A ‘litmus test’ for molecular recognition using artificial membranes
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
BACKGROUND Sensitive and selective molecular recognition is important throughout biology. Certain organisms and toxins use specific binding at the cell surface as a first step towards invasion. A new series of biomolecular materials, with novel optical and interfacial properties, have been designed to sense molecular recognition events. These polymers, the diacetylenic lipids, have previously been shown to undergo chromatic transitions in response to virus binding to the surface of the material. RESULTS Gangliosides that specifically bind cholera toxin, heat-labile Escherichia coli enterotoxin and botulinum neurotoxin were incorporated into a matrix of diacetylenic lipids, 5-10% of which were derivatized with sialic acid. The lipids were self-assembled into Langmuir-Blodgett layers and polymerized with ultraviolet irradiation, yielding a polydiacetylene membrane with a characteristic blue color into which the ganglioside is non-covalently incorporated. When toxin is added, the polymerized membrane turns red. The response is specific and selective, and can be quantified by visible absorption spectrophotometry. CONCLUSIONS Polydiacetylenic lipid membranes offer a general 'litmus test' for molecular recognition at the surface of a membrane. A concentration of 20 ppm of protein could be detected using polymerized thin films. The speed, sensitivity and simplicity of the design offers a new and general approach towards the direct colorimetric detection of a variety of different molecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE STRUCTURE AND FUNCTION OF THE HEMAGGLUTININ MEMBRANE GLYCOPROTEIN OF INFLUENZA VIRUS
Wiley, D. C., & Skehel, J. J. (1987) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.56.070187.002053 · Cited by 1,415
Lipowsky, R. (1991) · Nature · doi:10.1038/349475a0 · Cited by 978
Direct Colorimetric Detection of a Receptor-Ligand Interaction by a Polymerized Bilayer Assembly
Charych, D. H., Nagy, J. O., Spevak, W., & Bednarski, M. D. (1993) · Science · doi:10.1126/science.8342021 · Cited by 733
Self-citationMembrane fusion proteins of enveloped animal viruses
White, J., Kielian, M., & Helenius, A. (1983) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500005072 · Cited by 668
Interaction of Vibrio cholerae enterotoxin with cell membranes
Cuatrecasas, P. (1973) · Biochemistry · doi:10.1021/bi00742a031 · Cited by 523
Kuziemko, G. M., Stroh, M., & Stevens, R. C. (1996) · Biochemistry · doi:10.1021/bi952314i · Cited by 335
Self-citationReichert, A., Nagy, J. O., Spevak, W., & Charych, D. (1995) · Journal of the American Chemical Society · doi:10.1021/ja00107a032 · Cited by 279
Self-citationVirology : a practical approach
Mahy, B. W. J. (1985) · IRL eBooks · Cited by 273
Berman, A., Ahn, D. J., Lio, A., Salmeron, M., Reichert, A., & Charych, D. (1995) · Science · doi:10.1126/science.269.5223.515 · Cited by 258
Self-citationSpevak, W. R., Nagy, J. O., Charych, D. H., Schaefer, M. E., Gilbert, J. H., & Bednarski, M. D. (1993) · Journal of the American Chemical Society · doi:10.1021/ja00056a047 · Cited by 211
Self-citationPolymerization of diacetylene carbonic acid monolayers at the gas‐water interface
Day, D., & Ringsdorf, H. (1978) · Journal of Polymer Science: Polymer Letters Edition · doi:10.1002/pol.1978.130160501 · Cited by 201
Insertion of a Coiled-Coil Peptide from Influenza Virus Hemagglutinin into Membranes
Yu, Y. G., King, D., & Shin, Y. (1994) · Science · doi:10.1126/science.7939662 · Cited by 119
Dobrosavljević, V., & Stratt, R. M. (1987) · Physical review. B, Condensed matter · doi:10.1103/physrevb.35.2781 · Cited by 74
Ledeen, R. W. (1983) · Springer eBooks · doi:10.1007/978-1-4684-4367-7_3 · Cited by 7
Cited by
Conjugated Polymer-Based Chemical Sensors
McQuade, D. T., Pullen, A. E., & Swager, T. M. (2000) · Chemical Reviews · doi:10.1021/cr9801014 · Cited by 3,718
Functional Materials in Food Nanotechnology
Weiss, J., Takhistov, P., & McClements, D. J. (2006) · Journal of Food Science · doi:10.1111/j.1750-3841.2006.00195.x · Cited by 1,104
Color and Chromism of Polydiacetylene Vesicles
Okada, S., Peng, S., Spevak, W., & Charych, D. (1998) · Accounts of Chemical Research · doi:10.1021/ar970063v · Cited by 584
Self-citationKrafft, M. P., & Riess, J. G. (2009) · Chemical Reviews · doi:10.1021/cr800260k · Cited by 497
Optical Amplification of Ligand-Receptor Binding Using Liquid Crystals
Gupta, V. K., Skaife, J. J., Dubrovsky, T. B., & Abbott, N. L. (1998) · Science · doi:10.1126/science.279.5359.2077 · Cited by 476
Metadata
- Authors
- Charych, D., Cheng, Q., Reichert, A., Kuziemko, G., Stroh, M., Nagy, J. O., Spevak, W., & Stevens, R. C.
- Venue
- Chemistry & Biology
- Publisher
- Elsevier BV
- Published
- 1996-02
- Volume
- 3
- Issue
- 2
- Pages
- 113-120
- ISSN
- 1074-5521 (ISSN-L)
- OpenAlex
- W2017310606
- Cited by
- 244
- References
- 14
- FWCI
- 10.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.