Accuracy of IgE antibody laboratory results
The DOI matches its Crossref record; 34 of the 36 references it cites were found in a registry or an index.
Abstract
Background Studies have demonstrated that the magnitude of sensitization as evidenced by specific IgE (sIgE) levels provides significant information as to whether a sensitized individual is likely to be truly reactive. However, it is not clear that quantitative sIgE results provided by different laboratories using different technologies are comparable.Objective To investigate whether similar results were obtained from Clinical Laboratory Improvement Act-certified laboratories that used 3 common systems for sIgE antibody determination with serum samples and mouse-human IgE chimeric antibodies with known specificity and quantity.Methods Sixty samples for peanut and 20 for soy were submitted for sIgE determination on 3 different systems: ImmunoCAP, Immulite, and Turbo radioallergosorbent test (RAST). Mouse-human chimeric IgE antibodies specific for the major birch allergen Bet v 1 and for the dust mite allergen Der p 2 were also included.Results A qualitative evaluation using a cutoff of 0.35 kUA/L showed some differences in the ability to detect sIgE sensitization, with the Turbo RAST being most variable. However, considerable differences were found with quantitative evaluation, with Immulite overestimating and Turbo RAST underestimating sIgE compared with ImmunoCAP. Similar discrepancies were seen with the mouse-human chimeric IgE antibody samples.Conclusion These findings have potentially serious clinical implications, since each of these systems is widely used. It is therefore important that all laboratories clarify which system they are using. Just because 2 systems present their results in the same units does not mean that the results are necessarily correct or interchangeable.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, several reports have demonstrated poor agreement in results from testing the same sera by different commercially available assay systems.916,917”
From International Consensus Statement on Allergy and Rhinology: Allergic Rhinitis (2018) · cites this paper as [916]
Citations
Cites
Utility of food-specific IgE concentrations in predicting symptomatic food allergy
Sampson, H. A. (2001) · Journal of Allergy and Clinical Immunology · doi:10.1067/mai.2001.114708 · Cited by 1,362
Sampson, H. A., & Ho, D. G. (1997) · Journal of Allergy and Clinical Immunology · doi:10.1016/s0091-6749(97)70133-7 · Cited by 1,055
Celik‐Bilgili, S., Mehl, A., Verstege, A., Staden, U., Nocon, M., Beyer, K., & Niggemann, B. (2005) · Clinical & Experimental Allergy · doi:10.1111/j.1365-2222.2005.02150.x · Cited by 378
García-Ara, C., Boyano-Martínez, T., Díaz-Pena, J. M., Martín-Muñoz, F., Reche-Frutos, M., & Martín-Esteban, M. (2001) · Journal of Allergy and Clinical Immunology · doi:10.1067/mai.2001.111592 · Cited by 345
Food Allergy: Adverse Reactions to Foods and Food Additives
Gundling, K. (2009) · JAMA · doi:10.1001/jama.2009.63 · Cited by 317
The natural history of tree nut allergy
Fleischer, D. M., Conover-Walker, M. K., Matsui, E. C., & Wood, R. A. (2005) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2005.09.002 · Cited by 304
Self-citationDiagnosing peanut allergy with skin prick and specific IgE testing
Roberts, G., Lack, G., & Pa, T. A. L. S. O. (2005) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2005.02.038 · Cited by 293
Validity of specific IgE antibodies in children with egg allergy
Boyano Martínez, T., García‐Ara, C., DÍaz‐Pena, J. M., Muñoz, F. M., García Sánchez, G., & Esteban, M. M. (2001) · Clinical & Experimental Allergy · doi:10.1046/j.1365-2222.2001.01175.x · Cited by 268
Food Allergy: Adverse Reactions to Foods and Food Additives
(2013) · Wiley eBooks · doi:10.1002/9781118744185 · Cited by 248
Bernstein, I. L., & Ww, S. (1995) · PubMed · Cited by 245
Research works printed but not linked: 1
- 1995, Practice parameters for allergy diagnostic testing, Ann Allergy Asthma Immunol, 75, 543
Cited by
EAACI Molecular Allergology User's Guide
Matricardi, P. M., Kleine‐Tebbe, J., Hoffmann, H. J., Valenta, R., Hilger, C., Hofmaier, S., Aalberse, R. C., Agache, I., Asero, R., Ballmer‐Weber, B., et al. (2016) · Pediatric Allergy and Immunology · doi:10.1111/pai.12563 · Cited by 932
