Configurations used in the design of screen-printed enzymatic biosensors. A review
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foulds, N. C., & Lowe, C. R. (1986) · Journal of the Chemical Society, Faraday Transactions 1: Physical Chemistry in Condensed Phases · doi:10.1039/f19868201259 · Cited by 532
Determination of anticholinesterase pesticides in real samples using a disposable biosensor
Palchetti, I., Cagnini, A., Del Carlo, M., Coppi, C., Mascini, M., & Turner, A. P. F. (1997) · Analytica Chimica Acta · doi:10.1016/s0003-2670(96)00418-7 · Cited by 190
Printed amperometric sensor based on TCNQ and cholinesterase
Kulys, J. J., & D'Costa, E. J. (1991) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(91)87034-9 · Cited by 137
Silber, A., Hampp, N., & Schuhmann, W. W. (1996) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(96)88408-9 · Cited by 108
Rippeth, J. J., Gibson, T. D., Hart, J. P., Hartley, I. C., & Nelson, G. (1997) · The Analyst · doi:10.1039/a704291d · Cited by 89
Sprules, S. D., Hart, J. P., Wring, S. A., & Pittson, R. W. (1995) · Analytica Chimica Acta · doi:10.1016/0003-2670(94)00565-4 · Cited by 74
Hajizadeh, K., Halsall, H. B., & Heineman, W. R. (1991) · Talanta · doi:10.1016/0039-9140(91)80007-m · Cited by 62
Simultaneous determination of maltose and glucose using a screen-printed electrode system
Ge, F., Zhang, X., Zhang, Z.-P., & Xiao-Mei, Z. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00122-x · Cited by 50
Wang, J., & Zhang, X. (1999) · Analytical Letters · doi:10.1080/00032719908542929 · Cited by 35
Galán-Vidal, C. A., Muñoz, F. X., Domı́nguez, C., et al. (1998) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(98)00276-7 · Cited by 33
Cited by
Sensor and biosensor preparation, optimisation and applications of Prussian Blue modified electrodes
Ricci, F., & Palleschi, G. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.001 · Cited by 781
Biosensors in clinical chemistry
D'Orazio, P. (2003) · Clinica Chimica Acta · doi:10.1016/s0009-8981(03)00241-9 · Cited by 524
New directions in screen printed electroanalytical sensors: an overview of recent developments
Metters, J. P., Kadara, R. O., & Banks, C. E. (2011) · The Analyst · doi:10.1039/c0an00894j · Cited by 474
The Electrochemistry of Carbon Nanotubes: Fundamentals and Applications
Pumera, M. (2009) · Chemistry – A European Journal · doi:10.1002/chem.200900421 · Cited by 376
Ricci, F., Amine, A., Palleschi, G., & Moscone, D. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00169-0 · Cited by 349
Metadata
- Authors
- Albareda-Sirvent, M., Merkoçi, A., & Alegret, S.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2000-09
- Volume
- 69
- Issue
- 1-2
- Pages
- 153-163
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2021108035
- Cited by
- 325
- References
- 10
- FWCI
- 15.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.