CoChat

The DOI matches its Crossref record; 34 of the 36 references it cites were found in a registry or an index.

Accuracy of IgE antibody laboratory results

Wood, Robert A., Segall, Nathan, Ahlstedt, Staffan, Williams, P Brock · 2007 · Annals of Allergy, Asthma & Immunology

Abstract

Background Studies have demonstrated that the magnitude of sensitization as evidenced by specific IgE (sIgE) levels provides significant information as to whether a sensitized individual is likely to be truly reactive. However, it is not clear that quantitative sIgE results provided by different laboratories using different technologies are comparable.Objective To investigate whether similar results were obtained from Clinical Laboratory Improvement Act-certified laboratories that used 3 common systems for sIgE antibody determination with serum samples and mouse-human IgE chimeric antibodies with known specificity and quantity.Methods Sixty samples for peanut and 20 for soy were submitted for sIgE determination on 3 different systems: ImmunoCAP, Immulite, and Turbo radioallergosorbent test (RAST). Mouse-human chimeric IgE antibodies specific for the major birch allergen Bet v 1 and for the dust mite allergen Der p 2 were also included.Results A qualitative evaluation using a cutoff of 0.35 kUA/L showed some differences in the ability to detect sIgE sensitization, with the Turbo RAST being most variable. However, considerable differences were found with quantitative evaluation, with Immulite overestimating and Turbo RAST underestimating sIgE compared with ImmunoCAP. Similar discrepancies were seen with the mouse-human chimeric IgE antibody samples.Conclusion These findings have potentially serious clinical implications, since each of these systems is widely used. It is therefore important that all laboratories clarify which system they are using. Just because 2 systems present their results in the same units does not mean that the results are necessarily correct or interchangeable.

Overview

Integrity signals

Registry

Crossref · 10.1016/s1081-1206(10)60618-7

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 36 references

Research works printed but not linked: 1

  1. 1995, Practice parameters for allergy diagnostic testing, Ann Allergy Asthma Immunol, 75, 543

Cited by

See all 120

Metadata

Authors
Wood, R. A., Segall, N., Ahlstedt, S., & Williams, P. B.
Affiliations
  • Johns Hopkins University (US)
  • Karolinska Institutet (SE)
  • University of Missouri–Kansas City (US)
Corresponding author
Wood, Robert A.
Venue
Annals of Allergy, Asthma & Immunology
Publisher
Elsevier BV
Published
2007-07
Volume
99
Issue
1
Pages
34-41
ISSN
1081-1206 (ISSN-L)
OpenAlex
W2085510072
Cited by
120
References
36
Citations by year
2026: 3 · 2025: 3 · 2024: 2 · 2023: 8 · 2022: 3 · 2021: 3 · 2020: 6 · 2019: 5 · 2018: 9 · 2017: 14 · 2016: 8 · 2015: 10 · 2014: 3 · 2013: 4 · 2012: 2
FWCI
6.24
Type
journal article
Language
en
Open access
closed
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Locations
  • Annals of Allergy Asthma & Immunology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Immunology and Allergy › Food Allergy and Anaphylaxis Research
  • Health Sciences › Medicine › Immunology and Allergy › Allergic Rhinitis and Sensitization
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
Keywords
specific IgE, allergen sensitization, ImmunoCAP, Immulite, radioallergosorbent test, Bet v 1, Der p 2, peanut allergy, soy allergy, allergen testing
MeSH terms
Allergens, Animals, Food Hypersensitivity, Humans, Hypersensitivity, Immunoglobulin E, Arachis, Recombinant Fusion Proteins, Sensitivity and Specificity, Serologic Tests, Glycine max, Reproducibility of Results, Antigens, Dermatophagoides, Mice, Antigens, Plant, Arthropod Proteins

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of IgE antibody laboratory results. https://app.cochat.ai/papers/10.1016/s1081-1206(10)60618-7
The paper
Wood, R. A., Segall, N., Ahlstedt, S., & Williams, P. B. (2007). Accuracy of IgE antibody laboratory results. Annals of Allergy, Asthma & Immunology. https://doi.org/10.1016/s1081-1206(10)60618-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.