CoChat

Comprehensive Study of Heat Exchangers with Louvered Fins

Open access
Erbay, Latife Berrin, Doğan, Bahadır, Öztürk, Mehmet Mete · 2017 · Heat Exchangers - Advanced Features and Applications

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index; none of the 29 sources its claims cite is checked for support yet.

Abstract

The purpose of this chapter is to describe the basic physical features and the analysis of the thermal-hydraulic performance of the louver fins. The terminology which is used widely in the field of compact heat exchanger with louvered fin is described. The flow phenomenon affected by the operating conditions and the geometric parameters of the louvered fin is examined using the flow visualization techniques found in the literature. A methodology is given to calculate the heat transfer and the friction factor. Stanton number, Colburn j-factor and friction factor are defined as a performance criteria and the variations of these criteria with respect to the Reynolds number and the geometric parameters of the louvered fin. The combinations of these dimensionless number such as area goodness factor (j/f), volume goodness factor (j/f1/3) and JF number related with the volume goodness factor are discussed in terms of overall performance criteria. Finally, the correlations of the louvered fin heat exchanger and their tabulated data was summarized.

Overview

CoChat Summary

TL;DR

This chapter reviews the thermal-hydraulic behavior of louvered-fin heat exchangers, covering flow phenomena, data-reduction methods, performance criteria, and empirical correlations. It synthesizes experimental and numerical literature to show that performance depends strongly on Reynolds number and coupled geometric parameters, so each new heat exchanger design must be evaluated individually.

Key findings

  • Louver angle and frontal air velocity determine whether flow is duct-directed or louver-directed; flow efficiency increases with louver-directed flow. Thermal performance increases up to a louver angle of 28.5° and then decreases for all considered louver pitches.
  • Average heat transfer coefficient is about 200 W/m²K at the minimum louver pitch of 0.81 mm and decreases to about 185 W/m²K at the maximum louver pitch of 1.4 mm.
  • Non-uniform louver angle patterns can enhance heat transfer: Case B showed 18% heat transfer enhancement relative to Case E at about Re = 440, but had a negative effect of 19% on the friction factor.
  • 2D CFD models overpredicted Colburn j-factor by 80% compared with experimental results, while 3D models are needed to predict both heat transfer coefficient and friction factor sensibly. The maximum reported volume goodness factor was j/f¹ᐟ³ = 0.032 for the smallest flow depth (36.0 mm), smallest fin pitch (2.00 mm), and biggest fin height (10.0 mm).

Methods

  • This is a review/synthesis chapter, not a new experimental study: it examines flow visualization, experimental, and numerical studies of louvered-fin heat exchangers from the literature.
  • It presents data-reduction methodology using the effectiveness-NTU method and the Kim and Bullard approach to determine external-side heat transfer coefficient, with performance criteria including Stanton number, Colburn j-factor, friction factor, area goodness factor (j/f), volume goodness factor (j/f¹ᐟ³), and JF number.
  • It summarizes empirical correlations for Stanton number, Colburn j-factor, and friction factor and tabulates geometrical dimensions from a large database of louvered-fin heat exchangers.

Limitations

  • The paper states that 2D numerical models are inadequate to predict heat transfer coefficient because they lack un-finned areas, while 3D models are sensible for both heat transfer coefficient and friction factor.
  • The paper states that although correlations cover wide Reynolds-number and geometric ranges, every new heat exchanger must be analyzed individually due to the complexity of combined geometric and operational effects.
  • Evident from the text: the chapter is a literature review and correlation summary rather than a new experimental or numerical dataset, so its quantitative findings depend on the cited studies and figures.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.5772/66472

