Tissue Engineered Skeletal Muscle: Preparation of Highly Dense, Highly Oriented Hybrid Muscular Tissues
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We prepared highly dense, highly oriented hybrid muscular tissues that are composed of C2C12 cells (skeletal muscle myoblast cell line) and type I collagen. A cold mixture of C2C12 cells suspended in DMEM and type I collagen solution was poured into capillary tube molds of two different sizes (inner diameters; 0.90 and 0.53 mm, respectively). One end of each mold was sealed. Upon centrifugation (1000 rpm, 5 min) and subsequent thermal gelation, a rod-shaped gel was obtained. It was cultured in an agarose gel-coated dish for 7 days (first for 3 days in a growth medium and then for 4 days in a differentiation medium), during which time it shrank to become a highly dense tissue. Small-diameter rod-shaped, highly dense cellular assemblages with multinucleated myotubes were formed and only few necrotic cells at the core of the tissue were observed. On the other hand, a ring-shaped tissue prepared using a specially devised agarose gel mold was subjected to cyclic stretching at 60 rpm, resulting in the formation of a highly dense, highly oriented hybrid muscular tissue in which both densely accumulated cells and collagen fiber bundles tended to be aligned in the direction of stretching. The hybrid muscular tissues that were prepared using via sequential procedures of a centrifugal cell packing method and a mechanical stress-loading method became closer to native muscular tissues in terms of cell density and orientation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SATELLITE CELL OF SKELETAL MUSCLE FIBERS
Mauro, A. (1961) · The Journal of Cell Biology · doi:10.1083/jcb.9.2.493 · Cited by 3,683
Cited by
Hydrogels for tissue engineering: scaffold design variables and applications
Drury, J. L., & Mooney, D. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00340-5 · Cited by 5,136
The tensile properties of alginate hydrogels
Drury, J. L., Dennis, R. G., & Mooney, D. J. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.002 · Cited by 573
Qazi, T. H., Mooney, D. J., Pumberger, M., Geißler, S., & Duda, G. N. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.110 · Cited by 433
Scaffolding Biomaterials for 3D Cultivated Meat: Prospects and Challenges
Bomkamp, C., Skaalure, S. C., Fernando, G. F., Ben‐Arye, T., Swartz, E. W., & Specht, E. A. (2022) · Advanced Science · doi:10.1002/advs.202102908 · Cited by 349
Rapid formation of functional muscle in vitro using fibrin gels
Huang, Y.-C., Dennis, R. G., Larkin, L., & Baar, K. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00273.2004 · Cited by 316
Metadata
- Authors
- Okano, T.
- Venue
- Cell Transplantation
- Publisher
- Elsevier BV
- Published
- 1998-01-02
- Volume
- 7
- Issue
- 1
- Pages
- 71-82
- ISSN
- 0963-6897 (ISSN-L)
- OpenAlex
- W2042015800
- Cited by
- 127
- References
- 1
- FWCI
- 4.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tissue Engineered Skeletal Muscle: Preparation of Highly Dense, Highly Oriented Hybrid Muscular Tissues. https://app.cochat.ai/papers/10.1016/s0963-6897(97)00067-5
- The paper
- Okano, T. (1998). Tissue Engineered Skeletal Muscle: Preparation of Highly Dense, Highly Oriented Hybrid Muscular Tissues. Cell Transplantation. https://doi.org/10.1016/s0963-6897(97)00067-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.