CoChat

Evaluation of the Applied Biosystems automated Taqman polymerase chain reaction system for the detection of meningococcal DNA

Open access
Guiver, M · 2000 · FEMS Immunology and Medical Microbiology
Cited by 142

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

In a period where the proportion of culture confirmed cases in the UK has been steadily declining, diagnosis by PCR has been used to increase the number of confirmed cases and provide additional epidemiological data. This report presents a comparative evaluation of the fluorogenic probe-based 5' exonuclease assay (Taqman) using the Perkin-Elmer Applied Biosystems automated sequence detection system 7700 with previously reported polymerase chain reaction enzyme-linked immunosorbent (PCR ELISA) assays for the detection of meningococcal DNA in CSF, plasma and serum samples. Taqman assays developed were based on the detection of a meningococcal capsular transfer gene (ctrA), the insertion sequence IS1106 and the sialytransferase gene (siaD) for serogroup B and C determination and compared with similar assays in a PCR ELISA format. The Taqman ctrA assay was specific for Neisseria meningitidis, however the IS1106 assay gave false positive reactions with a number of non-meningococcal isolates. Sensitivity of the Taqman ctrA, IS1106 and siaD assays testing samples from culture-confirmed cases were 64, 69 and 50%, respectively, compared with 26, 67 and 43% for the corresponding PCR ELISA assays. Improvements to the DNA extraction procedure has increased the sensitivity to 93 and 91% for the TaqMan ctrA and siaD assays, respectively, compared to culture confirmed cases. Since the introduction of Taqman PCR a 56% increase in laboratory confirmed cases of meningococcal disease has been observed compared to culture only confirmed cases. The developed Taqman assays for the diagnosis of meningococcal disease enables a high throughput, rapid turnaround of samples with considerable reduced risk of contamination.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0928-8244(00)00152-8

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 142

Metadata

Authors
Guiver, M.
Venue
FEMS Immunology and Medical Microbiology
Publisher
Wiley
Published
2000-06
Volume
28
Issue
2
Pages
173-179
ISSN
0928-8244 (ISSN-L)
OpenAlex
W2146211405
Cited by
142
References
1
FWCI
11.46
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of the Applied Biosystems automated Taqman polymerase chain reaction system for the detection of meningococcal DNA. https://app.cochat.ai/papers/10.1016/s0928-8244(00)00152-8
The paper
Guiver, M. (2000). Evaluation of the Applied Biosystems automated Taqman polymerase chain reaction system for the detection of meningococcal DNA. FEMS Immunology and Medical Microbiology. https://doi.org/10.1016/s0928-8244(00)00152-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.