The DOI matches its Crossref record.
A new linear ion trap mass spectrometer
Abstract
Characteristics of mass selective axial ion ejection from a linear quadrupole ion trap in the presence of an auxiliary quadrupole field are described. Ion ejection is shown to occur through coupling of radial and axial motion in the exit fringing fields of the linear ion trap. The coupling is efficient and can result in extraction of as much as 20% of the trapped ions. This, together with the very high trapping efficiencies, can yield high sensitivity mass spectral responses. The experimental apparatus is based on the ion path of a triple quadrupole mass spectrometer allowing either the q2 collision cell or the final mass analysis quadrupole to be used as the linear trap. Space charge induced distortions of the mass resolved features while using the pressurized q2 linear ion trap occur at approximately the same ion density as reported for conventional three‐dimensional ion traps. These distortions are, however, much reduced for the lower pressure linear trap possibly owing to the proposed axial ejection mechanism that leads to ion ejection only for ions of considerable radial amplitude. RF heating due to the high ejection q ‐value and the low collision frequency may also contribute. Two hybrid RF/DC quadrupole‐linear ion trap instruments are described that provide high sensitivity product ion scanning while operated in the linear ion trap mode while also retaining all conventional triple quadrupole scan modes such as precursor ion and neutral loss scan modes. Copyright © 2002 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Ishihama, Y., Oda, Y., Tabata, T., Sato, T., Nagasu, T., Rappsilber, J., & Mann, M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500061-mcp200 · Cited by 2,055
Miniature and Fieldable Mass Spectrometers: Recent Advances
Snyder, D. T., Pulliam, C. J., Ouyang, Z., & Cooks, R. G. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03070 · Cited by 420
Ouyang, Z., & Cooks, R. G. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-060908-155229 · Cited by 323
Olsen, J. V., & Mann, M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0405549101 · Cited by 313
Metadata
- Authors
- Hager, J. W.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2002-02-04
- Volume
- 16
- Issue
- 6
- Pages
- 512-526
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2164253249
- Cited by
- 479
- References
- 0
- FWCI
- 14.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new linear ion trap mass spectrometer. https://app.cochat.ai/papers/10.1002/rcm.607
- The paper
- Hager, J. W. (2002). A new linear ion trap mass spectrometer. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.607
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.