Cited by 71Diabetes Management and ResearchDiabetes Treatment and ManagementDiabetes Management and Education

A comparison of insulin lispro and buffered regular human insulin administered via continuous subcutaneous insulin infusion pump

Raskin, Philip, Holcombe, John H, Tamborlane, William V, Malone, John I, Strowig, Suzanne, Ahern, Jo Ann, Lavent, Francine·2001·Journal of Diabetes and its Complications

Abstract

This study compared glycemic control achieved with insulin lispro or buffered regular human insulin in patients with Type 1 diabetes treated with continuous subcutaneous insulin infusion (CSII) using an external insulin pump. In this 24-week multicenter, randomized, two-way crossover, open-label trial, 58 patients on CSII with adequate glycemic control received either insulin lispro or buffered regular human insulin for 12 weeks, followed by the alternate treatment for another 12 weeks. Efficacy and safety measures included hemoglobin A(1c) (HbA(1c)) at baseline and endpoint, home blood glucose monitoring, hypoglycemia, and frequency of pump catheter occlusion. Patients consumed a standard test meal on three occasions, with determinations of fasting, 1- and 2-h postprandial glucose values. Insulin lispro use was associated with a significantly lower HbA(1c) than was buffered regular human insulin (7.41+/-0.97 vs. 7.65+/-0.85 mmol/l; P=.004). Fasting serum glucose values before the test meal were similar between the two therapies. The 1-h (11.16+/-4.29 vs. 13.20+/-4.68 mmol/l; P=.012) and 2-h (9.64+/-4.10 vs. 12.53+/-4.64 mmol/l; P=.001) postprandial glucose concentrations were significantly lower during treatment with insulin lispro. No differences between treatments were observed in basal or bolus insulin doses, weight gain, or the incidence and rate of hypoglycemia, hyperglycemia, or pump occlusions. When used in external pumps, insulin lispro provides better glycemic contr…

Integrity signals

Registry

Crossref · 10.1016/s1056-8727(01)00168-4

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The patent literature contains information about occlusion detection systems from at least 400 patents from 1971 through 2016.

    “The patent literature contains information about occlusion detection systems from at least 400 patents from 1971 through 2016.5”
  • Occlusion detection by infusion pumps may depend on detecting increased pressure in the tubing, increased radial diameter of the tubing, lack of a temperature gradient of heated fluid, lack of optical signals from an inline piston, or an unexplained rise in the concentration of interstitial fluid glucose.

    “Occlusion detection by infusion pumps may depend on detecting increased pressure in the tubing, increased radial diameter of the tubing, lack of a temperature gradient of heated fluid, lack of optical signals from an inline piston, or an unexplained rise in the concentration of interstitial fluid glucose.5”

The citation lists haven’t been fetched yet

References 25 · Cited by 71

Authors
Raskin, P., Holcombe, J. H., Tamborlane, W. V., Malone, J. I., Strowig, S., Ahern, J. A., & Lavent, F.
Affiliations
  • The University of Texas Southwestern Medical Center (US)
  • Eli Lilly (United States) (US)
  • Yale University (US)
  • University of South Florida (US)
Corresponding author
Raskin, Philip
Venue
Journal of Diabetes and its Complications
Publisher
Elsevier BV
Published
2001-11
Volume
15
Issue
6
Pages
295-300
ISSN
  • 0891-6632 (ISSN-L)
  • 1056-8727
OpenAlex
W2145012784
Cited by
71
References
25
Citations by year
2026: 1 · 2024: 2 · 2023: 1 · 2022: 2 · 2021: 2 · 2019: 4 · 2018: 2 · 2017: 1 · 2016: 1 · 2015: 1 · 2013: 2 · 2012: 5
FWCI
3.68
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Diabetes and its Complications (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
Keywords
insulin lispro, insulin pump therapy, type 1 diabetes, glycemic control, HbA1c, postprandial blood glucose, hypoglycemia, insulin analogues
MeSH terms
Adult, Blood Glucose, Diabetes Mellitus, Type 1, Equipment Failure, Fasting, Female, Food, Glycated Hemoglobin, Humans, Hypoglycemia, Insulin, Insulin Infusion Systems, Male, Middle Aged, Blood Glucose Self-Monitoring, Cross-Over Studies, Insulin Lispro

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›