Cited by 155Non-Invasive Vital Sign MonitoringWireless Body Area NetworksAdvanced Sensor and Energy Harvesting Materials

Wearable Devices for Precision Medicine and Health State Monitoring

Jeong, In cheol, Bychkov, David, Searson, Peter C.·2019·IEEE Transactions on Biomedical Engineering

Abstract

Wearable technologies will play an important role in advancing precision medicine by enabling measurement of clinically-relevant parameters describing an individual's health state. The lifestyle and fitness markets have provided the driving force for the development of a broad range of wearable technologies that can be adapted for use in healthcare. Here we review existing technologies currently used for measurement of the four primary vital signs: temperature, heart rate, respiration rate, and blood pressure, along with physical activity, sweat, and emotion. We review the relevant physiology that defines the measurement needs and evaluate the different methods of signal transduction and measurement modalities for the use of wearables in healthcare.

Integrity signals

Registry

Crossref · 10.1109/tbme.2018.2871638

Cites

266 of 266 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • IWMDs provide predictive bio-analysis, timely treatment intervention, and improved drug efficacy, thereby promoting precision medicine.

    “Through tracking physiological and pathological factors and delivering therapeutic agents acting in an on-demand manner, IWMDs have become indispensable in providing predictive bio-analysis, timely treatment intervention, and improved drug efficacy, thereby promoting precision medicine (cheol Jeong et al. 2018; Tan et al. 2022).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Jeong, I. C., Bychkov, D., & Searson, P. C.
Affiliations
  • Johns Hopkins University (US)
  • University of California, Los Angeles (US)
Venue
IEEE Transactions on Biomedical Engineering
Published
2019-05
Volume
66
Issue
5
Pages
1242-1258
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2894098752
Cited by
155
References
266
Citations by year
2026: 5 · 2025: 21 · 2024: 18 · 2023: 30 · 2022: 32 · 2021: 18 · 2020: 24 · 2019: 7
FWCI
4.90
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
Johns Hopkins University
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
Keywords
wearable devices, precision medicine, health state monitoring, vital signs, body temperature, heart rate, respiration rate, blood pressure, physical activity monitoring, sweat monitoring, emotion monitoring, signal transduction, physiological measures
MeSH terms
Smartphone, Wearable Electronic Devices, Blood Pressure Determination, Electrocardiography, Emotions, Humans, Monitoring, Physiologic, Sweat, Photoplethysmography, Telemedicine, Vital Signs, Precision Medicine

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review