Repeatability of surface EMG variables during voluntary isometric contractions of the biceps brachii muscle
The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Intraclass Correlation Coefficient as a Measure of Reliability
Bartko, J. J. (1966) · Psychological Reports · doi:10.2466/pr0.1966.19.1.3 · Cited by 2,299 · cited 1×
“It is current practice to accept as “excellent repeatability” ICC values in the range 80%–100% and “good repeatability” ICC values in the range 60%–80%, while values below 60% indicate “poor repeatability” [2].”
BackgroundMyoelectric manifestations of fatigue in voluntary and electrically elicited contractions
Merletti, R., Knaflitz, M., & De Luca, C. J. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.69.5.1810 · Cited by 610 · cited 4×
“During contractions sustained at high MVC fractions, the normalized rate of decrease of MNF is higher than that of CV [26], confirming previous observations that factors other than CV affect MNF or MDF [10,32,33,36].”
MethodResultSelf-citationEffects of muscle fiber type and size on EMG median frequency and conduction velocity
Kupa, E. J., Roy, S. H., Kandarian, S. C., & De Luca, C. J. (1995) · Journal of Applied Physiology · doi:10.1152/jappl.1995.79.1.23 · Cited by 458 · cited 1×
“These changes have been demonstrated to reflect muscle properties and fiber constituency [16,18,19,25, 33,44,46,48], recruitment strategies [3,43,45] and have been applied in ergonomics [13,22,23], back analysis [4,5,14,40,43] and dentistry [17].”
BackgroundDOWSE, T. S. (2013) · Lectures on Massage & Electricity · doi:10.1016/b978-1-4832-2804-4.50011-9 · Cited by 359
Andreassen, S., & Arendt-Nielsen, L. (1987) · The Journal of Physiology · doi:10.1113/jphysiol.1987.sp016756 · Cited by 353 · cited 3×
“According to the size principle [1] this fact may be due to the recruitment of motor units with progressively higher CV values, as confirmed by Solomonow et al.”
BackgroundResultElectromyogram power spectra frequencies associated with motor unit recruitment strategies
Solomonow, M., Baten, C., Smit, J., Baratta, R., Hermens, H., D'Ambrosia, R., & Shoji, H. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.3.1177 · Cited by 333 · cited 4×
“5) in agreement with the findings of others [3,45,46].”
BackgroundMethodResultInfluentialEffects of electrode location on myoelectric conduction velocity and median frequency estimates
Roy, S. H., De Luca, C. J., & Schneider, J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.61.4.1510 · Cited by 260 · cited 2×
“The high quality of estimate of EMG variables in biceps brachii is probably due to the long and parallel fibers of the muscle and to the availability of sufficient space to place the EMG electrodes between the motor points and the tendon endings [42].”
BackgroundMyoelectric signal conduction velocity and spectral parameters: influence of force and time
Broman, H., Bilotto, G., & De Luca, C. J. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.58.5.1428 · Cited by 260 · cited 2×
“During contractions sustained at high MVC fractions, the normalized rate of decrease of MNF is higher than that of CV [26], confirming previous observations that factors other than CV affect MNF or MDF [10,32,33,36].”
MethodResultUse of the surface EMG signal for performance evaluation of back muscles
De Luca, C. J. (1993) · Muscle & Nerve · doi:10.1002/mus.880160216 · Cited by 254
Fibre conduction velocity and fibre composition in human vastus lateralis
Sadoyama, T., Masuda, T., Miyata, H., & Katsuta, S. (1988) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf01076001 · Cited by 224
Cited by
The extraction of neural strategies from the surface EMG
Farina, D., Merletti, R., & Enoka, R. M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01070.2003 · Cited by 1,573
“Furthermore, the diversity of experimental findings on changes in mean or median frequency with increasing force underscores the equivocal basis of this approach; there are reports of an increase in the spectral variables with increasing force level (36, 60), no increase in these variables with force (67, 78), and a d…”
Self-citationNeural Adaptations to Resistive Exercise: Mechanisms and Recommendations for Training Practices
Gabriel, D. A., Kamen, G., & Frost, G. (2006) · Sports Medicine · doi:10.2165/00007256-200636020-00004 · Cited by 794
Motor unit recruitment strategies investigated by surface EMG variables
Farina, D., Fosci, M., & Merletti, R. (2002) · Journal of Applied Physiology · doi:10.1152/jappl.2002.92.1.235 · Cited by 318
Self-citationThe Usefulness of Mean and Median Frequencies in Electromyography Analysis
Phinyomark, A., Thongpanja, S., Hu, H., Phukpattaranont, P., & Limsakul, C. (2012) · Computational Intelligence in Electromyography Analysis - A Perspective on Current Applications and Future Challenges · doi:10.5772/50639 · Cited by 294
Falla, D., Jull, G., Dall'Alba, P., Rainoldi, A., & Merletti, R. (2003) · Physical Therapy · doi:10.1093/ptj/83.10.899 · Cited by 206
Self-citationFarina, D., Muhammad, W., Fortunato, E., Meste, O., Merletti, R., & Rix, H. (2001) · Medical and Biological Engineering and Computing · doi:10.1007/bf02344807 · Cited by 181
Self-citationAssociations between motor unit action potential parameters and surface EMG features
Del Vecchio, A., Negro, F., Felici, F., & Farina, D. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00482.2017 · Cited by 176
Buckthorpe, M. W., Hannah, R., Pain, T. G., & Folland, J. P. (2012) · Muscle & Nerve · doi:10.1002/mus.23322 · Cited by 168
“Alternatively, DeLuca(25) suggested that sub-maximal contractions at 80% MVF may provide more stable EMG amplitude than MVCs, and there is evidence that the EMG amplitude during submaximal contractions exhibits superior betweensession reliability.(30,31) Furthermore, the EMG response to an evoked maximal compound musc…”
BackgroundMeasurement of EMG activity with textile electrodes embedded into clothing
Finni, T., Hu, M., Kettunen, P., Vilavuo, T., & Cheng, S. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/11/007 · Cited by 160
“Partly the variation may also be due to some degree of fatigue cumulated from previous contractions (Rainoldi et al 1999).”
BackgroundMuscle fatigue induced by two different resistances: Elastic tubing versus weight machines
Melchiorri, G., & Rainoldi, A. (2011) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2011.07.015 · Cited by 82
“The time course of each EMG variable was normalised with respect to the intercept of the regression line to produce a ‘‘fatigue plot’’ (Rainoldi et al., 1999).”
MethodSelf-citationThe acute effect of Quercetin on muscle performance following a single resistance training session
Patrizio, F., Ditroilo, M., Felici, F., Duranti, G., De Vito, G., Sabatini, S., Sacchetti, M., & Bazzucchi, I. (2018) · European Journal of Applied Physiology · doi:10.1007/s00421-018-3834-y · Cited by 46
Silva, D. C. D. O., Silva, Z., Sousa, G. D. C., Silva, L. F. G. E., Marques, K. D. V., Soares, A. B., Cerqueira, E. P., Liberti, E. A., & Bérzin, F. (2009) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.09.014 · Cited by 13
Metadata
- Authors
- Rainoldi, A., Galardi, G., Maderna, L., Comi, G., Lo Conte, L., & Merletti, R.
- Venue
- Journal of Electromyography and Kinesiology
- Publisher
- Elsevier BV
- Published
- 1999-04
- Volume
- 9
- Issue
- 2
- Pages
- 105-119
- ISSN
- 1050-6411 (ISSN-L)
- OpenAlex
- W2097535105
- Cited by
- 203
- References
- 39
- FWCI
- 4.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.