Biocompatibility in transfusion medicine
Abstract
The first measurable event upon interaction of artificial surfaces with blood is adsorption of proteins within seconds or minutes. At a later stage, blood cells interact with the surfaces through the initially deposited protein layer. The chemical composition of the surface is only one criterion for differential deposition of various plasma proteins, with molecular motion (polymer chain ends, loops and their flexibility), and topography (roughness, porosity) of the surface decisively influencing the interactions as well. Initially incompatible surfaces, which may be dangerous to the patient, may be rendered compatible by physicochemical surface modifications. Modern methods to estimate biocompatibility have become so sensitive that they may detect biological modifications of the blood after contact with a surface, which has no consequence for the patient. In these cases it is often difficult to decide whether a material should be classified as biocompatible or non-biocompatible. This paper discusses some methods that we have used for the study of biocompatibility of extracorporeal circuitry. It seems to us that minute signs of laboratory evidence for bioincompatibility should not preclude usage of the material in a clinical setting.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Super-hydrophobic polymer surfaces with water contact angles above 150°, low surface energy, and self-cleaning properties resist microbial cell adhesion in short-term applications.
“Super-hydrophobic polymer surfaces, such as very smooth silicone, polyurethane, polytetrafluoroethylene (PTFE), poly(vinyl chloride) (PVC), and polyethylene (PE), that have water contact angles larger than 150°, low surface energy,55,56 as well as unique water repellent57 and self-cleaning abilities,56 are known to have resistance to microbial cell adhesion during short-term applications.58”
From Recent advances in thromboresistant and antimicrobial polymers for biomedical applications: just say yes to nitric oxide (NO) (2016) · cites this paper as [58]
Cites
Self-Condensing Vinyl Polymerization: An Approach to Dendritic Materials
Fréchet, J. M. J., Henmi, M., Gitsov, I., et al. (1995) · Science · doi:10.1126/science.269.5227.1080 · Cited by 851 · see citing works
Fabrication of hollow porous shells of calcium carbonate from self-organizing media
Walsh, D., & Mann, S. (1995) · Nature · doi:10.1038/377320a0 · Cited by 418 · see citing works
Hemostasis Changes During Cardiopulmonary Bypass Surgery
Mammen, E. F., Koets, M., Washington, B., et al. (1985) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-2007-1004382 · Cited by 341 · see citing works
Моrawitz, P. (1905) · Reviews of physiology, biochemistry and pharmacology · doi:10.1007/bf02321003 · Cited by 230 · see citing works
Holloway, D. S., Summaria, L., Sandesara, J., et al. (1988) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1646770 · Cited by 228 · see citing works
(1903) · Nature · doi:10.1038/068547a0 · Cited by 197 · see citing works
Foreign Body Infection: Role of Fibronectin as a Ligand for the Adherence of Staphylococcus aureus
Vaudaux, P. E., Suzuki, R., Waldvogel, F. A., et al. (1984) · The Journal of Infectious Diseases · doi:10.1093/infdis/150.4.546 · Cited by 156 · see citing works
Biocompatibility of different hemodialysis membranes: activation of complement and leukopenia.
Wegmüller, E., Montandon, A., Nydegger, U., et al. (1986) · PubMed · Cited by 46 · see citing works
Self-citationJahns‐Streubel, G., Haeffner‐Cavaillon, N., Nydegger, U. E., et al. (1993) · Clinical Materials · doi:10.1016/0267-6605(93)90017-2 · Cited by 41 · see citing works
Self-citationIN VITRO EVALUATION OF THE EFFICACY AND BIOCOMPATIBILITY OF NEW, SYNTHETIC ABO IMMUNOABSORBENTS
Rieben, R., Korchagina, E., ALLMEN, E. V., et al. (1995) · Transplantation · doi:10.1097/00007890-199509000-00004 · Cited by 38 · see citing works
FPA Content ‐ a Criterion of Quality for Plasma as Factor VIII Source
Pflugshaupt, R., & Kurt, G. (1983) · Vox Sanguinis · doi:10.1111/j.1423-0410.1983.tb01908.x · Cited by 36 · see citing works
Chemical Modification of Cellulosic Membranes and Their Blood Compatibility
Paul, D., Malsch, G., Bossin, E., et al. (1990) · Artificial Organs · doi:10.1111/j.1525-1594.1990.tb01606.x · Cited by 27 · see citing works
Hemofiltration during Cardiopulmonary Bypass: Quality Assessment of Hemoconcentrated Blood
Walpoth, B., Amport, T., Schmid, R. A., et al. (1994) · The Thoracic and Cardiovascular Surgeon · doi:10.1055/s-2007-1016480 · Cited by 14 · see citing works
Donor Safety and Plasma Quality in Automated Plasmapheresis
Aeschbache, B., Haeberli, A., & Nydegger, U. E. (1989) · Vox Sanguinis · doi:10.1111/j.1423-0410.1989.tb01145.x · Cited by 12 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Wo, Y., Brisbois, E. J., Bartlett, R. H., & Meyerhoff, M. E. (2016) · Biomaterials Science · doi:10.1039/c6bm00271d · Cited by 251 · see citing works
- Authors
- NYDEGGER, U.
- Affiliations
- Swiss Red Cross (CH)
- Corresponding author
- NYDEGGER, U
- ORCID
- NYDEGGER, U
- Venue
- Transfusion Science
- Publisher
- Elsevier BV
- Published
- 1996-12
- Volume
- 17
- Issue
- 4
- Pages
- 481-488
- ISSN
- 0955-3886 (ISSN-L)
- OpenAlex
- W1975010661
- Cited by
- 4
- References
- 14
- Citations by year
- 2016: 1 · 2014: 1 · 2013: 1
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Transfusion Science (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Health Sciences › Medicine › Biochemistry › Blood transfusion and management
- Physical Sciences › Engineering › Biomedical Engineering › Mechanical Circulatory Support Devices
- Keywords
- biocompatibility, hemocompatibility, protein adsorption, plasma proteins, surface topography, surface roughness, surface modification, transfusion medicine
- MeSH terms
- Biocompatible Materials, Blood Transfusion, Humans
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review