International Consensus Statement on Allergy and Rhinology: Allergic Rhinitis
Wise, S. K., Lin, S. Y., Toskala, E., Orlandi, R. R., Akdis, C. A., Alt, J. A., Azar, A., Baroody, F. M., Bachert, C., Canonica, G. W., et al. (2018) · International Forum of Allergy & Rhinology · doi:10.1002/alr.22073 · Cited by 557
International consensus statement on allergy and rhinology: Allergic rhinitis – 2023
Wise, S. K., Damask, C., Roland, L. T., Ebert, C., Levy, J. M., Lin, S., Luong, A., Rodriguez, K., Sedaghat, A. R., Toskala, E., et al. (2023) · International Forum of Allergy & Rhinology · doi:10.1002/alr.23090 · Cited by 507
Cox, L., Williams, B., Sicherer, S., Oppenheimer, J., Sher, L., Hamilton, R., & Golden, D. (2008) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)60220-7 · Cited by 210
Atopic Characteristics of Adult Patients With Eosinophilic Esophagitis
Roy–Ghanta, S., Larosa, D. F., & Katzka, D. A. (2008) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2007.12.045 · Cited by 201
Correlation of serum allergy (IgE) tests performed by different assay systems
Wang, J., Godbold, J. H., & Sampson, H. A. (2008) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2007.12.1150 · Cited by 188
Clinical laboratory assessment of immediate-type hypersensitivity
Hamilton, R. G. (2010) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2009.09.055 · Cited by 151
Wang, J., & Sampson, H. A. (2011) · Journal of Clinical Investigation · doi:10.1172/jci45434 · Cited by 142
Prenatal versus postnatal sensitization to environmental allergens in a high-risk birth cohort
Rowe, J., Kusel, M., Holt, B. J., Suriyaarachchi, D., Serralha, M., Hollams, E., Yerkovich, S. T., Subrata, L. S., Ladyman, C., Sadowska, A., et al. (2007) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2007.02.016 · Cited by 125
Self-citationAntibody testing in aspergillosis—quo vadis?
Page, I. D., Richardson, M., & Denning, D. W. (2015) · Medical Mycology · doi:10.1093/mmy/myv020 · Cited by 107
“There is also marked variation between the Siemens and ThermoFisher Scientific assays in tests for peanut-specific IgE [184].”
ResultAdvances in Diagnosing Peanut Allergy
Sicherer, S. H., & Wood, R. A. (2012) · The Journal of Allergy and Clinical Immunology In Practice · doi:10.1016/j.jaip.2012.10.004 · Cited by 107
Self-citationDonohue, K. M., Al-alem, U., Perzanowski, M. S., Chew, G. L., Johnson, A., Divjan, A., Kelvin, E. A., Hoepner, L. A., Perera, F. P., & Miller, R. L. (2008) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2008.08.034 · Cited by 92
Khan, S., & Orenstein, S. R. (2008) · Gastroenterology Clinics of North America · doi:10.1016/j.gtc.2008.02.003 · Cited by 106
Diagnosis of Food Allergy: Epicutaneous Skin Tests, In Vitro Tests, and Oral Food Challenge
Lieberman, P., & Sicherer, S. H. (2010) · Current Allergy and Asthma Reports · doi:10.1007/s11882-010-0149-4 · Cited by 92
“Thus, results may not be comparable between tests or between commercial laboratories [30, 31].”
ResultHuman IgE antibody serology: A primer for the practicing North American allergist/immunologist
Hamilton, R. G., & Williams, P. B. (2010) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2010.03.014 · Cited by 83
Self-citationComponent resolved diagnostics for hymenoptera venom allergy
Jakob, T., Müller, U., Helbling, A., & Spillner, E. (2017) · Current Opinion in Allergy & Clinical Immunology · doi:10.1097/aci.0000000000000390 · Cited by 76
Jakob, T., Rafei-Shamsabadi, D. A., Spillner, E., & Müller, S. (2017) · Allergo Journal International · doi:10.1007/s40629-017-0014-2 · Cited by 86
“of sIgE to a given allergen approximately 3–5 fold [52, 53].”
BackgroundResultProficiency Survey-Based Evaluation of Clinical Total and Allergen-Specific IgE Assay Performance
Hamilton, R. G. (2010) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2009-0518-oa.1 · Cited by 69
Popescu, F.-D., & Vieru, M. (2018) · World Journal of Methodology · doi:10.5662/wjm.v8.i3.17 · Cited by 67
Park, K. H., Lee, J., Sim, D. W., & Lee, S. C. (2018) · Annals of Laboratory Medicine · doi:10.3343/alm.2018.38.1.23 · Cited by 62
“Moreover, the results from the two assays are not interchangeable, although they both present reports in kU/L [23].”
