The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Early experience with robotic technology for thoracoscopic surgery
Abstract
OBJECTIVE: Recently, robots have been introduced into surgical procedures in an attempt to facilitate surgical performance. The purpose of this study was to develop a technique to perform thoracoscopic lung resection using a telemanipulation system. METHODS: We have used a robotic system to perform thoracoscopic surgery in 12 cases: five lobectomies, three tumor enucleations, three excisions and one bulla stitching completed with fibrin glue for spontaneous pneumothorax. The operations were performed using the Intuitive Microsurgical system (Da Vinci System) through three ports and, a fourth space 'service entrance' incision, in the major lung resection. RESULTS: Three procedures begun with the robotic technique were completed by a minimal thoracotomy. No technical operative mishaps were associated with the manoeuvres of robotic arms. In all manoeuvres (up, down, insertion, extraction, etc.), the robotic arms moved appropriately in the favorable operative fields. All patients tolerated the procedure well and the post-operative course was satisfactory, requiring few analgesics. CONCLUSIONS: Although further studies on robotically assisted procedures are needed to clarify the clinical feasibility of this procedure, the results in our cases are encouraging. We believe that thoracoscopic procedures using a robotic manipulation system may be technically feasible in selected cases and in the hands of experienced thoracic surgeons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
First report of the port access international registry
Galloway, A. C., Shemin, R. J., Glower, D. D., Boyer, J. H., Groh, M. A., Kuntz, R. E., Burdon, T. A., Ribakove, G. H., Reitz, B. A., & Colvin, S. B. (1999) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(98)01265-x · Cited by 142
Computer-assisted telemanipulation: an enabling technology for endoscopic coronary artery bypass
Shennib, H., Bastawisy, A., Mack, M. J., & Moll, F. H. (1998) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(98)00659-6 · Cited by 82
Cited by
First experiences with the da Vinci™ operating robot in thoracic surgery☆
Bodner, J., Wykypiel, H., Wetscher, G., & Schmid, T. (2004) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2004.02.001 · Cited by 319
AI in healthcare: A narrative review
Väänänen, A., Haataja, K., Vehviläinen-Julkunen, K., & Toivanen, P. (2021) · F1000Research · doi:10.12688/f1000research.26997.2 · Cited by 69
Metadata
- Authors
- Melfi, F.
- Venue
- European Journal of Cardio-Thoracic Surgery
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-05
- Volume
- 21
- Issue
- 5
- Pages
- 864-868
- ISSN
- 1010-7940 (ISSN-L)
- OpenAlex
- W2129842192
- Cited by
- 383
- References
- 2
- FWCI
- 5.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Early experience with robotic technology for thoracoscopic surgery. https://app.cochat.ai/papers/10.1016/s1010-7940(02)00102-1
- The paper
- Melfi, F. (2002). Early experience with robotic technology for thoracoscopic surgery. European Journal of Cardio-Thoracic Surgery. https://doi.org/10.1016/s1010-7940(02)00102-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.