Reproducibility of nocturnal blood pressure fall in early phases of untreated essential hypertension: a prospective observational study
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
A number of studies have shown that a smaller than normal nocturnal blood pressure (BP) decrease is associated with cardiovascular disease. However, no large prospective studies have examined the reliability of nocturnal dipping within individuals. The aim of our study was to investigate the short-term variability of nocturnal BP fall in a large cohort of patients with recently diagnosed essential hypertension. In all, 414 uncomplicated never treated hypertensive patients referred to our outpatient hypertension hospital clinic (mean age 46+/-12 years; 257 M, 157 F) prospectively underwent: (1). repeated clinic BP measurements; (2). routine examinations recommended by WHO/ISH guidelines; and (3). ambulatory BP monitoring (ABPM) twice within a 4-week period. Dipping pattern was defined as a reduction in the average systolic and diastolic BP at night greater than 10% compared to average daytime values. Overall, 311 patients (75.1%) showed no change in their diurnal variations in BP. Of the 278 patients who had a dipping pattern on the first ABPM, 219 (78.7%) confirmed this type of profile on the second ABPM, while 59 (21.3%) showed a nondipping pattern. Among 37 dipper patients with >20% of nocturnal systolic BP decrease (extreme dippers), only 16 (43.2%) had this marked fall in BP on the second ABPM. Of the 136 patients who had a nondipping pattern on the first ABPM, 92 (67.6%) confirmed their initial profile on the second ABPM, while 44 (32.4%) did not. Patients with reproducible nondipping profile were older (48+/-12 years) than those with reproducible dipping profile (44+/-12 years, P<0.05). These findings indicate that: (1). short-term reproducibility of nocturnal fall in BP in untreated middle-aged hypertensives is rather limited: overall, one-fourth of patients changed their initial dipping patterns when they were studied again after a few weeks; (2). this was particularly true for extreme dipping and nondipping patterns; (3). abnormalities in nocturnal BP fall, assessed by a single ABPM, cannot be taken as independent predictors of increased cardiovascular risk.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The reproducibility of specific diurnal BP patterns identified by 24 h ABPM, including nocturnal BP dipping and the morning BP surge, is also less than optimal46–49.”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [46]
Citations
Cites
Ambulatory blood pressure. An independent predictor of prognosis in essential hypertension.
Verdecchia, P., Porcellati, C., Schillaci, G., Borgioni, C., Ciucci, A., Battistelli, M., Guerrieri, M., Gatteschi, C., Zampi, I., Santucci, A., et al. (1994) · Hypertension · doi:10.1161/01.hyp.24.6.793 · Cited by 1,676
Circadian blood pressure changes and left ventricular hypertrophy in essential hypertension.
Verdecchia, P., Schillaci, G., Guerrieri, M., Gatteschi, C., Benemio, G., Boldrini, F., & Porcellati, C. (1990) · Circulation · doi:10.1161/01.cir.81.2.528 · Cited by 1,224
Prognostic value of 24-hour blood pressure variability
Frattola, A., Parati, G., Cuspidi, C., Albini, F., & Mancia, G. (1993) · Journal of Hypertension · doi:10.1097/00004872-199310000-00019 · Cited by 659
Self-citationPrognostic Value of Ambulatory Blood Pressure: Current Evidence and Clinical Implications
Verdecchia, P. (2000) · Hypertension · doi:10.1161/01.hyp.35.3.844 · Cited by 621
Kario, K., Matsuo, T., Kobayashi, H., Imiya, M., Matsuo, M., & Shimada, K. (1996) · Hypertension · doi:10.1161/01.hyp.27.1.130 · Cited by 617
Prognostic Significance of Blood Pressure and Heart Rate Variabilities: The Ohasama Study
Kikuya, M., Hozawa, A., Ohokubo, T., Tsuji, I., Michimata, M., Matsubara, M., Ota, M., Nagai, K., Araki, T., Satoh, H., et al. (2000) · Hypertension · doi:10.1161/01.hyp.36.5.901 · Cited by 609
Accuracy of the SpaceLabs 90207 determined by the British Hypertension Society Protocol
O??Brien, E., Mee, F., Atkins, N., & O??Malley, K. (1991) · Journal of Hypertension · doi:10.1097/00004872-199106000-00016 · Cited by 451
Sander, D., Kukla, C., Klingelhöfer, J., Winbeck, K., & Conrad, B. (2000) · Circulation · doi:10.1161/01.cir.102.13.1536 · Cited by 405
The clinical significance of diurnal blood pressure variations. Dippers and nondippers.
