Abstract
BACKGROUND: Technical performance has traditionally been assessed subjectively within the operating theater, with few successful attempts at objective analysis. The Imperial College Surgical Assessment Device (ICSAD) has already been shown to be a valid quantitative measure of dexterity in laparoscopic surgical simulation. We describe its application to the assessment of open surgical procedures. STUDY DESIGN: Fifty-one participants were recruited from four different levels of general surgical experience: basic surgical trainees (n = 12), junior specialist registrars (n = 13), senior specialist registrars (n = 13), and consultants (n = 13). They completed two tasks: a small bowel anastomosis and a vein patch insertion into an artery. Surgical performance was measured with the Imperial College Surgical Assessment Device, a motion analysis system that measures the number of hand movements made and time taken to complete a task. The four groups were compared statistically using the Kruskal-Wallis test (K-W). Pairwise group comparisons used the Mann-Whitney U test and p values were adjusted for multiple comparisons to determine the statistical significance of these comparisons. RESULTS: Mean values for number of movements and time (secs) for small bowel anastomosis were 2,080/1,236 (basic surgical trainees), 1,673/1,016 (junior specialist registrars), 1,375/862 (senior specialist registrars), and 1,337/782 (consultants), respectively. Comparison of the medians by K-W revealed a p < 0.001 for each variable (No. of movements, time), respectively. Mean vein patch insertion results were 1,653/1,258, 1,297/1,006, 1,090/912, and 925/736 for each of the four groups. Again, comparison of the medians by K-W revealed a p < 0.001 for each variable. CONCLUSIONS: These findings suggest that hand motion analysis may be an effective objective measure of dexterity in open surgical simulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Objective structured assessment of technical skill (OSATS) for surgical residents
Martin, J. A., Regehr, G., Reznick, R., Macrae, H., Murnaghan, J., Hutchison, C., & Brown, M. (1997) · British Journal of Surgery · doi:10.1002/bjs.1800840237 · Cited by 2,527
Testing technical skill via an innovative “bench station” examination
Reznick, R., Regehr, G., MacRae, H., Martin, J., & McCulloch, W. (1997) · The American Journal of Surgery · doi:10.1016/s0002-9610(97)89597-9 · Cited by 1,048
Darzi, A., Smith, S., & Taffinder, N. (1999) · BMJ · doi:10.1136/bmj.318.7188.887 · Cited by 347
Self-citationSmith, R. (1998) · BMJ · doi:10.1136/bmj.316.7149.1917 · Cited by 310
Taffinder, N., Sutton, C., Fishwick, R. J., C, M. I., & Darzi, A. (1998) · Studies in Health Technology and Informatics · doi:10.3233/978-1-60750-894-6-124 · Cited by 263
Cited by
Teaching Surgical Skills — Changes in the Wind
Reznick, R. K., & MacRae, H. (2006) · New England Journal of Medicine · doi:10.1056/nejmra054785 · Cited by 1,761
Objective assessment of technical skills in surgery
Moorthy, K., Munz, Y., Sarker, S. K., & Darzi, A. (2003) · BMJ · doi:10.1136/bmj.327.7422.1032 · Cited by 651
Self-citationObjective assessment of technical surgical skills
van Hove, P. D., Tuijthof, G. J. M., Verdaasdonk, E. G. G., Stassen, L. P. S., & Dankelman, J. (2010) · British Journal of Surgery · doi:10.1002/bjs.7115 · Cited by 495
Gofton, W. T., Dudek, N. L., Wood, T. J., Balaa, F., & Hamstra, S. J. (2012) · Academic Medicine · doi:10.1097/acm.0b013e3182677805 · Cited by 314
Seymour, N. E. (2008) · World Journal of Surgery · doi:10.1007/s00268-007-9307-9 · Cited by 309
Xeroulis, G. J., Park, J., Moulton, C.-A., Reznick, R. K., LeBlanc, V., & Dubrowski, A. (2007) · Surgery · doi:10.1016/j.surg.2006.09.012 · Cited by 298
