The DOI matches its Crossref record.
Quartz crystal microbalance for the detection of microgram quantities of human serum albumin: relationship between the frequency change and the mass of protein adsorbed
Abstract
We have developed a piezoelectric immunosensor for the detection of microalbumin. Human serum albumin (HSA) in the range 0.1-100 micrograms mL-1 could be detected using a flow cell; the immunosensor is sensitive enough to monitor levels of albuminuria. The immunosensor did not respond to bovine serum albumin, only to HSA, implying that the specificity for HSA was high. We investigated the relationship between the frequency change (delta F) and adsorption per unit area of piezoelectrically active quartz crystal (delta M). delta M was estimated with radioisotope-labeled anti-HSA or HSA. When anti-HSA was adsorbed onto the surface of the crystal or HSA was bound to anti-HSA supported by the crystal, values of magnitude of delta F/delta M were larger than the value predicted from theory (Sauerbrey's equation). Furthermore, magnitude of delta F/delta M for HSA was larger than that for anti-HSA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Höök, F., Kasemo, B., Nylander, T., Fant, C., Sott, K., & Elwing, H. (2001) · Analytical Chemistry · doi:10.1021/ac0106501 · Cited by 1,162
Commercial quartz crystal microbalances – theory and applications
O’Sullivan, C. K., & Guilbault, G. G. (1999) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(99)00040-8 · Cited by 658
Overview of Piezoelectric Biosensors, Immunosensors and DNA Sensors and Their Applications
Pohanka, M. (2018) · Materials · doi:10.3390/ma11030448 · Cited by 384
Aponte, V. M., Finch, D. S., & Klaus, D. M. (2006) · Life Sciences · doi:10.1016/j.lfs.2006.04.007 · Cited by 51
Nanofiber‐Based Chemical Sensors
Andrady, A. L. (2022) · Applications of Polymer Nanofibers · doi:10.1002/9781119267713.ch4 · Cited by 5
Metadata
- Authors
- Muratsugu, M., Ohta, F., Miya, Y., Hosokawa, T., Kurosawa, S., Kamo, N., & Ikeda, H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1993-10-15
- Volume
- 65
- Issue
- 20
- Pages
- 2933-2937
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1995311659
- Cited by
- 233
- References
- 0
- FWCI
- 4.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quartz crystal microbalance for the detection of microgram quantities of human serum albumin: relationship between the frequency change and the mass of protein adsorbed. https://app.cochat.ai/papers/10.1021/ac00068a036
- The paper
- Muratsugu, M., Ohta, F., Miya, Y., Hosokawa, T., Kurosawa, S., Kamo, N., & Ikeda, H. (1993). Quartz crystal microbalance for the detection of microgram quantities of human serum albumin: relationship between the frequency change and the mass of protein adsorbed. Analytical Chemistry. https://doi.org/10.1021/ac00068a036
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.