Clinical Staging of Esophageal Carcinoma: CT, EUS, and PET
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
CT is readily available to all patients. It is relatively inexpensive and fees are usually reimbursed. It provides exquisite anatomic detail of the chest and abdomen in patients with esophageal cancer. The only reliable use of CT in the determination of T is the exclusion of T4 tumors, which is suggested by the preservation of fat planes. Enlarged lymph nodes are suspicious for metastatic disease but require further study or tissue sampling if nodal metastases will determine treatment. Its major use is in the detection of distant metastatic disease; however, 30% to 60% of distant metastases may be radiographically occult. There is a significant learning curve for EUS staging of esophageal cancer. It is suggested that this study be performed at institutions where there is a dedicated, experienced endoscopic ultrasonographer with adequate instrumentation that allows specialty imaging and EUS-FNA. EUS is the best means of clinically determining T. The addition of EUS-FNA to routine EUS evaluation of lymph nodes allows an accuracy similar to the EUS determination of T. EUS has no purpose in assessment of non-nodal distant metastatic disease; however, the serendipitous finding of distant metastases in adjacent structures visualized during the evaluation of the primary tumor and lymph nodes has, on occasion, detected M1b disease. FDG-PET represents an advance over CT scanning in the screening for distant metastases. The major problems with FDG-PET staging of esophageal cancer is failure to detect metastatic deposits less than 1 cm in diameter and lack of anatomic definition. It is unable to determine T and has been inaccurate in the detection of lymph node metastases. Because this test is not readily available, is expensive, and is not routinely reimbursed, its use in staging esophageal cancer continues to be limited. Today, CT and EUS are the mainstays in the clinical staging of esophageal carcinoma. When possible, FDG-PET should be added to CT to improve the evaluation of non-nodal M1b disease. Results of these studies should determine the necessity for invasive staging techniques and direct their use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Endosonography-guided fine-needle aspiration biopsy: Diagnostic accuracy and complication assessment
Wiersema, M., Vilmann, P., Giovannini, M., Chang, K., & Wiersema, L. (1997) · Gastroenterology · doi:10.1016/s0016-5085(97)70164-1 · Cited by 1,131
Esophageal Carcinoma: Depth of Tumor Invasion Is Predictive of Regional Lymph Node Status
Rice, T. W., Zuccaro, G., Adelstein, D. J., Rybicki, L. A., Blackstone, E. H., & Goldblum, J. R. (1998) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(97)01387-8 · Cited by 362
Self-citationStaging of esophageal cancer with 18F-fluorodeoxyglucose positron emission tomography.
Flanagan, F. L., Dehdashti, F., Siegel, B. A., Trask, D. D., Sundaresan, S. R., Patterson, G. A., & Cooper, J. D. (1997) · American Journal of Roentgenology · doi:10.2214/ajr.168.2.9016218 · Cited by 312
Improvement in Staging of Esophageal Cancer With the Addition of Positron Emission Tomography
Block, M. I., Patterson, G. A., Sundaresan, R. S., Bailey, M. S., Flanagan, F. L., Dehdashti, F., Siegel, B. A., & Cooper, J. D. (1997) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(97)00619-x · Cited by 259
Role of Positron Emission Tomography in Staging Esophageal Cancer
Luketich, J. D., Schauer, P. R., Meltzer, C. C., Landreneau, R. J., Urso, G. K., Townsend, D. W., Ferson, P. F., Keenan, R. J., & Belani, C. P. (1997) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(97)00624-3 · Cited by 207
Positron emission tomography for staging of oesophageal and gastroesophageal malignancy
Kole, A., Plukker, J., Nieweg, O., & Vaalburg, W. (1998) · British Journal of Cancer · doi:10.1038/bjc.1998.526 · Cited by 186
Rankin, S., Taylor, H., Cook, G., & Mason, R. C. (1998) · Clinical Radiology · doi:10.1016/s0009-9260(98)80292-4 · Cited by 153
Cited by
Clinical Applications of PET in Oncology
Rohren, E. M., Turkington, T. G., & Coleman, R. E. (2004) · Radiology · doi:10.1148/radiol.2312021185 · Cited by 859
Blodgett, T. M., Meltzer, C. C., & Townsend, D. W. (2007) · Radiology · doi:10.1148/radiol.2422051113 · Cited by 387
van Westreenen, H. L., Westerterp, M., Bossuyt, P. M. M., Pruim, J., Sloof, G. W., van Lanschot, J. J. B., Groen, H., & Plukker, J. T. M. (2004) · Journal of Clinical Oncology · doi:10.1200/jco.2004.01.083 · Cited by 370
PET/CT of Esophageal Cancer: Its Role in Clinical Management
Bruzzi, J. F., Munden, R. F., Truong, M. T., Marom, E. M., Sabloff, B. S., Gladish, G. W., Iyer, R. B., Pan, T.-S., Macapinlac, H. A., & Erasmus, J. J. (2007) · RadioGraphics · doi:10.1148/rg.276065742 · Cited by 166
Metadata
- Authors
- Rice, T. W.
- Venue
- Chest Surgery Clinics of North America
- Publisher
- Elsevier BV
- Published
- 2000-08
- Volume
- 10
- Issue
- 3
- Pages
- 471-485
- ISSN
- 1052-3359 (ISSN-L)
- OpenAlex
- W185986358
- Cited by
- 158
- References
- 7
- FWCI
- 6.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.