BackgroundBarton, R., Hobson, R. P., Denton, M., Peckham, D. G., Brownlee, K. G., Conway, S., & Kerr, M. A. (2008) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2008.06.018 · Cited by 60
“For comparison, with IgE measurements on the ImmunoCAP, 1 kUA equates to 2.42 μ g( Wood et al., 2007 ).”
MethodInfluentialBlank, S., Bilò, M. B., & Ollert, M. (2018) · Clinical & Experimental Allergy · doi:10.1111/cea.13090 · Cited by 52
Advances in IgE Testing for Diagnosis of Allergic Disease
Hamilton, R. G., Hemmer, W., Nopp, A., & Kleine-Tebbe, J. (2020) · The Journal of Allergy and Clinical Immunology: In Practice · doi:10.1016/j.jaip.2020.07.021 · Cited by 52
Testing for Food Reactions: The Good, the Bad, and the Ugly
Mullin, G. E., Swift, K. M., Lipski, L., Turnbull, L. K., & Rampertab, S. D. (2010) · Nutrition in Clinical Practice · doi:10.1177/0884533610362696 · Cited by 59
“Unfortunately, recent publications have confirmed that the results of one method are not generally comparable with those of another.(8,9) Thus, clinicians ordering these tests should be aware of the assay their laboratory is using.”
ResultComparison of molecular and extract-based allergy diagnostics with multiplex and singleplex analysis
Huss-Marp, J., Gutermuth, J., Schäffner, I., Darsow, U., Pfab, F., Brockow, K., Ring, J., Behrendt, H., Jakob, T., & Ahlgrim, C. (2015) · Allergo Journal International · doi:10.1007/s40629-015-0046-4 · Cited by 49
“is approach is complicated due to the fact that IgE results cannot easily be compared between di erent assay manufacturers [2, 3] and across di erent analytical platforms.”
ResultOverview of Serological-Specific IgE Antibody Testing in Children
Cox, L. (2011) · Current Allergy and Asthma Reports · doi:10.1007/s11882-011-0226-3 · Cited by 46
Recommendations for the allergy management in the primary care
Jutel, M., Papadopoulos, N. G., Grönlund, H., Hoffman, H.-J., Bohle, B., Hellings, P. W., Braunsthal, G. ‐., Muraro, A. M., Schmid‐Grendelmeier, P., Zuberbier, T., et al. (2014) · Allergy · doi:10.1111/all.12382 · Cited by 50
“Several studies (22, 23, 24) comparing accuracy, correlation and precision of IgE tests indicate that there is variability in assessed IgE levels.”
BackgroundAntigen 5 Allergens of Hymenoptera Venoms and Their Role in Diagnosis and Therapy of Venom Allergy
Blank, S., Bazon, M. L., Grosch, J., Schmidt‐Weber, C. B., Brochetto-Braga, M. R., Bilò, M. B., & Jakob, T. (2020) · Current Allergy and Asthma Reports · doi:10.1007/s11882-020-00954-0 · Cited by 44
Custovic, A., Soderstrom, L., Ahlstedt, S., Sly, P. D., Simpson, A., & Holt, P. G. (2011) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2011.03.014 · Cited by 44
“The assay technique we used has been shown to accurately quantify IgE antibodies to a variety of allergens, including cat, in a superior manner compared with other IgE antibody methods.(27,28) The IgE antibody determinations with ImmunoCAP have also been shown to be better correlated with clinical disease than for oth…”
Self-citationLatex Sensitization: A Special Risk for the Obstetric Population?
Draisci, G., Zanfini, B. A., Nucera, E., Catarci, S., Sangregorio, R., Schiavino, D., Mannocci, A., & Patriarca, G. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318206ff50 · Cited by 44
“35 kilounits/l was considered normal.(13) Patients experiencing allergic reactions during surgery underwent a skin-prick test with a standard latex extract (500 g/ml; ALK Abellò, Madrid, Spain).”
BackgroundGoikoetxea, M. J., Sanz, M. L., García, B. E., Mayorga, C., Longo, N., Gamboa, P. M., Barber, D., Molina, T. C., Toral, A. D. L. C., Mora, L. E., et al. (2013) · PubMed · Cited by 58
Analysis of allergen specific IgE cut points to cat and dog in the Childhood Allergy Study
Linden, C. C., Misiak, R. T., Wegienka, G., Havstad, S. L., Ownby, D. R., Johnson, C. C., & Zoratti, E. M. (2011) · Annals of Allergy Asthma & Immunology · doi:10.1016/j.anai.2010.11.004 · Cited by 44
Studying specific IgE: in vivo or in vitro
Chong‐Neto, H. J., & Rosário, N. A. (2009) · Allergologia et Immunopathologia · doi:10.1016/s0301-0546(09)70249-6 · Cited by 41
How do we know when peanut and tree nut allergy have resolved, and how do we keep it resolved?
