Comparison of cardiac output assessed by pulse-contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Yearbook of Intensive Care and Emergency Medicine 2002
(2002) · Springer eBooks · doi:10.1007/978-3-642-56011-8 · Cited by 876
Tracer kinetic methods in medical physiology
Lassen, N. A., & Perl, W. (1979) · Raven Press eBooks · Cited by 540
Continuous thermodilution cardiac output measurement in intensive care unit patients
Yelderman, M., Ramsay, M. A., Quinn, M. D., Paulsen, A. W., McKown, R. C., & Ph, G. (1992) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/1053-0770(92)90137-v · Cited by 160
Gayes, J. M., Emery, R. W., & Nissen, M. D. (1996) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(05)80019-9 · Cited by 57
Hogue, C. W. J., Rosenbloom, M., McCawley, C., & Lappas, D. G. (1994) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/1053-0770(94)90193-7 · Cited by 46
Transpulmonary Indicator Dilution: An Alternative Approach for Hemodynamic Monitoring
Hoeft, A. (1995) · Yearbook of intensive care and emergency medicine · doi:10.1007/978-3-642-79154-3_48 · Cited by 37
Continuous determination of cardiac output using a flow-directed doppler pulmonary artery catheter
Segal, J., Gaudiani, V. A., & Nishimura, T. G. (1991) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/1053-0770(91)90151-i · Cited by 26
Cited by
Stroke Volume Variation as a Predictor of Fluid Responsiveness in Patients Undergoing Brain Surgery
Berkenstadt, H., Margalit, N., Hadani, M., Friedman, Z., Segal, E., Villa, Y., & Perel, A. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200104000-00034 · Cited by 412
Cardiovascular management of septic shock
Dellinger, R. P. (2003) · Critical Care Medicine · doi:10.1097/01.ccm.0000057403.73299.a6 · Cited by 369
Physiological changes of pregnancy and monitoring
Carlin, A., & Alfirevic, Z. (2008) · Best Practice & Research Clinical Obstetrics & Gynaecology · doi:10.1016/j.bpobgyn.2008.06.005 · Cited by 310
Della Rocca, G., Costa, M. G., Pompei, L., Coccia, C., & Pietropaoli, P. (2002) · British Journal of Anaesthesia · doi:10.1093/bja/88.3.350 · Cited by 239
Minimally Invasive Cardiac Output Monitoring in the Perioperative Setting
Funk, D. J., Moretti, E. W., & Gan, T. J. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31818ffd99 · Cited by 202
“The accuracy of CO measurement remained despite changes induced with esmolol in one study.(64) However, in another study with cardiac surgical patients, the CO lost its correlation with PACTD-derived CO when SVR was artificially increased with phenylephrine.”
Method
Metadata
- Authors
- Buhre, W., Weyland, A., Kazmaier, S., Hanekop, G. G., Baryalei, M. M., Sydow, M., & Sonntag, H.
- Venue
- Journal of Cardiothoracic and Vascular Anesthesia
- Publisher
- Elsevier BV
- Published
- 1999-08
- Volume
- 13
- Issue
- 4
- Pages
- 437-440
- ISSN
- 1053-0770 (ISSN-L)
- OpenAlex
- W1994495872
- Cited by
- 161
- References
- 9
- FWCI
- 6.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.