Relationship between EMG signals and force in human vastus lateralis muscle using multiple bipolar wire electrodes
Abstract
This paper describes the relationship between knee extension force and EMG signals detected by multiple bipolar wire electrodes inserted into the human vastus lateralis muscle under isometric conditions. Six healthy male volunteers participated in this study. Eight pairs of bipolar wire electrodes were inserted into the right vastus lateralis muscle and the EMG data were simultaneously detected and analyzed. The EMG raw data and individual force-IEMG relations were influenced by the location of the electrode inserted into the muscle. The force and IEMG relationship averaged across subjects detected from the eight electrodes, however, showed almost the same linear correlation in spite of different electrode locations. No linear correlation was observed between MdF and the knee extension force. This result suggests that, if all of the muscle fibers participate in the same action at the same time, the averaged normalized IEMG from any places using wire electrodes could reflect the total activities of that muscle even if the muscle is large.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A final issue with percutaneous electrodes is that muscle contractions may result in eventual breakage, although these problems have become less frequent with the improvement of electrodes and lead wires.
“A final issue with percutaneous electrodes is that muscle contractions may result in eventual breakage, although these problems have become less frequent with the improvement of electrodes and lead wires”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Onishi et al., 2000
Biomechanical studies show that under isometric contractions the relationship between force and EMG can be considered linear.
“This approach is supported by biomechanical studies (Hof, 1997; Onishi et al., 2000) showing that under isometric contractions the relationship between force and EMG can be considered linear.”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Onishi et al., 2000
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
References 28 · Cited by 105
- Authors
- Onishi, H., Yagi, R., Akasaka, K., Momose, K., Ihashi, K., & Handa, Y.
- Affiliations
- Tohoku University (JP)
- Corresponding author
- Onishi, H
- Venue
- Journal of Electromyography and Kinesiology
- Publisher
- Elsevier BV
- Published
- 2000-02
- Volume
- 10
- Issue
- 1
- Pages
- 59-67
- ISSN
- 1050-6411 (ISSN-L)
- OpenAlex
- W2026202924
- Cited by
- 105
- References
- 28
- Citations by year
- 2026: 5 · 2025: 7 · 2024: 4 · 2023: 4 · 2022: 3 · 2021: 4 · 2020: 2 · 2019: 5 · 2018: 4 · 2017: 3 · 2016: 4 · 2015: 8 · 2014: 7 · 2013: 6 · 2012: 5
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Electromyography and Kinesiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Muscle Physiology and Disorders
- Keywords
- vastus lateralis, knee extension force, isometric contraction, surface electromyography, electrode placement, muscle force, muscle fiber recruitment
- MeSH terms
- Adult, Electromyography, Hip Joint, Humans, Isometric Contraction, Male, Muscle, Skeletal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review