Byrne, A. M., Malka-Rais, J., Burks, A. W., & Fleischer, D. M. (2010) · Clinical & Experimental Allergy · doi:10.1111/j.1365-2222.2010.03554.x · Cited by 41
Divaret‐Chauveau, A., Dalphin, M. L., Mauny, F., Kaulek, V., Schmaußer‐Hechfellner, E., Renz, H. E., Riedler, J., Pekkanen, J., Karvonen, A. M., Lauener, R. P., et al. (2017) · Allergy · doi:10.1111/all.13148 · Cited by 46
“Regarding the method chosen for sIgE, Wood et al.(18) showed some differences in sIgE results according to the method of assay.”
MethodExtension of food allergen specific IgE ranges from the ImmunoCAP to the IMMULITE systems
Hamilton, R. G., Mudd, K., White, M. A., & Wood, R. A. (2011) · Annals of Allergy Asthma & Immunology · doi:10.1016/j.anai.2011.04.012 · Cited by 36
Self-citationHardy, J. I., Hendricks, A., Loeffler, A., Chang, Y., Verheyen, K. L. P., Garden, O. A., & Bond, R. (2014) · Veterinary Dermatology · doi:10.1111/vde.12137 · Cited by 38
Blank, S., Haemmerle, S., Jaeger, T., Rußkamp, D., Ring, J., Schmidt‐Weber, C. B., & Ollert, M. W. (2019) · Allergo Journal International · doi:10.1007/s40629-018-0089-4 · Cited by 32
Bronchial allergen challenges in children – safety and predictors
Schulze, J., Reinmüller, W., Herrmann, E. M., Rosewich, M., Rose, M. A., & Zielen, S. (2013) · Pediatric Allergy and Immunology · doi:10.1111/pai.12031 · Cited by 32
“We used the Immulite test to determine specific IgE; it has been demonstrated in the literature that for samples with more than 10 kU/l of specific IgE, the Immulite results tend to be higher than those measured by ImmunoCAP (22).”
BackgroundResultDiagnostic evaluation of food-related allergic diseases
Eckman, J. A., Saini, S. S., & Hamilton, R. G. (2009) · Allergy Asthma and Clinical Immunology · doi:10.1186/1710-1492-5-2 · Cited by 35
“Recent studies have shown that the Immulite (Siemens Healthcare Diagnostics, Los Angeles, CA, USA) may overestimate specific IgE measurements in comparison to ImmunoCAP results [20,21].”
ResultFuruya, K., Nagao, M., Sato, Y., Ito, S., Fujisawa, T., & IPAD3g investigators (2016) · Allergy · doi:10.1111/all.12912 · Cited by 31
Baur, X., Akdiş, C. A., Budnik, L. T., Cruz, M. J., Fischer, A., Förster‐Ruhrmann, U., Göen, T., Göksel, Ö., Heutelbeck, A. R. R., Jones, M. C., et al. (2019) · Allergy · doi:10.1111/all.13809 · Cited by 32
Quality management in IgE-based allergy diagnostics
Kleine‐Tebbe, J., Poulsen, L. K., & Hamilton, R. G. (2016) · Journal of Laboratory Medicine · doi:10.1515/labmed-2016-0013 · Cited by 27
Yang, J., Lee, H., Choi, A., Park, K. H., Ryu, J. H., & Oh, E. (2018) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2018.1528506 · Cited by 28
“For quantitative sIgE comparison, previous studies have reported variable conclusions [2,11,29].”
