A new amperometric glucose microsensor: in vitro and short-term in vivo evaluation
Abstract
For biosensor fabrication, it is important to optimize materials and methods in order to create predictable function in vitro and in vivo. For this reason, we designed a new glucose sensor ('revised protocol') that utilized an outer permselective membrane made of amphiphobic polyurethane which allows glucose passage through hydrophilic segments. An inner polyethersulfone membrane, stabilized with a trimethoxysilane, provided specificity. Before application of the inner membrane, it was necessary to etch the platinum electrode with a radio frequency oxygen plasma. The revised protocol sensors (n=185) were compared with sensors fabricated with an earlier ('original') protocol (n=204) which used an outer polyurethane without hydrophilic segments and a complex inner membrane of cellulose acetate and Nafion. The function of revised protocol sensors was more predictable in vitro as evidenced by a much lower variation of glucose sensitivity than the original protocol sensors. Revised and original protocol sensors were nearly linear up to a glucose concentration of 20 mM. In vitro interference from 0.1 mM acetaminophen was minimal in both groups of sensors and would be expected to represent about 2% of the total sensor response at normal glucose levels for revised protocol sensors. Prolonged testing of the revised protocol sensors for 11 days during immersion in buffer revealed stable sensitivities (day 1: 6.12+/-1.34 nA/mM; day 3: 6.33+/-1.40; day 8: 7.13+/-1.39; and day 11: 7.56+/-1.47; sensitivity for day 1 vs. each other day: not significant) and no critical loss of glucose oxidase activity. The response of the revised protocol sensors (n=7) to intraperitoneal glucose was tested in rats approximately one day after subcutaneous implantation and the sensors tracked glucose closely with a slight lag of 3-6 min.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Tecoflex SG-85A polyurethane membranes on needle-type glucose sensors in rats after 30 h provided the biocompatibility often seen with polyurethane and ensured ideal sensor performance by limiting glucose diffusion.
“The Tecoflex SG-85A membrane provided the biocompatibility often observed with polyurethane while also ensuring ideal sensor performance by limiting glucose diffusion.34”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [137]
The sensors accurately tracked glucose with relatively short lag times of about 4.5 min.
“The sensors were found to accurately track the glucose with relatively short lag times (~4.5 min).”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [137]
The citation lists haven’t been fetched yet
References 37 · Cited by 81
- Authors
- Ward, W. K., Jansen, L. B., Anderson, E., Reach, G., Klein, J.-C., & Wilson, G. S.
- Affiliations
- iSense (United States) (US)
- Centre de Morphologie Mathématique - CMM (FR)
- University of Kansas (US)
- Corresponding author
- Ward, W.Kenneth
- ORCID
- Wilson, George S
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2002-03
- Volume
- 17
- Issue
- 3
- Pages
- 181-189
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W1987199136
- Cited by
- 81
- References
- 37
- Citations by year
- 2025: 1 · 2023: 3 · 2021: 2 · 2020: 2 · 2019: 4 · 2017: 2 · 2016: 6 · 2015: 4 · 2014: 1 · 2013: 6 · 2012: 5
- FWCI
- 5.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Biosensors and Bioelectronics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01dk055297-03)
- Centers for Disease Control and Prevention (R08/CCR017796-01)
- National Institute of Diabetes and Digestive and Kidney Diseases (R01 DK55297)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Keywords
- amperometric glucose sensor, permselective membranes, polyethersulfone membranes, trimethoxysilane, platinum electrode, oxygen plasma etching, glucose oxidase, acetaminophen interference, sensor stability, subcutaneous implantation, in vivo glucose monitoring
- MeSH terms
- Animals, Blood Glucose, Electrochemistry, Glucose, Reproducibility of Results, Biosensing Techniques, Rats, Sprague-Dawley, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review