Limited Reproducibility of Circadian Variation in Blood Pressure Dippers and Nondippers
The DOI matches its Crossref record.
Abstract
The relation between blood pressure (BP) variation and hypertensive organ damage is controversial. The reproducibility of the circadian variation pattern acceptable as the standard for discriminating between "dippers" and "nondippers" has not yet been evaluated. We evaluated the reproducibility of "dipper" and "nondipper" patterns in essential hypertensives by monitoring BP for 48 h. Noninvasive ambulatory BP and heart rate (HR) monitoring for 48 h every 30 min were performed in 253 untreated patients with mild-to-moderate essential hypertension. Mean daytime (awake) and nighttime (sleeping) systolic BP, diastolic BP, and HR values were analyzed by reviewing the patients' diaries. Patients were divided into two groups by presence (dippers) and absence (nondippers) of a reduction of both systolic and diastolic BP during the night of > 10% of the daytime pressure. A subject who was a dipper on day 1 remained a dipper on day 2 in 41% (n = 103, DD group) and changed to nondipper in 16% (n = 41, DN group). A subject who was a nondipper on day 1 remained a nondipper on day 2 in 30% (n = 75, NN group) and changed to a dipper in 13% (n = 34, ND group). Our findings indicate that there is a high risk of false-positive or false-negative results when 24-h recordings are used to identify dipper and nondipper profiles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Prognostic accuracy of day versus night ambulatory blood pressure: a cohort study
Boggia, J., Li, Y., Thijs, L., Hansen, T. W., Kikuya, M., Björklund-Bodegård, K., Richart, T., Ohkubo, T., Kuznetsova, T., Torp-Pedersen, C., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61538-4 · Cited by 887
Manning, G., Rushton, L., Donnelly, R., & Millar-Craig, M. W. (2000) · American Journal of Hypertension · doi:10.1016/s0895-7061(00)00261-2 · Cited by 138
Cuspidi, C., Meani, S., Salerno, M., Valerio, C., Fusi, V, Severgnini, B., Lonati, L., Magrini, F., & Zanchetti, A. (2004) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001681 · Cited by 79
Taylor, K. S., Heneghan, C. J., Stevens, R. J., Adams, E. C., Nunan, D., & Ward, A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0126375 · Cited by 48
Metadata
- Authors
- Mochizuki, Y.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-04
- Volume
- 11
- Issue
- 4
- Pages
- 403-409
- ISSN
- 0895-7061 (ISSN-L)
- OpenAlex
- W2164771986
- Cited by
- 163
- References
- 0
- FWCI
- 6.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Limited Reproducibility of Circadian Variation in Blood Pressure Dippers and Nondippers. https://app.cochat.ai/papers/10.1016/s0895-7061(97)00497-4
- The paper
- Mochizuki, Y. (1998). Limited Reproducibility of Circadian Variation in Blood Pressure Dippers and Nondippers. American Journal of Hypertension. https://doi.org/10.1016/s0895-7061(97)00497-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.