CoChat

Relations of Doppler Stroke Volume and Its Components to Left Ventricular Stroke Volume in Normotensive and Hypertensive American Indians The Strong Heart Study

Open access
Devereux, R · 1997 · American Journal of Hypertension
Cited by 95

The DOI matches its Crossref record.

Abstract

Doppler echocardiographic measurement of time-velocity integral of blood flow across the aortic annulus ("stroke distance") or of stroke volume (SV) have been proposed as noninvasive measures of cardiac pump performance that could elucidate the hemodynamics of hypertension. To evaluate the performance of these measures of hemodynamic volume load in a population with a wide range of body build and other characteristics, we obtained technically adequate imaging and Doppler echocardiograms in 1,935 of 2,212 (87%) American Indian Strong Heart Study participants, without mitral regurgitation or segmental left ventricular (LV) dysfunction, in Arizona, Oklahoma, and South/North Dakota. The subjects ranged widely in age (48 to 81 years) and body mass index (17.0 to 62.6 kg/m2); 65% were women; 1,161 were normotensive and 774 were hypertensive. As a reference standard, LV and stroke volumes were calculated from LV internal dimensions by the Teichholz method. Doppler SVs were moderately related to LV SVs (r = 0.63), but Doppler SV was slightly lower in both normotensive (mean = 69.8 and 72.9 mL, respectively) and hypertensive subjects (71.1 v 73.6 mL). Aortic stroke distance was less closely related than was aortic annular area to LV SV (r = 0.34 v 0.40, P < .001). Aortic annular area (r = 0.44) but not stroke distance (r = 0.04) was moderately correlated with body surface area. Stroke distance was inversely related to annular area (r = -0.29) and in subjects stratified by aortic annular diameter 1.6 to 1.9, 2.0 to 2.1, and 2.3 to 2.9 cm, mean LV SV increased from 67 to 74 to 80 mL, but average stroke distance fell from 22.8 to 21.6 to 20.1 cm. Stroke distance also failed to identify gender differences in LV SV but did identify that due to obesity. Thus Doppler SV closely parallels independently measured LV SV but slightly underestimates SV in both normotensive and hypertensive adults, whereas aortic stroke distance yields misleading comparisons between genders or individuals of different body sizes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0895-7061(97)00059-9

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 95

Metadata

Authors
Devereux, R.
Venue
American Journal of Hypertension
Published
1997-06
Volume
10
Issue
6
Pages
619-628
ISSN
0895-7061 (ISSN-L)
OpenAlex
W2153515775
Cited by
95
References
0
FWCI
3.25
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Relations of Doppler Stroke Volume and Its Components to Left Ventricular Stroke Volume in Normotensive and Hypertensive American Indians The Strong Heart Study. https://app.cochat.ai/papers/10.1016/s0895-7061(97)00059-9
The paper
Devereux, R. (1997). Relations of Doppler Stroke Volume and Its Components to Left Ventricular Stroke Volume in Normotensive and Hypertensive American Indians The Strong Heart Study. American Journal of Hypertension. https://doi.org/10.1016/s0895-7061(97)00059-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.