Quantum detection by current carrying superconducting film
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Femtosecond spectroscopy of electron-electron and electron-phonon energy relaxation in Ag and Au
Groeneveld, R. H. M., Sprik, R., & Lagendijk, A. (1995) · Physical Review B · doi:10.1103/physrevb.51.11433 · Cited by 672
Low temperature scanning electron microscopy of superconducting thin films and Josephson junctions
Gross, R., & Koelle, D. (1994) · Reports on Progress in Physics · doi:10.1088/0034-4885/57/7/001 · Cited by 137
Semenov, A. D., Nebosis, R. S., Gousev, Y. P., Heusinger, M., & Renk, K. F. (1995) · Physical review. B, Condensed matter · doi:10.1103/physrevb.52.581 · Cited by 123
Self-citationUltimate quantum efficiency of a superconducting hot-electron photodetector
Ilin, K., Milostnaya, I., Verevkin, A., Gol'tsman, G. N., Gershenzon, E. M., & Sobolewski, R. (1998) · Applied Physics Letters · doi:10.1063/1.122942 · Cited by 53
Self-citationPhase-slip centers in superconducting aluminum strips
Stuivinga, M., Ham, C. L. G., Klapwijk, T. M., & Mooij, J. E. (1983) · Journal of Low Temperature Physics · doi:10.1007/bf00683998 · Cited by 39
Nonthermal mixing mechanism in a diffusion-cooled hot-electron detector
Semenov, A. D., & Gol'tsman, G. N. (2000) · Journal of Applied Physics · doi:10.1063/1.371890 · Cited by 19
Self-citation
Cited by
Picosecond superconducting single-photon optical detector
Gol’tsman, G. N., Okunev, O., Chulkova, G., Lipatov, A., Semenov, A., Smirnov, K., Voronov, B., Dzardanov, A., Williams, C., & Sobolewski, R. (2001) · Applied Physics Letters · doi:10.1063/1.1388868 · Cited by 1,597
Self-citationDetecting single infrared photons with 93% system efficiency
Marsili, F., Verma, V. B., Stern, J. A., Harrington, S., Lita, A. E., Gerrits, T., Vayshenker, I., Baek, B., Shaw, M. D., Mirin, R. P., et al. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.13 · Cited by 1,202
Superconducting nanowire single-photon detectors: physics and applications
Natarajan, C. M., Tanner, M. G., & Hadfield, R. H. (2012) · Superconductor Science and Technology · doi:10.1088/0953-2048/25/6/063001 · Cited by 970
Superconducting nanowire photon-number-resolving detector at telecommunication wavelengths
Divochiy, A., Marsili, F., Bitauld, D., Gaggero, A., Leoni, R., Mattioli, F., Korneev, A., Seleznev, V., Kaurova, N., Minaeva, O., et al. (2008) · Nature Photonics · doi:10.1038/nphoton.2008.51 · Cited by 406
“23 ) close to unity in the PND, because the noisy quasi-particle multiplication proces”
BackgroundSelf-citationKinetic-inductance-limited reset time of superconducting nanowire photon counters
Kerman, A. J., Dauler, E. A., Keicher, W. E., Yang, J. K. W., Berggren, K. K., Gol’tsman, G., & Voronov, B. (2006) · Applied Physics Letters · doi:10.1063/1.2183810 · Cited by 403
Self-citation
Metadata
- Authors
- Semenov, A. D., Gol’tsman, G. N., & Korneev, A. A.
- Venue
- Physica C: Superconductivity
- Publisher
- Elsevier BV
- Published
- 2001-04
- Volume
- 351
- Issue
- 4
- Pages
- 349-356
- ISSN
- 0921-4534 (ISSN-L)
- OpenAlex
- W2046056747
- Cited by
- 330
- References
- 6
- FWCI
- 5.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.