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Fin geometries for plate fin heat exchangers: (a) plain triangular fin; (b) plain rectangular fin; (c) wavy fin; (d) offset strip fin; (e) multi-louver fin; (f) perforated fin [1].
Figure 1 Fin geometries for plate fin heat exchangers: (a) plain triangular fin; (b) plain rectangular fin; (c) wavy fin; (d) offset strip fin; (e) multi-louver fin; (f) perforated fin [1].CC-BY · From the PDF
Figure 2 Typical structure of a louver fin geometry [4].
Figure 2 Typical structure of a louver fin geometry [4].CC-BY · From the PDF
Figure 3 Terminology of the louvered fin [2].
Figure 3 Terminology of the louvered fin [2].CC-BY · From the PDF
Figure 4 Terminology of the louvered fin [6].
Figure 4 Terminology of the louvered fin [6].CC-BY · From the PDF
Figure 5 Possible flow direction of flow through the louvered fins.
Figure 5 Possible flow direction of flow through the louvered fins.CC-BY · From the PDF
Figure 6 Definition of the flow efficiency.
Figure 6 Definition of the flow efficiency.CC-BY · From the PDF
Figure 7 Visualization of the flow in the louvered fin array [3].
Figure 7 Visualization of the flow in the louvered fin array [3].CC-BY · From the PDF
Figure 8 Flow structure around louvered fins: (a) Re = 510, (b) Re = 820 [8].
Figure 8 Flow structure around louvered fins: (a) Re = 510, (b) Re = 820 [8].CC-BY · From the PDF
Image 9
CC-BY · From the PDF
Figure 10 Comparison of the temperature distribution of an infrared thermographs and numerical simulation results for a louvered fin array [9].
Figure 10 Comparison of the temperature distribution of an infrared thermographs and numerical simulation results for a louvered fin array [9].CC-BY · From the PDF
Figure 11 Computed velocity and temperature field for the 2-D model; Fp = 2.54 mm, Lp = 1.4 mm, L α = 25.5°. (a) Velocity, ReLp = 100, (b) Temperature, ReLp = 100, (c) Velocity, ReLp = 1600, (d) Temperature, ReLp = 1600 [18].
Figure 11 Computed velocity and temperature field for the 2-D model; Fp = 2.54 mm, Lp = 1.4 mm, L α = 25.5°. (a) Velocity, ReLp = 100, (b) Temperature, ReLp = 100, (c) Velocity, ReLp = 1600, (d) Temperature, ReLp = 1600 [18].CC-BY · From the PDF
Figure 12 Comparison of the computed 2-D model and measured friction factor and Stanton number: Fp = 2.05 mm, Lp = 1.4 mm, L α = 25.5°, Tp = 11 mm and δ = 0.05 mm [18].
Figure 12 Comparison of the computed 2-D model and measured friction factor and Stanton number: Fp = 2.05 mm, Lp = 1.4 mm, L α = 25.5°, Tp = 11 mm and δ = 0.05 mm [18].CC-BY · From the PDF
Figure 13 Comparison of computed and measured j-factor [19].
Figure 13 Comparison of computed and measured j-factor [19].CC-BY · From the PDF
Figure 14 Comparison of computed and measured f-factor [19].
Figure 14 Comparison of computed and measured f-factor [19].CC-BY · From the PDF
Figure 15 The effect of louver angle on the thermal performance of a louvered fin heat exchanger for different louver pitches [23].
Figure 15 The effect of louver angle on the thermal performance of a louvered fin heat exchanger for different louver pitches [23].CC-BY · From the PDF
Image 16
CC-BY · From the PDF
Image 17
CC-BY · From the PDF
Figure 18 Variation of the heat transfer coefficient with respect to the frontal velocity for different (a) tube pitches (Fp = 1.5 mm, Lp = 1.2 mm, L α = 26 o ) and (b) fin pitches (Tp = 9.6 mm, Lp = 1.2 mm, L α = 26 o ) [25].
Figure 18 Variation of the heat transfer coefficient with respect to the frontal velocity for different (a) tube pitches (Fp = 1.5 mm, Lp = 1.2 mm, L α = 26 o ) and (b) fin pitches (Tp = 9.6 mm, Lp = 1.2 mm, L α = 26 o ) [25].CC-BY · From the PDF
Figure 19 Schematic of a wind tunnel test [10].
Figure 19 Schematic of a wind tunnel test [10].CC-BY · From the PDF
Figure 20 Variations of j-factor and f-factor with respect to the louver angle and Reynolds number for (a) Fd = 16 mm and (b) Fd = 20 mm [10].
Figure 20 Variations of j-factor and f-factor with respect to the louver angle and Reynolds number for (a) Fd = 16 mm and (b) Fd = 20 mm [10].CC-BY · From the PDF
Figure 21 Variations of j-factor and f-factor with respect to the frontal air velocity [15].
Figure 21 Variations of j-factor and f-factor with respect to the frontal air velocity [15].CC-BY · From the PDF
Figure 22 The variation of j/f 1/3 [15].
Figure 22 The variation of j/f 1/3 [15].CC-BY · From the PDF
Figure 23 The variation of j/f 1/3 at low Reynolds number [6].
Figure 23 The variation of j/f 1/3 at low Reynolds number [6].CC-BY · From the PDF

