow in a rectangular duct, International Journal of Heat and Mass Transfer, 29, 1553, 10.1016/0017-9310(86)90070-0 · DOI
- Zhang, 1989, The experimental investigation of oblique angles and interrupted plate lengths for louvered fins in compact heat exchangers, Experimental Thermal and Fluid Science, 2, 100, 10.1016/0894-1777(89)90054-X · DOI
- Lue, 1993, Experimental study on heat transfer and pressure drop characteristics in the developing region for arrays of obliquely positioned plates of nonuniform length, Experimental Thermal and Fluid Science, 7, 30, 10.1016/0894-1777(93)90078-W · doi:10.1016/0894-1777(93)90078-w
- Huang, 1993, An experimental study on heat/mass transfer and pressure drop characteristics for arrays of nonuniform plate length positioned obliquely to the flow direction, Journal of Heat Transfer, 115, 568, 10.1115/1.2910726 · doi:10.1115/1.2910726
- H.E. Beamer, D. Ghosh, K.D. Bellows, L. Huang, A.M. Jacobi, Applied CFD and experiment for automotive compact heat exchanger development, SAE Paper 980426, 1998 · DOI
- Springer, 1998, Experimental design of flowfield studies of louvered fins, Experimental Thermal and Fluid Science, 18, 258, 10.1016/S0894-1777(98)10022-5 · DOI
- Goldstein, 1995, A review of mass transfer measurements using the naphthalene sublimation technique, Experimental Thermal and Fluid Science, 10, 416, 10.1016/0894-1777(94)00071-F · DOI · Paper page
- Souza Mendes, 1991, A review of mass transfer measurements using the naphthalene sublimation technique, Experimental Thermal and Fluid Science, 4, 510, 10.1016/0894-1777(91)90031-L · DOI
- N.C. DeJong, Flow, Heat Transfer, and Pressure Drop Interactions in Louvered-Fin Arrays, Ph.D. Thesis, Dept. of Mechanical and Industrial Engineering, Univ. of Illinois at Urbana-Champaign, 1999
- Sparrow, 1980, Measurements of heat transfer and pressure drop for an array of staggered plates aligned parallel to an air flow, Journal of Heat Transfer, 102, 426, 10.1115/1.3244317 · DOI · Paper page
- Kline, 1953, Describing uncertainties in single sample experiments, Mechanical Engineering, 75, 3
- Amon, 1991, Experimental and numerical investigation of oscillatory flow and thermal phenomena in communicating channels, Experimental/Numerical Heat Transfer in Combustion and Phase Change, ASME HTD, 170, 25
- N.C. DeJong, A.M. Jacobi, Localized flow and heat transfer interactions in louvered-fin arrays, International Journal of Heat and Mass Transfer, in press · DOI
Cited by
Okbaz, A., Pınarbaşı, A., Olcay, A. B., & Aksoy, M. H. (2018) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2017.12.127 · Cited by 59
Comprehensive Study of Heat Exchangers with Louvered Fins
Erbay, L. B., Doğan, B., & Öztürk, M. M. (2017) · Heat Exchangers - Advanced Features and Applications · doi:10.5772/66472 · Cited by 31
Metadata
- Authors
- DeJong, N. C., & Jacobi, A. M.
- Venue
- Experimental Thermal and Fluid Science
- Publisher
- Elsevier BV
- Published
- 2003-03
- Volume
- 27
- Issue
- 3
- Pages
- 237-250
- ISSN
- 0894-1777
- Cited by
- 56
- References
- 3
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flow, heat transfer, and pressure drop in the near-wall region of louvered-fin arrays. https://app.cochat.ai/papers/10.1016/s0894-1777(02)00224-8
- The paper
- DeJong, N. C., & Jacobi, A. M. (2003). Flow, heat transfer, and pressure drop in the near-wall region of louvered-fin arrays. Experimental Thermal and Fluid Science. https://doi.org/10.1016/s0894-1777(02)00224-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.