Designed protein pores as components for biosensors
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
BACKGROUND: There is a pressing need for new sensors that can detect a variety of analytes, ranging from simple ions to complex compounds and even microorganisms. The devices should offer sensitivity, speed, reversibility and selectivity. Given these criteria, protein pores, remodeled so that their transmembrane conductances are modulated by the association of specific analytes, are excellent prospects as components of biosensors. RESULTS: Structure-based design and a separation method that employs targeted chemical modification have been used to obtain a heteromeric form of the bacterial pore-forming protein staphylococcal alpha-hemolysin, in which one of the seven subunits contains a binding site for a divalent metal ion, M(II), which serves as a prototypic analyte. The single-channel current of the heteromer in planar bilayers is modulated by nanomolar Zn(II). Other M(II)s modulate the current and produce characteristic signatures. In addition, heteromers containing more than one mutant subunit exhibit distinct responses to M(II)s Hence, a large collection of responsive pores can be generated through subunit diversity and combinatorial assembly. CONCLUSIONS: Engineered pores have several advantages as potential sensor elements: sensitivity is in the nanomolar range; analyte binding is rapid (diffusion limited in some cases) and reversible; strictly selective binding is not required because single-channel recordings are rich in information; and for a particular analyte, the dissociation rate constant, the extent of channel block and the voltage-dependence of these parameters are distinguishing, while the frequency of partial channel block reflects the analyte concentration. A single sensor element might, therefore, be used to quantitate more than one analyte at once. The approach described here can be generalized for additional analytes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cleavage of Structural Proteins during the Assembly of the Head of Bacteriophage T4
LAEMMLI, U. K. (1970) · Nature · doi:10.1038/227680a0 · Cited by 249,961
MOLSCRIPT: a program to produce both detailed and schematic plots of protein structures
Kraulis, P. J. (1991) · Journal of Applied Crystallography · doi:10.1107/s0021889891004399 · Cited by 14,085
Raster3D Version 2.0. A program for photorealistic molecular graphics
Merritt, E. A., & Murphy, M. E. P. (1994) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444994006396 · Cited by 2,504
Structure of Staphylococcal α-Hemolysin, a Heptameric Transmembrane Pore
Song, L., Hobaugh, M. R., Shustak, C., Cheley, S., Bayley, H., & Gouaux, J. E. (1996) · Science · doi:10.1126/science.274.5294.1859 · Cited by 2,377
Self-citationSupported Membranes: Scientific and Practical Applications
Sackmann, E. (1996) · Science · doi:10.1126/science.271.5245.43 · Cited by 2,151
Formation of Bimolecular Membranes from Lipid Monolayers and a Study of Their Electrical Properties
Montal, M., & Mueller, P. (1972) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.69.12.3561 · Cited by 1,787
A General Method for Site-specific Incorporation of Unnatural Amino Acids into Proteins
Noren, C. J., Anthony-Cahill, S. J., Griffith, M. C., & Schultz, P. G. (1989) · Science · doi:10.1126/science.2649980 · Cited by 1,019
Alpha-toxin of Staphylococcus aureus
Bhakdi, S. C., & Tranum-Jensen, J. (1991) · Microbiological Reviews · doi:10.1128/mmbr.55.4.733-751.1991 · Cited by 885
Direct Colorimetric Detection of a Receptor-Ligand Interaction by a Polymerized Bilayer Assembly
Charych, D. H., Nagy, J. O., Spevak, W., & Bednarski, M. D. (1993) · Science · doi:10.1126/science.8342021 · Cited by 733
The Emerging Technique of Molecular Imprinting and Its Future Impact on Biotechnology
Mosbach, K., & Ramström, O. (1996) · Nature Biotechnology · doi:10.1038/nbt0296-163 · Cited by 723
Array-Based Vapor Sensing Using Chemically Sensitive, Carbon Black−Polymer Resistors
Lonergan, M. C., Severin, E. J., Doleman, B. J., Beaber, S. A., Grubbs, R. H., & Lewis, N. S. (1996) · Chemistry of Materials · doi:10.1021/cm960036j · Cited by 633
A chemical-detecting system based on a cross-reactive optical sensor array
Dickinson, T. A., White, J., Kauer, J. S., & Walt, D. R. (1996) · Nature · doi:10.1038/382697a0 · Cited by 409
Menestrina, G. (1986) · The Journal of Membrane Biology · doi:10.1007/bf01869935 · Cited by 356
A chemically diverse conducting polymer-based "electronic nose".
