Lung cancer identification by the analysis of breath by means of an array of non-selective gas sensors
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of discrimination mechanisms in the mammalian olfactory system using a model nose
Persaud, K., & Dodd, G. (1982) · Nature · doi:10.1038/299352a0 · Cited by 1,592
Massart, D. L. (1988) · Cited by 1,347
Quantitative Analysis of Urine Vapor and Breath by Gas-Liquid Partition Chromatography
Pauling, L., Robinson, A. B., Teranishi, R., & Cary, P. (1971) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.68.10.2374 · Cited by 1,025
Volatile organic compounds in breath as markers of lung cancer: a cross-sectional study
Phillips, M., Gleeson, K., Hughes, J. M. B., Greenberg, J., Cataneo, R. N., Baker, L., & McVay, W. P. (1999) · The Lancet · doi:10.1016/s0140-6736(98)07552-7 · Cited by 918
Biochemical Profile of Uremic Breath
Simenhoff, M. L., Burke, J. F., Saukkonen, J. J., Ordinario, A. T., Doty, R., & Dunn, S. (1977) · New England Journal of Medicine · doi:10.1056/nejm197707212970303 · Cited by 246
Electronic noses: a review of signal processing techniques
Hines, E. L., Llobet, E., & Gardner, J. W. (1999) · IEE Proceedings - Circuits Devices and Systems · doi:10.1049/ip-cds:19990670 · Cited by 210
O'Neill, H. J., Gordon, S. M., O'Neill, M. H., Gibbons, R. D., & Szidon, J. P. (1988) · Clinical Chemistry · doi:10.1093/clinchem/34.8.1613 · Cited by 207
A novel method for diabetes diagnosis based on electronic nose
Wang, P., Yi, T., Haibao, X., & Farong, S. (1997) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00059-6 · Cited by 146
Brunink, J. A. J., Natale, C. D., Bungaro, F., Davide, F., D’Amico, A., Paolesse, R., Boschi, T., Faccio, M., & Ferri, G. (1996) · Analytica Chimica Acta · doi:10.1016/0003-2670(96)00017-7 · Cited by 139
Self-citationGas analysis by partial model building
Horner, G., & Hierold, C. (1990) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(90)85002-g · Cited by 95
Human skin odor analysis by means of an electronic nose
Natale, C. D., Macagnano, A., Paolesse, R., Tarizzo, E., Mantini, A., & D’Amico, A. (2000) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00313-5 · Cited by 74
Self-citation
Cited by
Electronic Nose: Current Status and Future Trends
Röck, F., Barsan, N., & Weimar, U. (2008) · Chemical Reviews · doi:10.1021/cr068121q · Cited by 1,437
Diagnosing lung cancer in exhaled breath using gold nanoparticles
Peng, G., Tisch, U., Adams, O., Hakim, M., Shehada, N., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., & Haick, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.235 · Cited by 1,263
Applications and Advances in Electronic-Nose Technologies
Wilson, A. D., & Baietto, M. (2009) · Sensors · doi:10.3390/s90705099 · Cited by 1,144
Diagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
Porphyrinoids for Chemical Sensor Applications
Paolesse, R., Nardis, S., Monti, D., Stefanelli, M., & Di Natale, C. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00361 · Cited by 874
Self-citation
Metadata
- Authors
- Di Natale, C., Macagnano, A., Martinelli, E., Paolesse, R., D'Arcangelo, G., Roscioni, C., Finazzi-Agrò, A., & D'Amico, A.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2003-09
- Volume
- 18
- Issue
- 10
- Pages
- 1209-1218
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W1992747532
- Cited by
- 663
- References
- 11
- FWCI
- 14.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.