Pickering, T. G. (1990) · Circulation · doi:10.1161/01.cir.81.2.700 · Cited by 373
Diurnal Variations of Blood Pressure and Microalbuminuria in Essential Hypertension
Bianchi, S., Bigazzi, R., Baldari, G., Sgherri, G., & Campese, V. M. (1994) · American Journal of Hypertension · doi:10.1093/ajh/7.1.23 · Cited by 369
Research works printed but not linked: 1
- Verdecchia P, Schillaci G, Porcellati G . Dippers versus nondippers. J Hypertens 1991; 9 (Suppl 2): S42–S44.
Cited by
Blood pressure and its variability: classic and novel measurement techniques
Schutte, A. E., Kollias, A., & Stergiou, G. S. (2022) · Nature Reviews Cardiology · doi:10.1038/s41569-022-00690-0 · Cited by 335
Ambulatory Blood Pressure Monitoring and Risk of Cardiovascular Disease: A Population Based Study
HANSEN, T., JEPPESEN, J., RASMUSSEN, S., IBSEN, H., & TORPPEDERSEN, C. (2006) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.09.018 · Cited by 249
“It is well known that the classification of subjects into dippers and nondippers may change over time.(28) The larger number of BP measurements undoubtedly contributed to the advantage of ambulatory BP.”
BackgroundParati, G., Bilo, G., Kollias, A., Pengo, M., Ochoa, J. E., Castiglioni, P., Stergiou, G. S., Mancia, G., Asayama, K., Asmar, R., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003363 · Cited by 220
Davidson, M. B., Hix, J. K., Vidt, D. G., & Brotman, D. J. (2006) · Archives of Internal Medicine · doi:10.1001/archinte.166.8.846 · Cited by 223
“Also, multiple assessments of ambulatory BPs were not performed.(43) However, intraindividual variation in dipping status would probably tend to weaken our findings.”
BackgroundAdrenergic, Metabolic, and Reflex Abnormalities in Reverse and Extreme Dipper Hypertensives
Grassi, G., Seravalle, G., Quarti-Trevano, F., Dell'Oro, R., Bombelli, M., Cuspidi, C., Facchetti, R., Bolla, G., & Mancia, G. (2008) · Hypertension · doi:10.1161/hypertensionaha.108.116368 · Cited by 214
Self-citation
Metadata
- Authors
- Cuspidi, C., Meani, S., Salerno, M., Valerio, C., Fusi, V, Severgnini, B., Lonati, L., Magrini, F., & Zanchetti, A.
- Affiliations
- University of Milan (IT)
- Corresponding author
- Cuspidi, C
- Venue
- Journal of Human Hypertension
- Published
- 2004-01-29
- Volume
- 18
- Issue
- 7
- Pages
- 503-509
- ISSN
- 0950-9240 (ISSN-L)
- 1476-5527
- OpenAlex
- W2047003127
- Cited by
- 79
- References
- 33
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 2 · 2023: 1 · 2022: 2 · 2021: 1 · 2020: 2 · 2018: 4 · 2017: 3 · 2016: 3 · 2015: 7 · 2014: 2 · 2013: 4 · 2012: 5
- FWCI
- 4.14
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Journal of Human Hypertension (publishedVersion)
- PubMed (publishedVersion)
- BOA (University of Milano-Bicocca) (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Keywords
- essential hypertension, nocturnal blood pressure dipping, reproducibility, ambulatory blood pressure monitoring, untreated hypertensive patients, cardiovascular risk, diurnal blood pressure variation, middle-aged adults
- MeSH terms
- Adult, Aging, Blood Pressure, Circadian Rhythm, Diastole, Female, Humans, Hypertension, Male, Middle Aged, Prospective Studies, Systole, Reproducibility of Results, Cohort Studies, Blood Pressure Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility of nocturnal blood pressure fall in early phases of untreated essential hypertension: a prospective observational study. https://app.cochat.ai/papers/10.1038/sj.jhh.1001681
- The paper
- Cuspidi, C., Meani, S., Salerno, M., Valerio, C., Fusi, V, Severgnini, B., Lonati, L., Magrini, F., & Zanchetti, A. (2004). Reproducibility of nocturnal blood pressure fall in early phases of untreated essential hypertension: a prospective observational study. Journal of Human Hypertension. https://doi.org/10.1038/sj.jhh.1001681
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.