BackgroundResultTan, Y., Halsey, J. F., Tang, T., Wetering, S. V., Taine, E., Cleve, M. V., & Cunningham, B. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.071 · Cited by 29
In Vitro Diagnostic Methods in the Evaluation of Food Hypersensitivity
Hamilton, R. (2013) · Wiley eBooks · doi:10.1002/9781118744185.ch8 · Cited by 26
Oral Allergy Syndrome in a Child Provoked by Royal Jelly
Fantini, P., Donne, P. D., Calogiuri, G., Antonio, F., Angelo, V., Nettis, E., & Elisabetta, D. L. (2014) · Case Reports in Medicine · doi:10.1155/2014/941248 · Cited by 25
Zeng, G., Hu, H., Zheng, P., Wu, G., Wei, N., Liang, X., Sun, B., & Zhang, X. (2018) · Annals of Translational Medicine · doi:10.21037/atm.2018.04.06 · Cited by 24
“Along with advances in biomedical sciences, the mainstream techniques for diagnosis of allergy have always been evolving, from the skin scratch test described by Blackley in 1873 (1), the enzyme-linked immunosorbent assay (ELISA) first published by Engvail and Perlmann in 1971 (2), radiation allergen sorbent test (RAS…”
MethodSato, S., Ogura, K., Takahashi, K., Sato, Y., Yanagida, N., & Ebisawa, M. (2016) · Allergology International · doi:10.1016/j.alit.2016.06.012 · Cited by 25
Six years of INSTAND e. V. sIgE proficiency testing: An evaluation of in vitro allergy diagnostics
Wojtalewicz, N., Goseberg, S., Kabrodt, K., & Schellenberg, I. (2017) · Allergo Journal International · doi:10.1007/s40629-016-0005-8 · Cited by 23
Agreement of specific IgE and skin prick test in an unselected cohort of two-year-old children
Rø, A. D. B., Saunes, M., Smidesang, I., Storrø, O., Øien, T., Moen, T., & Johnsen, R. (2011) · European Journal of Pediatrics · doi:10.1007/s00431-011-1580-9 · Cited by 22
“Significant differences are shown among different sIgE immunoassays [19, 26, 28].”
BackgroundClinical History–Driven Diagnosis of Allergic Diseases: Utilizing in vitro IgE Testing
Adkinson, N. F., & Hamilton, R. G. (2015) · The Journal of Allergy and Clinical Immunology In Practice · doi:10.1016/j.jaip.2015.08.002 · Cited by 22
Wongpiyabovorn, J., Suratannon, N., Boonmee, S., & Chatchatee, P. (2017) · Asian Pacific Journal of Allergy and Immunology · doi:10.12932/ap-270217-0035 · Cited by 25
Lee, S. E., Ahn, K., Paik, H. Y., & Chung, S. (2012) · Nutrition Research and Practice · doi:10.4162/nrp.2012.6.5.429 · Cited by 18
“35 kUA/l (RAST class ≥ 1) by CAP assay were considered positive [33].”
MethodDisagreement between Skin Prick Tests and Specific IgE in Early Childhood
Divaret‐Chauveau, A., Dalphin, M., Kaulek, V., Roduit, C., Pugin, A., von Mutius, E., Vuitton, D. A., & Dalphin, J. (2016) · International Archives of Allergy and Immunology · doi:10.1159/000446776 · Cited by 21
Role of specific I g E in predicting the clinical course of lentil allergy in children
Yavuz, S. T., Şahiner, Ü. M., Büyüktiryaki, B., Tuncer, A., Yılmaz, E. A., Cavkaytar, Ö., Karabulut, E., & Saçkesen, C. (2013) · Pediatric Allergy and Immunology · doi:10.1111/pai.12080 · Cited by 18
Assessment of human allergic diseases
Hamilton, R. (2008) · Elsevier eBooks · doi:10.1016/b978-0-323-04404-2.10100-9 · Cited by 18
Lokas, S. B., Plavec, D., Rikić, J., Živković, J., Nogalo, B., & Turkalj, M. (2016) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.22047 · Cited by 19
Food anaphylaxis diagnostic marker compilation in machine learning design and validation
Randhawa, I., Groshenkov, K., & Sigalov, G. M. (2023) · PLoS ONE · doi:10.1371/journal.pone.0283141 · Cited by 16
Smoldovskaya, O., Feyzkhanova, G., Arefieva, A., Voloshin, S., Ivashkina, O. A., Reznikov, Y., & Rubina, A. Y. (2016) · Allergy Asthma and Clinical Immunology · doi:10.1186/s13223-016-0117-1 · Cited by 18
“considerably in composition and activity [2, 3], leading to discrepancy between analysis results in various test systems [4].”
BackgroundHawi, Y. A., Nagao, M., Furuya, K., Sato, Y., Ito, S., Hori, H., Hirayama, M., Fujisawa, T., & on behalf of IPAD3g investigators (2020) · Allergy Asthma and Immunology Research · doi:10.4168/aair.2021.13.1.141 · Cited by 16
Ben‐Shoshan, M., Kagan, R., Primeau, M.-N., Alizadehfar, R., Turnbull, E., Harada, L., Dufresne, C., Allen, M., Joseph, L., Pierre, Y. S., et al. (2010) · Pediatric Allergy and Immunology · doi:10.1111/j.1399-3038.2010.00994.x · Cited by 19
Guidelines on the clinical usefulness of determination of specific immunoglobulin E to foods.
