Reproducibility of home, ambulatory, and clinic blood pressure: implications for the design of trials for the assessment of antihypertensive drug efficacy
The DOI matches its Crossref record.
Abstract
The objective of this work is to compare the reproducibility of blood pressure measured in the clinic (CBP), at home (HBP) and with ambulatory monitoring (ABP), and to assess its implications on the accuracy of trials for the assessment of antihypertensive drug efficacy. Study 1: The reproducibility of CBP (one visit), HBP (2 days), and ABP (24 hours) was quantified using the standard deviation of differences (SDD) between repeated measurements in 137 untreated subjects with elevated CBP. The number of subjects required in a comparative clinical trial aiming to detect a difference in the antihypertensive effect of two drugs of 10/5 mmHg (systolic/diastolic blood pressure) was calculated for each blood pressure measurement technique. Study 2: A crossover trial comparing lisinopril versus losartan was conducted using CBP, HBP and ABP in 27 hypertensive subjects. Study 1: HBP provided the lowest SDD values (6.9/4.7 mmHg for systolic/diastolic blood pressure, compared to 8.3/5.6 for ABP and 11.0/6.6 for CBP). Using HBP the number of subjects needed for a comparative trial was reduced by 30% compared to using ABP and by 60% compared to CBP. Study 2: Lisinopril was more effective than losartan in reducing CBP, ABP, and HBP. Using HBP a false positive result (type I error) was 20 times less probable (p=0.0003) compared to using ABP (p=0.005) and 40 times less probable compared to CBP (p=0.01). Only HBP ensured a clinically important difference in the antihypertensive drug effect of at least 3-4 mmHg. HBP seems to have superior reproducibility compared to both CBP and ABP. HBP monitoring can improve the accuracy of antihypertensive drug trials reducing thereby the sample size required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mancia, G., Kreutz, R., Brunström, M., Burnier, M., Grassi, G., Januszewicz, A., Muiesan, M. L., Tsioufis, K., Agabiti-Rosei, E., Algharably, E. A. E., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003480 · Cited by 3,473
Self-citationBlood pressure and its variability: classic and novel measurement techniques
Schutte, A. E., Kollias, A., & Stergiou, G. S. (2022) · Nature Reviews Cardiology · doi:10.1038/s41569-022-00690-0 · Cited by 335
Self-citationPhenotypes of masked hypertension: Isolated ambulatory, isolated home and dual masked hypertension
Stergiou, G. S., Kyriakoulis, K. G., McManus, R. J., Andreadis, E. A., Jula, A., Kollias, A., Lindroos, A., Ntineri, A., Schwartz, C., & Niiranen, T. J. (2020) · Journal of Hypertension · doi:10.1097/hjh.0000000000002270 · Cited by 24
Self-citationHer, A.-Y., Kim, Y. H., Rim, S.-J., Kim, J.-Y., Choi, E.-Y., Min, P.-K., Lee, B.-K., Hong, B.-K., & Kwon, H. M. (2014) · Anadolu Kardiyoloji Dergisi/The Anatolian Journal of Cardiology · doi:10.5152/akd.2014.5119 · Cited by 12
Metadata
- Authors
- Stergiou, G.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-11
- Volume
- 14
- Issue
- 11
- Pages
- A38
- ISSN
- 0895-7061 (ISSN-L)
- OpenAlex
- W1886903245
- Cited by
- 27
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility of home, ambulatory, and clinic blood pressure: implications for the design of trials for the assessment of antihypertensive drug efficacy. https://app.cochat.ai/papers/10.1016/s0895-7061(01)01505-9
- The paper
- Stergiou, G. (2001). Reproducibility of home, ambulatory, and clinic blood pressure: implications for the design of trials for the assessment of antihypertensive drug efficacy. American Journal of Hypertension. https://doi.org/10.1016/s0895-7061(01)01505-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.