Mass selective axial ion ejection from a linear quadrupole ion trap
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The electric fields responsible for mass-selective axial ejection (MSAE) of ions trapped in a linear quadrupole ion trap have been studied using a combination of analytic theory and computer modeling. Axial ejection occurs as a consequence of the trapped ions' radial motion, which is characterized by extrema that are phase-synchronous with the local RF potential. As a result, the net axial electric field experienced by ions in the fringe region, over one RF cycle, is positive. This axial field depends strongly on both the axial and radial ion coordinates. The superposition of a repulsive potential applied to an exit lens with the diminishing quadrupole potential in the fringing region near the end of a quadrupole rod array can give rise to an approximately conical surface on which the net axial force experienced by an ion, averaged over one RF cycle, is zero. This conical surface has been named the cone of reflection because it divides the regions of ion reflection and ion ejection. Once an ion penetrates this surface, it feels a strong net positive axial force and is accelerated toward the exit lens. As a consequence of the strong dependence of the axial field on radial displacement, trapped thermalized ions can be ejected axially from a linear ion trap in a mass-selective way when their radial amplitude is increased through a resonant response to an auxiliary signal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A two-dimensional quadrupole ion trap mass spectrometer
Schwartz, J. C., Senko, M. W., & Syka, J. E. P. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00384-7 · Cited by 796 · cited 7×
“In general, the radial excitation voltage is lower than that used to perform mass-selective radial ejection [3] since the goal is provide a degree of radial excitation rather than radial ejection.”
BackgroundMethodInfluentialRadiofrequency Spectroscopy of Stored Ions I: Storage
Dehmelt, H. G. (1968) · Advances in Atomic and Molecular Physics · doi:10.1016/s0065-2199(08)60170-0 · Cited by 765 · cited 10×
“The analytic results relied upon the Dehmelt approximation, embodied in Eq 20 to obtain Ez,quad RF.”
BackgroundInfluentialQuadrupole Mass Spectrometry and its Applications
(1976) · Elsevier eBooks · doi:10.1016/c2013-0-04436-2 · Cited by 700 · cited 1×
“These fringing fields, positioned at both ends of the quadrupole, are most often deleterious to RF/DC quadrupole performance [5] as well as radial ejection from a linear ion trap [3].”
BackgroundA new linear ion trap mass spectrometer
Hager, J. W. (2002) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.607 · Cited by 479 · cited 7×
“4 V auxiliary amplitude with 4 V on the exit lens, the efficiency predicted by simulations for these conditions of 23% from Figure 13b, compares well with typical experimental values of about 20% [1].”
BackgroundMethodInfluentialSelf-citationNew ion trap for frequency standard applications
Prestage, J. D., Dick, G. J., & Maleki, L. (1989) · Journal of Applied Physics · doi:10.1063/1.343486 · Cited by 230 · cited 1×
“In the fringing region, the diminution of the quadrupole field, the increased significance of higher-order terms in the multipole expansion of the potential and coupling of radial and axial fields lead to significant changes in the secular frequency [6, 7] and thus ejection at unexpected stability coordinates.”
BackgroundHopfgartner, G., Husser, C., & Zell, M. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.420 · Cited by 129 · cited 2×
“capabilities to traditional RF/DC mass-filters [1, 4].”
Background
Cited by
Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
Collisional Cooling of Large Ions in Electrospray Mass Spectrometry
Chernushevich, I. V., & Thomson, B. A. (2004) · Analytical Chemistry · doi:10.1021/ac035406j · Cited by 235
Prakash, P., Manchanda, P., Paouri, E., Bisht, K., Sharma, K., Rajpoot, J., Wendt, V., Hossain, A., Wijewardhane, P. R., Randolph, C. E., et al. (2025) · Immunity · doi:10.1016/j.immuni.2025.04.029 · Cited by 152
Amyloid β Induces Lipid Droplet-Mediated Microglial Dysfunction in Alzheimer’s Disease
Prakash, P., Manchanda, P., Paouri, E., Bisht, K., Sharma, K., Rajpoot, J., Wendt, V., Hossain, A., Wijewardhane, P. R., Randolph, C. E., et al. (2023) · doi:10.1101/2023.06.04.543525 · Cited by 38
Metadata
- Authors
- Londry, F. A., & Hager, J. W.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-10-01
- Volume
- 14
- Issue
- 10
- Pages
- 1130-1147
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2030242280
- Cited by
- 204
- References
- 6
- FWCI
- 2.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mass selective axial ion ejection from a linear quadrupole ion trap. https://app.cochat.ai/papers/10.1016/s1044-0305(03)00446-x
- The paper
- Londry, F. A., & Hager, J. W. (2003). Mass selective axial ion ejection from a linear quadrupole ion trap. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/s1044-0305(03)00446-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.