García, B. E., Gamboa, P. M., Asturias, J. A., López‐Hoyos, M., Ml, S., Caballero, M. T., García, J. B., Labrador‐Horrillo, M., Lahoz, C., Areso, N. L., et al. (2009) · PubMed · Cited by 14
The RIDA Allergy Screen Versus the Phadiatop Test in 430 Consecutive Patient Specimens
Hwang, H., Kwon, J., Kim, J. Y., Lee, H. H., Oh, C. E., & Choi, G. (2016) · Laboratory Medicine · doi:10.1093/labmed/lmv002 · Cited by 13
Allergen cross reactions: a problem greater than ever thought?
Pfiffner, P. B., Truffer, R., Matsson, P., Rasi, C., Mari, A., & Stadler, B. M. (2010) · Allergy · doi:10.1111/j.1398-9995.2010.02420.x · Cited by 13
“Because it has been shown that ImmunoCAP sIgE determinations are accurate on a mass unit level (17), IgE levels of different extracts can be compared.”
BackgroundNeilan, N. A., Dowling, P. J., Taylor, D. L., Ryan, P., Schurman, J. V., & Friesen, C. A. (2010) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1097/mpg.0b013e3181c2c28a · Cited by 11
“Clinically significant differences were found when comparing quantitative SIgE results generated by the 3 most commonly used Food and Drug Administration–approved platforms (59).”
MethodWojtalewicz, N., Kabrodt, K., Goseberg, S., & Schellenberg, I. (2018) · Annals of Allergy Asthma & Immunology · doi:10.1016/j.anai.2018.07.016 · Cited by 11
Casas, M. L. M. D. L., Esteban, Á., González‐Muñoz, M., Labrador‐Horrillo, M., Pascal, M., & Teniente‐Serra, A. (2020) · Advances in Laboratory Medicine / Avances en Medicina de Laboratorio · doi:10.1515/almed-2020-0051 · Cited by 14
Human Allergen-Specific IgG Subclass Antibodies Measured Using ImmunoCAP Technology
Movérare, R., Blume, K., Lind, P., Crevel, R., DeWitt, Å. M., & Cochrane, S. (2017) · International Archives of Allergy and Immunology · doi:10.1159/000455098 · Cited by 9
PIACENTINI, G. L., Guerresi, S., Kantar, A., Lubrano, L., Olivieri, F., Boner, A. L., & Peroni, D. G. (2011) · International Journal of Immunopathology and Pharmacology · doi:10.1177/039463201102400422 · Cited by 9
Correlations Between Allergen-Specific IgE Serum Levels in Patients With Ocular Allergy
Polido, J. G. F., Cabral, T., Perini, P. D. R. C., Fernandes, M. D. F. M., de Freitas, D., Araújo, M. E. X. D. S., & Serracarbassa, P. D. (2015) · Cornea · doi:10.1097/ico.0000000000000496 · Cited by 9
“Similar to this study, some previous reports have indicated that the Immulite system overestimates and the Turbo RAST system underestimates the IgE levels compared with ImmunoCAP.(20) Villalta et al demonstrated high diagnostic accuracy of the sIgE levels to allergen components measured with Immulite 2000 and high agr…”
ResultInfluentialJakob, T., & Spillner, E. (2017) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2016.09.058 · Cited by 9
Indian Guidelines for Diagnosis of Respiratory Allergy
Kumar, R., Behera, D., Singh, A. B., Gaur, S., Agarwal, M. K., Prasad, R., Menon, B., Goel, N., Mrigpuri, P., Spalgais, S., et al. (2023) · Indian Journal of Allergy Asthma and Immunology · doi:10.4103/0972-6691.367373 · Cited by 11
Allergen-Based Diagnostic: Novel and Old Methodologies with New Approaches
Salazar, A., Velázquez-Soto, H., Ayala-Balboa, J., & Martínez, M. D. C. J. (2017) · InTech eBooks · doi:10.5772/intechopen.69276 · Cited by 14
Generating allergen-specific human IgEs for immunoassays by employing human ε gene knockin mice
Lu, C., Hung, A. F.-H., Lin, C.-J., Chen, J.-B., Chen, C., Shiung, Y.-Y., Tsai, C., & Chang, T. W. (2015) · Allergy · doi:10.1111/all.12572 · Cited by 9
ACCURACY OF IgE ANTIBODY LABORATORY RESULTS
Hovanec-Burns, D. (2008) · Annals of Allergy Asthma & Immunology · doi:10.1016/s1081-1206(10)60435-8 · Cited by 8
Fundamentals of laboratory diagnostics in allergology
Arsenis, C., Τaka, S., & Skevaki, C. L. (2025) · Allergo Journal International · doi:10.1007/s40629-025-00323-1 · Cited by 7
