The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
On the measurement of thin liquid overlayers with the quartz-crystal microbalance
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
Verwendung von Schwingquarzen zur W�gung d�nner Schichten und zur Mikrow�gung
Sauerbrey, G. (1959) · Zeitschrift f�r Physik · doi:10.1007/bf01337937 · Cited by 9,653
The use of quarts oscillators for weighing thin layers and for microweighing
Sauerbrey, G., & Sauerbrey, G. (1959) · Medical Entomology and Zoology · Cited by 4,456
The interaction of water with solid surfaces: Fundamental aspects
Thiel, P. A., & Madey, T. E. (1987) · Surface Science Reports · doi:10.1016/0167-5729(87)90001-x · Cited by 2,411
Rodahl, M., Höök, F., Krozer, A., Brzezinski, P., & Kasemo, B. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145396 · Cited by 1,296
Self-citationFrequency shifts of piezoelectric quartz crystals immersed in organic liquids
NOMURA, T., & OKUHARA, M. (1982) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)95290-0 · Cited by 347
Muratsugu, M., Ohta, F., Miya, Y., Hosokawa, T., Kurosawa, S., Kamo, N., & Ikeda, H. (1993) · Analytical Chemistry · doi:10.1021/ac00068a036 · Cited by 233
Watts, E. T., Krim, J., & Widom, A. (1990) · Physical Review B · doi:10.1103/physrevb.41.3466 · Cited by 165
Computations for the Nano-Scale
(1993) · Springer eBooks · doi:10.1007/978-94-011-1956-6 · Cited by 63
Cited by
Voinova, M. V., Rodahl, M., Jonson, M., & Kasemo, B. (1999) · Physica Scripta · doi:10.1238/physica.regular.059a00391 · Cited by 1,587
Self-citationBuildup Mechanism for Poly(l-lysine)/Hyaluronic Acid Films onto a Solid Surface
Picart, C., Lavalle, P., Hubert, P., Cuisinier, F. J. G., Decher, G., Schaaf, P., & Voegel, J.-C. (2001) · Langmuir · doi:10.1021/la010848g · Cited by 695
Piezoelectric MEMS sensors: state-of-the-art and perspectives
Tadigadapa, S., & Mateti, K. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/9/092001 · Cited by 581
Cho, N.-J., Frank, C. W., Kasemo, B., & Höök, F. (2010) · Nature Protocols · doi:10.1038/nprot.2010.65 · Cited by 542
Self-citationHöök, F., Rodahl, M., Kasemo, B., & Brzezinski, P. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.21.12271 · Cited by 483
Self-citation
Metadata
- Authors
- Rodahl, M., & Kasemo, B.
- Venue
- Sensors and Actuators A: Physical
- Publisher
- Elsevier BV
- Published
- 1996-06
- Volume
- 54
- Issue
- 1-3
- Pages
- 448-456
- ISSN
- 0924-4247 (ISSN-L)
- OpenAlex
- W2172695216
- Cited by
- 345
- References
- 9
- FWCI
- 4.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On the measurement of thin liquid overlayers with the quartz-crystal microbalance. https://app.cochat.ai/papers/10.1016/s0924-4247(97)80002-7
- The paper
- Rodahl, M., & Kasemo, B. (1996). On the measurement of thin liquid overlayers with the quartz-crystal microbalance. Sensors and Actuators A: Physical. https://doi.org/10.1016/s0924-4247(97)80002-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.