Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Microalbuminuria in diabetes mellitus: efficacy of a new screening method in comparison with timed overnight urine collection

Meinhardt, U · 2003 · Journal of Diabetes and its Complications

Abstract

Diabetic nephropathy and end-stage renal failure are still a major cause of mortality amongst patients with diabetes mellitus (DM). In this study, we evaluated the Clinitek-Microalbumin (CM) screening test strip for the detection of microalbuminuria (MA) in a random morning spot urine in comparison with the quantitative assessment of albuminuria in the timed overnight urine collection ("gold standard"). One hundred thirty-four children, adolescents, and young adults with insulin-dependent DM Type 1 were studied at 222 outpatient visits. Because of urinary tract infection and/or haematuria, the data of 13 visits were excluded. Finally, 165 timed overnight urine were collected in the remaining 209 visits (79% sample per visit rate). Ten (6.1%) patients presented MA of > or =15 microg/min. In comparison however, 200 spot urine could be screened (96% sample/visit rate) yielding a significant increase in compliance and screening rate (P or =30 mg albumin/l) were 0.89 [95% confidence interval (CI) 0.56-0.99] and 0.73 (CI 0.66-0.80), respectively. The positive and negative predictive value were 0.17 (CI 0.08-0.30) and 0.99 (CI 0.95-1.00), respectively. Considering CM albumin-to-creatinine ratio, the results were poorer than with the albumin concentration alone. Using CM instead of quantitative assessment of albuminuria is not cost-effective (35 US dollars versus 60 US dollars/patient/year). In conclusion, to exclude MA, the CM used in the random spot urine is reliable and easy to ha…

Overview

Integrity signals

Registry

Crossref · 10.1016/s1056-8727(02)00180-0

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 12 references

Cited by

See all 38

Metadata

Authors
Meinhardt, U.
Affiliations
University Hospital of Bern (CH)
Corresponding author
Meinhardt, U
Venue
Journal of Diabetes and its Complications
Publisher
Elsevier BV
Published
2003-10
Volume
17
Issue
5
Pages
254-257
ISSN
  • 0891-6632 (ISSN-L)
  • 1056-8727
OpenAlex
W2070864090
Cited by
38
References
12
Citations by year
2026: 1 · 2024: 2 · 2023: 3 · 2022: 1 · 2021: 5 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 1 · 2013: 1 · 2012: 3
FWCI
1.71
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • Journal of Diabetes and its Complications (publishedVersion)
  • PubMed (publishedVersion)
  • BORIS (University Library Bern) (submittedVersion)
Topics
  • Health Sciences › Medicine › Nephrology › Chronic Kidney Disease and Diabetes
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Nephrology › Acute Kidney Injury Research
Keywords
microalbuminuria, type 1 diabetes, diabetic nephropathy, albumin-creatinine ratio, screening sensitivity and specificity, pediatric diabetes, screening adherence, cost-effectiveness
MeSH terms
Adolescent, Albuminuria, Child, Diabetes Mellitus, Type 1, Diabetic Nephropathies, Female, Humans, Kidney Failure, Chronic, Male, Mass Screening, Specimen Handling, Age of Onset

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microalbuminuria in diabetes mellitus: efficacy of a new screening method in comparison with timed overnight urine collection. https://app.cochat.ai/papers/10.1016/s1056-8727(02)00180-0
The paper
Meinhardt, U. (2003). Microalbuminuria in diabetes mellitus: efficacy of a new screening method in comparison with timed overnight urine collection. Journal of Diabetes and its Complications. https://doi.org/10.1016/s1056-8727(02)00180-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.