A Dataset and Benchmarks for Segmentation and Recognition of Gestures in Robotic Surgery
Ahmidi, N., Tao, L., Sefati, S., Gao, Y., Lea, C., Haro, B. B., Zappella, L., Khudanpur, S., Vidal, R., & Hager, G. D. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2647680 · Cited by 289
Transferring simulated arthroscopic skills to the operating theatre: A RANDOMISED BLINDED STUDY
Howells, N. R., Gill, H. S., Carr, A. J., Price, A. J., & Rees, J. L. (2008) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.90b4.20414 · Cited by 267
Cook, D. A., Brydges, R., Zendejas, B., Hamstra, S. J., & Hatala, R. (2013) · Academic Medicine · doi:10.1097/acm.0b013e31828ffdcf · Cited by 267
Towards automatic skill evaluation: Detection and segmentation of robot-assisted surgical motions
Lin, H. C., Shafran, I., Yuh, D., & Hager, G. D. (2006) · Computer Aided Surgery · doi:10.3109/10929080600989189 · Cited by 254
Review of methods for objective surgical skill evaluation
Reiley, C. E., Lin, H. C., Yuh, D. D., & Hager, G. D. (2011) · Surgical Endoscopy · doi:10.1007/s00464-010-1190-z · Cited by 249
“ICSAD assessment has shown construct validity, where these metrics improve with surgical experience [52].”
MethodInfluentialPorte, M. C., Xeroulis, G., Reznick, R. K., & Dubrowski, A. (2007) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2006.03.016 · Cited by 240
“hown to be construct valid, inferred by the procedure’s bility to differentiate between varying levels of experience, n both open surgical and laproscopic tasks [5,6].”
BackgroundObservational tools for assessment of procedural skills: a systematic review
Ahmed, K., Miskovic, D., Darzi, A., Athanasiou, T., & Hanna, G. B. (2011) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2010.10.020 · Cited by 227
Self-citationSurgical Skills Training and Simulation
Tsuda, S., Scott, D., Doyle, J., & Jones, D. B. (2009) · Current Problems in Surgery · doi:10.1067/j.cpsurg.2008.12.003 · Cited by 206
Assessing the Skills of Surgical Residents Using Simulation
Tavakol, M., Mohagheghi, M. A., & Dennick, R. (2008) · Journal of Surgical Education · doi:10.1016/j.jsurg.2007.11.003 · Cited by 195
Cognitive task analysis for teaching technical skills in an inanimate surgical skills laboratory
Velmahos, G. C., Toutouzas, K. G., Sillin, L. F., Chan, L., Clark, R. E., Theodorou, D., & Maupin, F. (2004) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2002.12.005 · Cited by 189
“Psychomotor skills evaluation was not used [20].”
Assessment of procedural skills in anaesthesia
Bould, M. D., Crabtree, N. A., & Naik, V. N. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep241 · Cited by 180
The simulated operating theatre: comprehensive training for surgical teams
Aggarwal, R. (2004) · Quality and Safety in Health Care · doi:10.1136/qhc.13.suppl_1.i27 · Cited by 180
Framework for Systematic Training and Assessment of Technical Skills
Aggarwal, R., Grantcharov, T. P., & Darzi, A. (2007) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2007.01.016 · Cited by 177
Self-citationModeling Surgical Technical Skill Using Expert Assessment for Automated Computer Rating
Azari, D. P., Frasier, L. L., Quamme, S. R. P., Greenberg, C. C., Pugh, C. M., Greenberg, J. A., & Radwin, R. G. (2019) · Annals of Surgery · doi:10.1097/sla.0000000000002478 · Cited by 84
Metadata
- Authors
- Datta, V., Mackay, S., Mandalia, M., & Darzi, A.
- Venue
- Journal of the American College of Surgeons
- Published
- 2001-11
- Volume
- 193
- Issue
- 5
- Pages
- 479-485
- ISSN
- 1072-7515 (ISSN-L)
- OpenAlex
- W1575406964
- Cited by
- 415
- References
- 5
- FWCI
- 8.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.