Fibrin gel – advantages of a new scaffold in cardiovascular tissue engineering
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The field of tissue engineering deals with the creation of tissue structures based on patient cells. The scaffold plays a central role in the creation of 3-D structures in cardiovascular tissue engineering like small vessels or heart valve prosthesis. An ideal scaffold should have tissue-like mechanical properties and a complete immunologic integrity. As an alternative scaffold the use of fibrin gel was investigated. METHODS: Preliminary, the degradation of the fibrin gel was controlled by the supplementation of aprotinin to the culture medium. To prevent tissue from shrinking a mechanical fixation of the gel with 3-D microstructure culture plates and a chemical fixation with poly-L-lysine in different fixation techniques were studied. The thickness of the gel layer was changed from 1 to 3 mm. The tissue development was analysed by light, transmission and scanning electron microscopy. Collagen production was detected by the measurement of hydroxyproline. Injection molding techniques were designed for the formation of complex 3-D tissue structures. RESULTS: The best tissue development was observed at an aprotinin concentration of 20 microg per cc culture medium. The chemical border fixation of the gel by poly-L-lysine showed the best tissue development. Up to a thickness of 3 mm no nutrition problems were observed in the light and transmission electron microscopy. The molding of a simplified valve conduit was possible by the newly developed molding technique. CONCLUSION: Fibrin gel combines a number of important properties of an ideal scaffold. It can be produced as a complete autologous scaffold. It is moldable and degradation is controllable by the use of aprotinin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A simplified method for the analysis of hydroxyproline in biological tissues
Kesava Reddy, G., & Enwemeka, C. S. (1996) · Clinical Biochemistry · doi:10.1016/0009-9120(96)00003-6 · Cited by 1,296
Biodegradable Polymer Scaffolds for Tissue Engineering
Freed, L. E., Vunjak-Novakovic, G., Biron, R. J., Eagles, D. B., Lesnoy, D. C., Barlow, S. K., & Langer, R. (1994) · Nature Biotechnology · doi:10.1038/nbt0794-689 · Cited by 1,235
Biomaterials in Tissue Engineering
Hubbell, J. A. (1995) · Nature Biotechnology · doi:10.1038/nbt0695-565 · Cited by 1,060
Dynamic Cell Seeding of Polymer Scaffolds for Cartilage Tissue Engineering
Vunjak‐Novakovic, G., Obradovic, B., Martin, I., Bursac, P. M., Langer, R., & Freed, L. E. (1998) · Biotechnology Progress · doi:10.1021/bp970120j · Cited by 551
Hubbell, J. A. (1999) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(99)80021-4 · Cited by 473
Creation Of Viable Pulmonary Artery Autografts Through Tissue Engineering
Shinoka, T., Shum-Tim, D., Ma, P. X., Tanel, R. E., Isogai, N., Langer, R., Vacanti, J. P., & Mayer, J. E. (1998) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(98)70315-0 · Cited by 444
Evaluation of matrix scaffolds for tissue engineering of articular cartilage grafts
Grande, D. A., Halberstadt, C., Naughton, G., Schwartz, R., & Manji, R. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199702)34:2<211::aid-jbm10>3.0.co;2-l · Cited by 439
Fibrin gel as a three dimensional matrix in cardiovascular tissue engineering
Ye, Q., Zünd, G., Benedikt, P., Jockenhoevel, S., Hoerstrup, S. P., Sakyama, S., Hubbell, J. A., & Turina, M. (2000) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(00)00373-0 · Cited by 419
Self-citationChevallay, B., & Herbage, D. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344779 · Cited by 403
Hata, R., & Senoo, H. (1989) · Journal of Cellular Physiology · doi:10.1002/jcp.1041380103 · Cited by 384
Bader, A., Schilling, T., Teebken, O. E., Brandes, G., Herden, T., Steinhoff, G., & Haverich, A. (1998) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(98)00171-7 · Cited by 340
Cross-Linking Exogenous Bifunctional Peptides into Fibrin Gels with Factor XIIIa
Schense, J. C., & Hubbell, J. A. (1999) · Bioconjugate Chemistry · doi:10.1021/bc9800769 · Cited by 308
Kim, B.-S., Putnam, A. J., Kulik, T. J., & Mooney, D. J. (1998) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19980105)57:1<46::aid-bit6>3.0.co;2-v · Cited by 272
Effects of mixing on the composition and morphology of tissue‐engineered cartilage
Vunjak‐Novakovic, G., Freed, L. E., Biron, R. J., & Langer, R. (1996) · AIChE Journal · doi:10.1002/aic.690420323 · Cited by 247
Sittinger, M., Bujia, J., Rotter, N., Reitzel, D., Minuth, W. W., & Burmester, G. R. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85561-x · Cited by 214
Sodian, R., Sperling, J. S., Martin, D. P., Egozy, A., Stock, U., Mayer, J. E., & Vacanti, J. P. (2000) · Tissue Engineering · doi:10.1089/107632700320793 · Cited by 201
The in vitro construction of a tissue engineered bioprosthetic heart valve
Zünd, G. (1997) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(96)01005-6 · Cited by 134
Ye, Q., Zünd, G., Jockenhoevel, S., Schoeberlein, A., Hoerstrup, S. P., Grünenfelder, J., Benedikt, P., & Turina, M. I. (2000) · ASAIO Journal · doi:10.1097/00002480-200011000-00014 · Cited by 53
Self-citation
Cited by
Bone tissue engineering using polycaprolactone scaffolds fabricated via selective laser sintering
Williams, J. M., Adewunmi, A., Schek, R. M., Flanagan, C. L., Krebsbach, P. H., Feinberg, S. E., Hollister, S. J., & Das, S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.11.057 · Cited by 1,563
Department of Materials, U. O. O., Sachlos, E., & Czernuszka, J. (2003) · European Cells and Materials · doi:10.22203/ecm.v005a03 · Cited by 1,303
Bacakova, L., Filova, E., Parizek, M., Ruml, T., & Svorcik, V. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.004 · Cited by 1,000
Fibrin: A versatile scaffold for tissue engineering applications
Ahmed, T. A. E., Dare, E. V., & Hincke, M. (2008) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2007.0435 · Cited by 994
“46 And finally protease inhibitors that are specific for plasmin and matrix metalloproteinases are often added to the in vitro culturing media, 2,25 or alternatively, the plasmin inhibitor, aprotinin, can be immobilized into the fibrin hydrogel.”
InfluentialFibrin gels and their clinical and bioengineering applications
Janmey, P. A., Winer, J. P., & Weisel, J. W. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0327 · Cited by 680
Metadata
- Authors
- Jockenhoevel, S., Zund, G., Hoerstrup, S. P., Chalabi, K., Sachweh, J. S., Demircan, L., Messmer, B. J., & Turina, M.
- Venue
- European Journal of Cardio-Thoracic Surgery
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-04
- Volume
- 19
- Issue
- 4
- Pages
- 424-430
- ISSN
- 1010-7940 (ISSN-L)
- 1873-734X
- OpenAlex
- W2135487197
- Cited by
- 362
- References
- 18
- FWCI
- 6.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.