Combining nucleic acid amplification and detection
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Beacons: Probes that Fluoresce upon Hybridization
Tyagi, S., & Kramer, F. R. (1996) · Nature Biotechnology · doi:10.1038/nbt0396-303 · Cited by 4,155
Holland, P. M., Abramson, R. D., Watson, R., & Gelfand, D. H. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.16.7276 · Cited by 2,693
Scanometric DNA Array Detection with Nanoparticle Probes
Taton, T. A., Mirkin, C. A., & Letsinger, R. L. (2000) · Science · doi:10.1126/science.289.5485.1757 · Cited by 2,411
Mutation detection and single-molecule counting using isothermal rolling-circle amplification
Lizardi, P. M., Huang, X., Zhu, Z., Bray-Ward, P., Thomas, D. C., & Ward, D. C. (1998) · Nature Genetics · doi:10.1038/898 · Cited by 1,442
Nucleic acid sequence-based amplification
Compton, J. (1991) · Nature · doi:10.1038/350091a0 · Cited by 1,344
Genetic disease detection and DNA amplification using cloned thermostable ligase.
Barany, F. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.1.189 · Cited by 796
Detection of PCR products using self-probing amplicons and fluorescence
Whitcombe, D., Theaker, J., Guy, S. P., Brown, T., & Little, S. (1999) · Nature Biotechnology · doi:10.1038/11751 · Cited by 697
Schweitzer, B., Wiltshire, S., Lambert, J., O'Malley, S., Kukanskis, K., Zhu, Z., Kingsmore, S. F., Lizardi, P. M., & Ward, D. C. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.170237197 · Cited by 597
Self-citationLyamichev, V. I., Mast, A. L., Hall, J. G., Prudent, J. R., Kaiser, M. W., Takova, T., Kwiatkowski, R. W., Sander, T. J., de Arruda, M., Arco, D. A., et al. (1999) · Nature Biotechnology · doi:10.1038/7044 · Cited by 519
A closed tube format for amplification and detection of DNA based on energy transfer
Nazarenko, I. A., Bhatnagar, S. K., & Hohman, R. J. (1997) · Nucleic Acids Research · doi:10.1093/nar/25.12.2516 · Cited by 350
Universal DNA microarray method for multiplex detection of low abundance point mutations
Gerry, N. P., Witowski, N. E., Day, J., Hammer, R. P., Barany, G., & Barany, F. (1999) · Journal of Molecular Biology · doi:10.1006/jmbi.1999.3063 · Cited by 346
Mode of action and application of Scorpion primers to mutation detection
Thelwell, N. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.19.3752 · Cited by 337
Sensitive detection of DNA polymorphisms by the serial invasive signal amplification reaction
Hall, J. G., Eis, P. S., Law, S. M., Reynaldo, L. P., Prudent, J. R., Marshall, D. J., Allawi, H. T., Mast, A. L., Dahlberg, J. E., Kwiatkowski, R. W., et al. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.140225597 · Cited by 239
Piatek, A. S., Telenti, A., Murray, M. R., El-Hajj, H., Jacobs, W. R., Kramer, F. R., & Alland, D. (2000) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.44.1.103-110.2000 · Cited by 218
Universal DNA array detection of small insertions and deletions in BRCA1 and BRCA2
Favis, R., Day, J. P., Gerry, N. P., Phelan, C., Narod, S., & Barany, F. (2000) · Nature Biotechnology · doi:10.1038/75452 · Cited by 206
Loeb, K. R., Jerome, K. R., Goddard, J., Huang, M.-L., Cent, A., & Corey, L. (2000) · Hepatology · doi:10.1053/jhep.2000.9878 · Cited by 161
Emery, S., Bodrug, S., Richardson, B. A., Giachetti, C., Bott, M. A., Panteleeff, D., Jagodzinski, L. L., Michael, N. L., Nduati, R. W., Bwayo, J. J., et al. (2000) · Journal of Clinical Microbiology · doi:10.1128/jcm.38.7.2688-2695.2000 · Cited by 146
Wiltshire, S., O’Malley, S., Lambert, J., Kukanskis, K., Edgar, D., Kingsmore, S. F., & Schweitzer, B. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.12.1990 · Cited by 145
Self-citationAnchored multiplex amplification on a microelectronic chip array
Westin, L., Xu, X., Miller, C., Wang, L., Edman, C. F., & Nerenberg, M. I. (2000) · Nature Biotechnology · doi:10.1038/72658 · Cited by 116
Yu, M., Chuang, W., Dai, C., Chen, S., Lin, Z., Hsieh, M., Wang, L., & Chang, W. (2000) · Journal of Clinical Microbiology · doi:10.1128/jcm.38.8.2933-2939.2000 · Cited by 34
Pawlowski, V., Révillion-Carette, F., Hornez, L., & Jp, P. (2000) · PubMed · Cited by 33
Jordens, J. Z., Lanham, S., Pickett, M. A., Amarasekara, S., Abeywickrema, I., & Watt, P. J. (2000) · Journal of Virological Methods · doi:10.1016/s0166-0934(00)00195-6 · Cited by 31
Diagnosis of Human Papillomavirus Gynecologic Infections
Wick, M. J. (2000) · Clinics in Laboratory Medicine · doi:10.1016/s0272-2712(18)30062-3 · Cited by 5
Cited by
Quantification of mRNA using real-time reverse transcription PCR (RT-PCR): trends and problems
Bustin, S. (2002) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0290023 · Cited by 2,546
Applications of Aptamers as Sensors
Cho, E. J., Lee, J.-W., & Ellington, A. D. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112851 · Cited by 788
Bio-Bar-Code-Based DNA Detection with PCR-like Sensitivity
Nam, J.-M., Stoeva, S. I., & Mirkin, C. A. (2004) · Journal of the American Chemical Society · doi:10.1021/ja049384+ · Cited by 744
Wang, F., Lu, C.-H., & Willner, I. (2014) · Chemical Reviews · doi:10.1021/cr400354z · Cited by 649
Next-Generation in Situ Hybridization Chain Reaction: Higher Gain, Lower Cost, Greater Durability
Choi, H. M. T., Beck, V. A., & Pierce, N. A. (2014) · ACS Nano · doi:10.1021/nn405717p · Cited by 629
Metadata
- Authors
- Schweitzer, B., & Kingsmore, S.
- Venue
- Current Opinion in Biotechnology
- Publisher
- Elsevier BV
- Published
- 2001-02
- Volume
- 12
- Issue
- 1
- Pages
- 21-27
- ISSN
- 0958-1669 (ISSN-L)
- OpenAlex
- W2047236144
- Cited by
- 193
- References
- 23
- FWCI
- 0.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.