The DOI matches its Crossref record.
Effects of electrode location on myoelectric conduction velocity and median frequency estimates
Abstract
The effect of surface electrode location on the estimates of the median frequency and conduction velocity of the myoelectric signal was investigated. The locations were identified with respect to the innervation zone and the tendonous portion of the tibialis anterior muscle. Considerable modifications in the median frequency and conduction velocity parameters were noted. The highest values of the median frequency occurred at the region of the innervation zone and tendonous insertion of the muscle, and decreased proportionally with distance from these areas. The rate of change of median frequency was not effected by electrode location. Estimates of conduction velocity were most stable in a region between the distal tendon and the adjacent innervation zone. This region also provided the best linear fit when comparing conduction velocity to median frequency estimates. The implications for signal detection procedures are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The extraction of neural strategies from the surface EMG
Farina, D., Merletti, R., & Enoka, R. M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01070.2003 · Cited by 1,573
Effects of muscle fiber type and size on EMG median frequency and conduction velocity
Kupa, E. J., Roy, S. H., Kandarian, S. C., & De Luca, C. J. (1995) · Journal of Applied Physiology · doi:10.1152/jappl.1995.79.1.23 · Cited by 458
Self-citationInterpretation of EMG changes with fatigue: facts, pitfalls, and fallacies
Dimitrova, N. A., & Dimitrov, G. V. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00083-4 · Cited by 458
The linear electrode array: a useful tool with many applications
Merletti, R., Farina, D., & Gazzoni, M. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00082-2 · Cited by 285
Young, A. J., Hargrove, L. J., & Kuiken, T. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2159216 · Cited by 287
Metadata
- Authors
- Roy, S. H., De Luca, C. J., & Schneider, J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1986-10-01
- Volume
- 61
- Issue
- 4
- Pages
- 1510-1517
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2132481753
- Cited by
- 260
- References
- 0
- FWCI
- 3.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of electrode location on myoelectric conduction velocity and median frequency estimates. https://app.cochat.ai/papers/10.1152/jappl.1986.61.4.1510
- The paper
- Roy, S. H., De Luca, C. J., & Schneider, J. (1986). Effects of electrode location on myoelectric conduction velocity and median frequency estimates. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1986.61.4.1510
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.