Rational Approach to Allergy Testing
Platt, M. P., & Wulu, J. A. (2017) · Otolaryngologic Clinics of North America · doi:10.1016/j.otc.2017.08.007 · Cited by 8
Jakob, T., Rafei-Shamsabadi, D. A., Spillner, E., & Müller, S. (2017) · Allergo Journal · doi:10.1007/s15007-017-1315-y · Cited by 7
Casas, M. L. M. D. L., Esteban, Á., González‐Muñoz, M., Labrador‐Horrillo, M., Pascal, M., & Teniente‐Serra, A. (2020) · Advances in Laboratory Medicine / Avances en Medicina de Laboratorio · doi:10.1515/almed-2020-0022 · Cited by 7
Extract-Shaped Immune Repertoires as Source for Nanobody-Based Human IgE in Grass Pollen Allergy
Aagaard, J. B., Fischer, M., Lober, J., Neumann, F. B., Allahverdi, D., Sivelle, C., Miehe, M., & Spillner, E. (2023) · Molecular Biotechnology · doi:10.1007/s12033-023-00664-8 · Cited by 6
“by using single monoclonal IgE or animal serum complexed with IgE adapters [22, 34, 35].”
MethodMolecular engineering of nanobodies as tools in allergology: diagnostics and beyond
Aagaard, J. B., Ballegaard, A. R., Ommen, P., & Spillner, E. (2023) · Allergo Journal International · doi:10.1007/s40629-023-00261-w · Cited by 6
Hammerberg, B. (2009) · Veterinary Immunology and Immunopathology · doi:10.1016/j.vetimm.2009.09.009 · Cited by 7
Ito, K., & Tagami, K. (2021) · Clinical and Molecular Allergy · doi:10.1186/s12948-021-00151-y · Cited by 5
“Since a close agreement of total IgE concentrations measured with the IMMULITE and ImmunoCAP systems has earlier been demonstrated [21] and both are calibrated against the current WHO reference preparation of IgE, substantially divergent specific and total IgE results can only be attributed to the specific IgE assays.”
BackgroundLuo, W., Pan, G., Huang, H., Zheng, P., Wei, N., Zhang, Y., Zeng, G., & Sun, B. (2017) · Journal of Visualized Experiments · doi:10.3791/55723 · Cited by 5
The impact of comorbidities on the severity of atopic dermatitis in children
Berce, V., Marhold, T., & Delopst, V. (2021) · Advances in Dermatology and Allergology · doi:10.5114/ada.2021.108426 · Cited by 5
“35 kU/l was used to confirm allergic sensitisation [18].”
MethodMultiparametric or multiplex systems in allergy diagnostics
Edited by the SIAIP Allergy Diagnostic Commission, Bernardini, R., Arasi, S., Barni, S., Caimmi, D. P., Chiera, F., Dinardo, G., Giannetti, A., Gracci, S., Mastrorilli, C., et al. (2024) · Rivista di immunologia ed allergologia pediatrica. · doi:10.53151/2531-3916/2024-436 · Cited by 4
Peanut Allergy Diagnosis: Current Practices, Emerging Technologies, and Future Directions
Satnarine, T., Makkoukdji, N., Pundit, V., Vignau, A., Sharma, P., Warren, D., Kleiner, G., & Gans, M. D. (2025) · Allergies · doi:10.3390/allergies5010004 · Cited by 6
“Results can vary, however, depending on the laboratory technique used by different laboratories [21].”
Skin Testing versus in Vitro Testing in the Evaluation of Aeroallergy: The Great Debate
Oppenheimer, J. (2015) · American Journal of Rhinology and Allergy · doi:10.2500/ajra.2015.29.4211 · Cited by 4
Third-party verification of total and specific immunoglobulin E on analyzer Immulite® 2000XPi
Vuljanić, D., Dukić, L., Krleža, J. L., Juroš, G. F., Pozaić, P., & Šimundić, A.-M. (2019) · Clinica Chimica Acta · doi:10.1016/j.cca.2019.09.015 · Cited by 4
Laboratory Diagnosis of Human Allergic Disease
Hamilton, R. (2015) · Elsevier eBooks · doi:10.1016/b978-0-323-29875-9.00018-5 · Cited by 3
Heron, M., Schreurs, M. W. J., Haagen, I.-A., China, B., Faria, A. P., Vanhanen, A.-R., Thelen, M., & Weykamp, C. W. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-0862 · Cited by 3
“Especially when using published cut-o ff s, used for clinical decision making, measured with the other assay [7, 9, 13 – 17].”
