CoChat

Measurement variation among 12 electronic home blood pressure monitors

Yarows, S. A., Brook, R. D. · 2000 · American Journal of Hypertension
Cited by 51

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Although there are AAMI and BHS standards for accuracy of electronic home electronic blood pressure monitors (HBPM), patient composition differences and differences in manufacturer's algorithm for calculation of the systolic and diastolic measurement may result in measurement differences between monitors. The aim of this study was the measurement of differences among HBPM. Paired comparisons were performed between the Omron 712c electronic home monitor and each of 12 other HBPM (Sunbeam 7654, Sunbeam 7623, Omron 711, Omron 432c, A&D-UA767, Lumiscope 1085M, Omron 725CIC, Assure A30, Lumiscope 1083N, Omron 815, Omron 605, and Assure BD-W20), in addition to comparison to the auscultatory method by trained observers. Measurements were made in normotensive subjects in an ambulatory setting. The main outcome measures were systolic and diastolic blood pressure measurements. All of the HBPM, except for the Sunbeam 7654 and the Assure A30/ BD-W20 (wrist) models, demonstrated small differences of <4/4 mm Hg for systolic/diastolic measurements with pulse measurement differences of <3 beats/min. These differences were less than the differences previously reported for office BP auscultation of 6/5-10 mm Hg for systolic/diastolic measurements. The Omron 712c, passing previous AAMI and BHS standards, measured the systolic reading within 2 mm Hg of auscultatory mercury or aneroid measurement and under-measured the diastolic by 6-9 mm Hg. Differences in the patient composition studied could account for the difference. The wrist and finger manometers performed clinically similar to the Omron 712c, except for the Assure BD-W20, which overmeasured the diastolic by 7 mm Hg. It is concluded that the small differences among the various HBPM, which are less than those in clinical office auscultation, should encourage greater use of electronic manometers in the office and at home.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0895-7061(99)00182-x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 51

Metadata

Authors
Yarows, S. A., & Brook, R. D.
Venue
American Journal of Hypertension
Published
2000-03-01
Volume
13
Issue
3
Pages
276-282
ISSN
  • 0895-7061 (ISSN-L)
  • 1941-7225
OpenAlex
W1997765765
Cited by
51
References
2
FWCI
2.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement variation among 12 electronic home blood pressure monitors. https://app.cochat.ai/papers/10.1016/s0895-7061(99)00182-x
The paper
Yarows, S. A., & Brook, R. D. (2000). Measurement variation among 12 electronic home blood pressure monitors. American Journal of Hypertension. https://doi.org/10.1016/s0895-7061(99)00182-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.