Verification

Claims the paper makes

0 Valid · 1 Not valid · 26 Not checked · 42 Own results and interpretations

37 more claims

Create a free account to see all 69 claims and to verify the 24 references still open.

See all claims — free account
  • It may state two separate claims as one. 22
  • Probably not a substantial claim. 6

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

3 of 3

Citations

Cites

Show all 28 references

Research works printed but not linked: 4

  1. Kays W M, London A L. Compact Heat Exchangers. 3 rd ed. New York: McGraw-Hill; 1984. 335 p.
  2. Webb R L, Jung S H. Air-side performance of enhanced brazed aluminium heat exchangers. ASHRAE Transactions. 1992;98(2):391-401.
  3. Rugh J P, Pearson J T, Ramadhyani S. A study of a very compact heat exchanger used for passenger compartment heating in automobiles, in compact heat exchangers for power and process industries. In: ASME Symposium Series, HTD-Vol. 201; New York: ASME; 1992. p. 15-24.
  4. Sunden B, Svantesson J. Correlation of j-and f-factors for multilouvered heat transfer surfaces. In: 3rd UK National Heat Transfer Conference; London: South Kensington Campus; 1992. p. 805-811.

Cited by

See all 31

Metadata

Authors
Erbay, L. B., Doğan, B., & Öztürk, M. M.
Affiliations
Eskişehir Osmangazi University (TR)
Corresponding author
Erbay, Latife Berrin
Venue
Heat Exchangers - Advanced Features and Applications
Publisher
InTech
Published
2017-04-26
OpenAlex
W2608826248
Cited by
31
References
28
Citations by year
2026: 5 · 2025: 3 · 2024: 4 · 2023: 4 · 2022: 4 · 2021: 6 · 2020: 5
FWCI
4.36
Type
book chapter
Language
en
Open access
Licence
cc-by
Locations
  • InTech eBooks (publishedVersion, cc-by)
  • BiblioBoard Library Catalog (Open Research Library) (submittedVersion, cc-by)
  • Contact-less Assessment of In-vivo Body Signals Using Microwave Doppler Radar (InTech) (submittedVersion, cc-by)
Funders
Bilim, Sanayi ve Teknoloji Bakanliği
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer Mechanisms
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Boiling Studies
Keywords
louvered fins, compact heat exchangers, thermal-hydraulic performance, heat transfer, friction factor, Stanton number, Colburn j-factor, fin geometry, flow visualization

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-19, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-19 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comprehensive Study of Heat Exchangers with Louvered Fins. https://app.cochat.ai/papers/10.5772/66472
The paper
Erbay, L. B., Doğan, B., & Öztürk, M. M. (2017). Comprehensive Study of Heat Exchangers with Louvered Fins. Heat Exchangers - Advanced Features and Applications. https://doi.org/10.5772/66472

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.