Freund, M. S., & Lewis, N. S. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.7.2652 · Cited by 344
Kinetics for the Life Sciences: Receptors, Transmitters and Catalysts
Gutfreund, H. (1995) · Cambridge University Press eBooks · doi:10.1017/cbo9780511626203 · Cited by 335
A ‘litmus test’ for molecular recognition using artificial membranes
Charych, D., Cheng, Q., Reichert, A., Kuziemko, G., Stroh, M., Nagy, J. O., Spevak, W., & Stevens, R. C. (1996) · Chemistry & Biology · doi:10.1016/s1074-5521(96)90287-2 · Cited by 244
Eriksson, A. E., Kylsten, P. M., Jones, T. A., & Liljas, A. (1988) · Proteins: Structure, Function, and Bioinformatics · doi:10.1002/prot.340040407 · Cited by 177
Walker, B. W., & Bayley, H. (1995) · Journal of Biological Chemistry · doi:10.1074/jbc.270.39.23065 · Cited by 157
Self-citationValeva, A., Weisser, A., Walker, B., Kehoe, M., Bayley, H., Bhakdi, S., & Palmer, M. (1996) · The EMBO Journal · doi:10.1002/j.1460-2075.1996.tb00536.x · Cited by 133
Self-citationChen, G., Guan, Z., Chen, C.-T., Fu, L., Sundaresan, V., & Arnold, F. H. (1997) · Nature Biotechnology · doi:10.1038/nbt0497-354 · Cited by 127
Enzyme-based fiber optic zinc biosensor
Thompson, R. B., & Jones, E. R. (1993) · Analytical Chemistry · doi:10.1021/ac00054a013 · Cited by 114
A pore-forming protein with a metal-actuated switch
Walker, B. W., Kasianowicz, J. J., Krishnasastry, M. V., & Bayley, H. (1994) · Protein Engineering Design and Selection · doi:10.1093/protein/7.5.655 · Cited by 102
Self-citationA photogenerated pore-forming protein.
Chang, C.-Y., Niblack, B., Walker, B., & Bayley, H. (1995) · Chemistry and Biology · doi:10.1016/1074-5521(95)90220-1 · Cited by 91
Self-citationWalker, B., Krishnasastry, M. V., Zorn, L. J., Kasianowicz, J. J., & Bayley, H. (1992) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)50103-x · Cited by 86
Self-citationStructure-assisted redesign of a protein-zinc-binding site with femtomolar affinity.
Ippolito, J. A., Baird, T., Mcgee, S., Christianson, D. W., & Fierke, C. A. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.11.5017 · Cited by 79
Fisher, R. J., & Fivash, M. J. (1994) · Current Opinion in Biotechnology · doi:10.1016/0958-1669(94)90047-7 · Cited by 74
Construction and evaluation of a metal ion biosensor
Tescione, L. D., & Belfort, G. (1993) · Biotechnology and Bioengineering · doi:10.1002/bit.260420805 · Cited by 73
Identification of a Putative Membrane-Inserted Segment in the .alpha.-Toxin of Staphylococcus aureus
Ward, R. J., Palmer, M., Leonard, K., & Bhakdi, S. (1994) · Biochemistry · doi:10.1021/bi00189a056 · Cited by 48
Schmidt, A., Müller, H. N., & Skerra, A. (1996) · Chemistry & Biology · doi:10.1016/s1074-5521(96)90132-5 · Cited by 27
A Rapid Bioassay for Platelet–Derived Growth Factor β-Receptor Tyrosine Kinase Function
Graminski, G. F., & Lerner, M. R. (1994) · Nature Biotechnology · doi:10.1038/nbt1094-1008 · Cited by 17
Cited by
The potential and challenges of nanopore sequencing
Branton, D., Deamer, D. W., Marziali, A., Bayley, H., Benner, S. A., Butler, T., Di Ventra, M., Garaj, S., Hibbs, A., Huang, X., et al. (2008) · Nature Biotechnology · doi:10.1038/nbt.1495 · Cited by 2,534
Self-citationNanopore analytics: sensing of single molecules
Howorka, S., & Siwy, Z. (2009) · Chemical Society Reviews · doi:10.1039/b813796j · Cited by 1,170
Stochastic sensors inspired by biology
Bayley, H., & Cremer, P. S. (2001) · Nature · doi:10.1038/35093038 · Cited by 1,118
Self-citationSelf-Assembling Organic Nanotubes
Bong, D. T., Clark, T. D., Granja, J. R., & Ghadiri, M. R. (2001) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20010316)40:6<988::aid-anie9880>3.0.co;2-n · Cited by 1,108
Solid supported lipid bilayers: From biophysical studies to sensor design
Castellana, E. T., & Cremer, P. S. (2006) · Surface Science Reports · doi:10.1016/j.surfrep.2006.06.001 · Cited by 1,090
Metadata
- Authors
- Braha, O., Walker, B., Cheley, S., Kasianowicz, J. J., Song, L., Gouaux, J. E., & Bayley, H.
- Venue
- Chemistry & Biology
- Publisher
- Elsevier BV
- Published
- 1997-07
- Volume
- 4
- Issue
- 7
- Pages
- 497-505
- ISSN
- 1074-5521 (ISSN-L)
- OpenAlex
- W4244913051
- Cited by
- 302
- References
- 30
- FWCI
- 10.03
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.