Cited by 4Polymer Surface Interaction StudiesBlood transfusion and managementMechanical Circulatory Support Devices

Biocompatibility in transfusion medicine

NYDEGGER, U·1996·Transfusion Science

Abstract

The first measurable event upon interaction of artificial surfaces with blood is adsorption of proteins within seconds or minutes. At a later stage, blood cells interact with the surfaces through the initially deposited protein layer. The chemical composition of the surface is only one criterion for differential deposition of various plasma proteins, with molecular motion (polymer chain ends, loops and their flexibility), and topography (roughness, porosity) of the surface decisively influencing the interactions as well. Initially incompatible surfaces, which may be dangerous to the patient, may be rendered compatible by physicochemical surface modifications. Modern methods to estimate biocompatibility have become so sensitive that they may detect biological modifications of the blood after contact with a surface, which has no consequence for the patient. In these cases it is often difficult to decide whether a material should be classified as biocompatible or non-biocompatible. This paper discusses some methods that we have used for the study of biocompatibility of extracorporeal circuitry. It seems to us that minute signs of laboratory evidence for bioincompatibility should not preclude usage of the material in a clinical setting.

Integrity signals

Registry

Crossref · 10.1016/s0955-3886(96)90081-8

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Super-hydrophobic polymer surfaces with water contact angles above 150°, low surface energy, and self-cleaning properties resist microbial cell adhesion in short-term applications.

    “Super-hydrophobic polymer surfaces, such as very smooth silicone, polyurethane, polytetrafluoroethylene (PTFE), poly(vinyl chloride) (PVC), and polyethylene (PE), that have water contact angles larger than 150°, low surface energy,55,56 as well as unique water repellent57 and self-cleaning abilities,56 are known to have resistance to microbial cell adhesion during short-term applications.58”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
NYDEGGER, U.
Affiliations
Swiss Red Cross (CH)
Corresponding author
NYDEGGER, U
Venue
Transfusion Science
Publisher
Elsevier BV
Published
1996-12
Volume
17
Issue
4
Pages
481-488
ISSN
0955-3886 (ISSN-L)
OpenAlex
W1975010661
Cited by
4
References
14
Citations by year
2016: 1 · 2014: 1 · 2013: 1
FWCI
0.00
Type
journal article
Language
en
Open access
closed
Locations
  • Transfusion Science (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
  • Health Sciences › Medicine › Biochemistry › Blood transfusion and management
  • Physical Sciences › Engineering › Biomedical Engineering › Mechanical Circulatory Support Devices
Keywords
biocompatibility, hemocompatibility, protein adsorption, plasma proteins, surface topography, surface roughness, surface modification, transfusion medicine
MeSH terms
Biocompatible Materials, Blood Transfusion, Humans

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review