Home Self-Monitoring of Blood Pressure Is Fully Automated Oscillometric Technique as Good as Conventional Stethoscopic Technique?
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Home blood pressure (HBP) measurement is becoming increasingly popular as an additional source of information for the practicing physician. Whether HBP measured with a fully automated oscillometric device (oHBP) is more reliable than HBP measured with an aneroid sphygmomanometer and a stethoscope (sHBP) remains unclear. We compared sHBP with oHBP using as a reference method daytime ambulatory blood pressure (ABP), as this is believed to be a better index of an individual's overall level of pressure. Forty-six hypertensive patients measuring HBP with aneroid devices were retrained by a standard 30 min protocol that included training in the technique of measurement, checking patients' devices, and testing patients' performance in stethoscopic measurement. Patients were randomized to measure for 2 weeks either sHBP using their own calibrated aneroid devices or oHBP using a validated fully automated oscillometric device (Omron HEM-705CP). Then 24 h ABP monitoring was performed (SpaceLabs 90207) and patients crossed over for a second 2 week period by using the alternative HBP measurement technique. Mean sHBP was not different from mean oHBP, and there was a close correlation between them (r = 0.82/0.76 for systolic/diastolic BP, P < .001). Daytime ABP was not different from oHBP or sHBP and was closely related to both of them (oHBP, r = 0.59/0.72 systolic/diastolic BP, P < .001; sHBP, 0.50/0.65, P < .001). Age was significantly related with diastolic ABP-sHBP difference (r = 0.33, P < .05). These results suggest that HBP measured with validated fully automated oscillometric devices is equally reliable in predicting average ABP as that measured with calibrated aneroid sphygmomanometers used by very carefully trained patients. In clinical practice, HBP monitoring by using reliable automated devices is probably more feasible than to achieve a high standard of stethoscopic HBP measuring technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Pickering, T. G., Miller, N. H., Ogedegbe, G., Krakoff, L. R., Artinian, N. T., & Goff, D. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.189010 · Cited by 668
Agarwal, R., Bills, J. E., Hecht, T. J. W., & Light, R. P. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.160911 · Cited by 430
Hypertension in South African adults: results from the Demographic and Health Survey, 1998
Steyn, K., Gaziano, T. A., Bradshaw, D., Laubscher, R., & Fourie, J. (2001) · Journal of Hypertension · doi:10.1097/00004872-200110000-00004 · Cited by 225
Asmar, R., & Zanchetti, A. (2000) · Journal of Hypertension · doi:10.1097/00004872-200018050-00001 · Cited by 213
Self-monitoring of blood pressure at home: how many measurements are needed?
Stergiou, G. S., Skeva, I. I., Zourbaki, A. S., & Mountokalakis, T. D. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816060-00002 · Cited by 212
Self-citation
Metadata
- Authors
- Stergiou, G.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-04
- Volume
- 10
- Issue
- 4
- Pages
- 428-433
- ISSN
- 0895-7061 (ISSN-L)
- OpenAlex
- W2044029245
- Cited by
- 57
- References
- 1
- FWCI
- 3.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.