The culture of neurons on silicon
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Silicon is bioinert as a material, permitting cell growth and remaining stable for long periods of implantation without causing adverse tissue reactions.
“Silicon is bioinert as a material, permitting cell growth (Bayliss et al., 1999) and remaining stable for long periods of implantation without causing adverse tissue reactions (Shin et al., 2019).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Bayliss et al., 1999
Cites
Topographical control of cells
Curtis, A. S. G., & Wilkinson, C. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00144-0 · Cited by 1,406 · see citing works
Canham, L., & Inspec (1997) · Cited by 985 · see citing works
Bioactive silicon structure fabrication through nanoetching techniques
Canham, L. (1995) · Advanced Materials · doi:10.1002/adma.19950071215 · Cited by 625 · see citing works
Fluoride-Induced Hierarchical Ordering of Mesoporous Silica in Aqueous Acid-Syntheses
Schmidt‐Winkel, P., Yang, P., Margolese, D. I., Chmelka, B. F., & Stucky, G. D. (1999) · Advanced Materials · doi:10.1002/(sici)1521-4095(199903)11:4 · Cited by 179 · see citing works
Silicon-neuron junction: capacitive stimulation of an individual neuron on a silicon chip.
Fromherz, P., & Stett, A. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.1670 · Cited by 167 · see citing works
Drott, J., Lindström, K., Rosengren, L., et al. (1997) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/7/1/004 · Cited by 155 · see citing works
Cell attachment on silicon nanostructures
Turner, S., Kam, L. C., Isaacson, M. S., et al. (1997) · Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · doi:10.1116/1.589742 · Cited by 128 · see citing works
Siemiatycki, J., Fritschi, L., Nadon, L., & Gérin, M. (1997) · American Journal of Industrial Medicine · doi:10.1002/(sici)1097-0274(199703)31:3 · Cited by 106 · see citing works
Heini, P. (1996) · Injury · doi:10.1016/0020-1383(96)83793-4 · Cited by 102 · see citing works
Canham, L., Reeves, C. L., Loni, A., et al. (1997) · Thin Solid Films · doi:10.1016/s0040-6090(96)09534-x · Cited by 90 · see citing works
The semiconductor elements arsenic and indium induce apoptosis in rat thymocytes
Bustamante, J., Dock, L., Vahter, M., et al. (1997) · Toxicology · doi:10.1016/s0300-483x(96)03607-4 · Cited by 89 · see citing works
Nature of the Silicon-Animal Cell Interface
Bayliss, S. C., Buckberry, L. D., Harris, P. J. F., et al. (2000) · Journal of Porous Materials · doi:10.1023/a:1009686704506 · Cited by 85 · see citing works
Self-citationMiniaturization of potentiometric sensors using porous silicon microtechnology
Schöning, M. J., Ronkel, F., Crott, M., Thust, M., Schultze, J. W., Kordos, P., & Luth, H. (1997) · Electrochimica Acta · doi:10.1016/s0013-4686(97)00172-2 · Cited by 83 · see citing works
Rat sciatic nerve regeneration through a micromachined silicon chip
Zhao, Q., Drott, J., Laurell, T., Wallman, L., Lindström, K., Bjursten, L. M., Lundborg, G., Montelius, L., & Danielsen, N. (1997) · Biomaterials · doi:10.1016/s0142-9612(96)00112-3 · Cited by 67 · see citing works
Phosphate and cell growth on nanostructured semiconductors
Bayliss, S. C., Harris, P. J. F., Buckberry, L. D., et al. (1997) · Journal of Materials Science Letters · doi:10.1023/a:1018581014416 · Cited by 49 · see citing works
Self-citationTwo-way silicon-neuron interface by electrical induction
Stett, A., Müller, B., & Fromherz, P. (1997) · Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics · doi:10.1103/physreve.55.1779 · Cited by 43 · see citing works
Kubo, K., Tsukasa, N., UEHAR, M., et al. (1997) · Journal of Oral Rehabilitation · doi:10.1046/j.1365-2842.1997.00462.x · Cited by 28 · see citing works
Richter, E., Fuhr, G., Müller, T., Shirley, S. G., Rogaschewski, S., Reimer, K., & Dell, C. (1996) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00058719 · Cited by 22 · see citing works
Recent progress in micromachining technology and application in implantable biomedical systems
Najafi, K. (2002) · doi:10.1109/mhs.1995.494211 · Cited by 17 · see citing works
High‐resolution confocal microscopy using synchrotron radiation
van der Oord, C. J. R., Jones, G. R., Shaw, D. A., et al. (1996) · Journal of Microscopy · doi:10.1046/j.1365-2818.1996.66432.x · Cited by 12 · see citing works
The neuro-electronic interface: measurements and model predictions
Grattarola, M., Bove, M., Verreschi, G., Martinoia, S., & Tedesco, M. (1996) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00154550 · Cited by 6 · see citing works
In Vitro Methods for the Assessment of L-Cysteine Conjugate Toxicity
Buckberry, L. D., Adcock, H. J., Adler, J., et al. (1994) · Alternatives to Laboratory Animals · doi:10.1177/026119299402200203 · Cited by 4 · see citing works
Self-citationIn vitro cytotoxicity of silicic acid in comparison with that of selenious acid
Tanaka, T., Tanigawa, T., Nose, T., et al. (1994) · The Journal of Trace Elements in Experimental Medicine · Cited by 4 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454 · see citing works
“While as a material silicon is chemically inert and biocompatible, permitting cell growth and not causing particular adverse reactions in tissue over long implantation periods (Bayliss et al., 1999; Shin et al., 2019), its high stiffness leads to poor tissue compatibility when applied to such an invasive format.”
Background
- Authors
- Bayliss, S. C., Buckberry, L. D., Fletcher, I., & Tobin, M. J.
- Affiliations
- De Montfort University (GB)
- Daresbury Laboratory (GB)
- Corresponding author
- Bayliss, S.C
- Venue
- Sensors and Actuators A Physical
- Publisher
- Elsevier BV
- Published
- 1999-04
- Volume
- 74
- Issue
- 1-3
- Pages
- 139-142
- ISSN
- 0924-4247 (ISSN-L)
- OpenAlex
- W2008301276
- Cited by
- 93
- References
- 23
- Citations by year
- 2025: 2 · 2024: 2 · 2021: 2 · 2020: 1 · 2019: 1 · 2018: 2 · 2017: 2 · 2016: 2 · 2015: 4 · 2014: 4 · 2013: 5 · 2012: 3
- FWCI
- 1.20
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Sensors and Actuators A Physical (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Materials Chemistry › Silicon Nanostructures and Photoluminescence
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Keywords
- neuronal cell culture, porous silicon, polycrystalline silicon, silicon nanostructures, cell adhesion, cell viability, silicon substrate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review