Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 412

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Stroke Volume Variation as a Predictor of Fluid Responsiveness in Patients Undergoing Brain Surgery

Berkenstadt, Haim, Margalit, Nevo, Hadani, Moshe, Friedman, Zeev, Segal, Eran, Villa, Yael, Perel, Azriel·2001·Anesthesia & Analgesia

Abstract

UNLABELLED: Changes in arterial blood pressure induced by mechanical ventilation allow assessment of cardiac preload. In this study, stroke volume variation (SVV), which is the percentage change between the maximal and minimal stroke volumes (SV) divided by the average of the minimum and maximum over a floating period of 30 s, continuously displayed by the PiCCO continuous cardiac output monitor, was evaluated as a predictor of fluid responsiveness. Fifteen patients undergoing brain surgery were included. During surgery, graded volume loading was performed with each volume loading step (VLS) consisting of 100 mL of 6% hydroxyethylstarch given for 2 min. Successive responsive VLSs were performed (increase in SV > 5% after a VLS) until a change in SV of < 5 % was reached (nonresponsive). A total of 140 VLSs were performed. Responsive and nonresponsive VLSs differed in their pre-VLS values of systolic blood pressure, SV, and SVV, but not in the values of heart rate and central venous pressure. By using receiver operating characteristic analysis, the area under the curve for SVV (0.870, 95% confidence interval [CI]: 0.809 to 0.903) was statistically more than those for central venous pressure (0.493, 95% CI: 0.397 to 0.590, P = 7 x 10(-10)), heart rate (0.593, 95% CI: 0.443 to 0.635, P = 5.7 x 10(-10)), and systolic blood pressure (0.729, 95% CI: 0.645 to 0.813, P: = 4.3 x 10(-3)). An SVV value of 9.5% or more, will predict an increase in the SV of at least 5% in response to a 100-mL volume load, with a sensitivity of 79% and a specificity of 93%. IMPLICATIONS: Stroke volume variation may be used as a continuous preload variable and in combination with the continuously measured cardiac output, defining on-line the most important characteristics of cardiac function, allowing for optimal fluid management.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000539-200104000-00034

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 412

Metadata

Authors
Berkenstadt, H., Margalit, N., Hadani, M., Friedman, Z., Segal, E., Villa, Y., & Perel, A.
Venue
Anesthesia & Analgesia
Published
2001-04
Volume
92
Issue
4
Pages
984-989
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2040491697
Cited by
412
References
12
FWCI
10.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stroke Volume Variation as a Predictor of Fluid Responsiveness in Patients Undergoing Brain Surgery. https://app.cochat.ai/papers/10.1097/00000539-200104000-00034
The paper
Berkenstadt, H., Margalit, N., Hadani, M., Friedman, Z., Segal, E., Villa, Y., & Perel, A. (2001). Stroke Volume Variation as a Predictor of Fluid Responsiveness in Patients Undergoing Brain Surgery. Anesthesia & Analgesia. https://doi.org/10.1097/00000539-200104000-00034

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.