The DOI matches its Crossref record.
Quantitation of SR 27417 in human plasma using electrospray liquid chromatography-tandem mass spectrometry: A study of ion suppression
Abstract
The effect of coeluting matrix compounds on the quantitation of SR 27417 in human plasma using electrospray liquid chromatography-tandem mass spectrometry has been examined. During the method development stage of this assay, plasma samples spiked with the analyte at 100 pg/mL were extracted using three different procedures: a hexane liquid-liquid extraction, an ethyl acetate back-extraction, and a solid phase extraction. Ion intensity of the analyte was found to be related inversely to the percent ionization of coeluting matrix components as evidenced by full scan spectra. The ethyl acetate back-extraction, which contained the fewest coeluting components, resulted in the highest ion intensity for the analyte. An assay comparison was done by using the liquid-liquid hexane and the ethyl acetate back-extractions for sample preparation. Replicate 1-mL samples (n=5) at 11 concentrations from 5 to 2000 pg/mL were extracted and analyzed. The results for the ethyl acetate back-extracted samples were acceptable from 2000 to 5 pg/mL with accuracy ranging from -11.6 to 2.61% of the nominal concentrations. In contrast, the hexane liquid-liquid method had poor accuracy and precision below 20 pg/mL. The difference is explained by suppression of analyte ion intensity. These results are consistent with the current theory of electrospray ionization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bonfiglio, R., King, R. C., Olah, T. V., & Merkle, K. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990630)13:12<1175::aid-rcm639>3.0.co;2-0 · Cited by 939
Matrix effects in (ultra)trace analysis of pesticide residues in food and biotic matrices
Hajšlová, J., & Zrostlı́ková, J. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00539-9 · Cited by 441
Quantitative analysis of thyroid hormone metabolites in cell culture samples using LC-MS/MS
Rathmann, D., Rijntjes, E., Lietzow, J., & Köhrle, J. (2015) · European Thyroid Journal · doi:10.1159/000430840 · Cited by 34
Richards, K. H., Monk, R., Renko, K., Rathmann, D., Rijntjes, E., & Köhrle, J. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-01941-9 · Cited by 27
Richards, K. H., Schanze, N., Monk, R., Rijntjes, E., Rathmann, D., & Köhrle, J. (2017) · PLOS ONE · doi:10.1371/journal.pone.0183482 · Cited by 15
Metadata
- Authors
- Buhrman, D. L., Price, P. I., & Rudewiczcor, P. J.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-11-01
- Volume
- 7
- Issue
- 11
- Pages
- 1099-1105
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2079554237
- Cited by
- 364
- References
- 0
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitation of SR 27417 in human plasma using electrospray liquid chromatography-tandem mass spectrometry: A study of ion suppression. https://app.cochat.ai/papers/10.1016/s1044-0305(96)00072-4
- The paper
- Buhrman, D. L., Price, P. I., & Rudewiczcor, P. J. (1996). Quantitation of SR 27417 in human plasma using electrospray liquid chromatography-tandem mass spectrometry: A study of ion suppression. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/s1044-0305(96)00072-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.