MethodBlank, S., Haemmerle, S., Jaeger, T., Rußkamp, D., Ring, J., Schmidt‐Weber, C. B., & Ollert, M. W. (2019) · Allergo Journal · doi:10.1007/s15007-019-1916-8 · Cited by 3
“In this study, the Immulite 2000® platform was used which reportedly leads to higher sIgE values compared to the ImmunoCAP® system, due to the di®erent calibration approach that is used [24, 25, 26, 27, 28].”
Quantitation and Standardization of Allergens
Strader, M. B., Zagorski, R., Rabin, R. L., & Slater, J. E. (2024) · Wiley eBooks · doi:10.1002/9781683674023.ch75 · Cited by 3
Vergleich molekularer und extraktbasierter IgE-Diagnostik mittels Multiplex- und Singleplex-Test
Huss‐Marp, J., Gutermuth, J., Schäffner, I., Darsow, U. G., Pfab, F., Brockow, K., Ring, J., Behrendt, H., Jakob, T., & Ahlgrim, C. (2015) · Allergo Journal · doi:10.1007/s15007-015-0784-0 · Cited by 2
Six years of INSTAND e. V. sIgE proficiency testing: an evaluation of in vitro allergy diagnostics
Wojtalewicz, N., Goseberg, S., Kabrodt, K., & Schellenberg, I. (2017) · Allergo Journal · doi:10.1007/s15007-017-1297-9 · Cited by 3
“But the good comparability of the allergen classes can be quite confusing, since they can sometimes mask high dierences within the kU/L results [13].”
BackgroundDiagnostic value of serum total IgE the primary marker of allergic diseases
Mokronosova, M. A. (2015) · Laboratory Service · doi:10.17116/labs20154310-14 · Cited by 2
In vitro methods to assess allergy
Akar-Ghibril, N., & Chang, C. C.-C. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-95061-9.00011-4 · Cited by 2
HYCOR TURBO-MP SPECIFIC IgE ASSAY PERFORMANCE
Kontis, K. J., & Nayak, N. (2008) · Annals of Allergy Asthma & Immunology · doi:10.1016/s1081-1206(10)60432-2 · Cited by 1
Diagnostic tests for human allergic disease
Hamilton, R. G. (2008) · Expert Opinion on Medical Diagnostics · doi:10.1517/17530059.2.10.1123 · Cited by 1
“This is consistent with another recent comparative study [25] and it most probably stems from a different distribution of components in the”
BackgroundMethodResultInfluential
Metadata
- Authors
- Wood, R. A., Segall, N., Ahlstedt, S., & Williams, P. B.
- Affiliations
- Johns Hopkins University (US)
- Karolinska Institutet (SE)
- University of Missouri–Kansas City (US)
- Corresponding author
- Wood, Robert A.
- Venue
- Annals of Allergy, Asthma & Immunology
- Publisher
- Elsevier BV
- Published
- 2007-07
- Volume
- 99
- Issue
- 1
- Pages
- 34-41
- ISSN
- 1081-1206 (ISSN-L)
- OpenAlex
- W2085510072
- Semantic Scholar
- 3da5cf444a9a60db1e6512f3bac8253d91a34815
- Cited by
- 120
- References
- 36
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 2 · 2023: 8 · 2022: 3 · 2021: 3 · 2020: 6 · 2019: 5 · 2018: 9 · 2017: 14 · 2016: 8 · 2015: 10 · 2014: 3 · 2013: 4 · 2012: 2
- FWCI
- 6.24
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Annals of Allergy Asthma & Immunology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Immunology and Allergy › Food Allergy and Anaphylaxis Research
- Health Sciences › Medicine › Immunology and Allergy › Allergic Rhinitis and Sensitization
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Keywords
- specific IgE, allergen sensitization, ImmunoCAP, Immulite, radioallergosorbent test, Bet v 1, Der p 2, peanut allergy, soy allergy, allergen testing
- MeSH terms
- Allergens, Animals, Food Hypersensitivity, Humans, Hypersensitivity, Immunoglobulin E, Arachis, Recombinant Fusion Proteins, Sensitivity and Specificity, Serologic Tests, Glycine max, Reproducibility of Results, Antigens, Dermatophagoides, Mice, Antigens, Plant, Arthropod Proteins
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.