Allergen-Specific IgE Measured by a Continuous Random-Access Immunoanalyzer: Interassay Comparison and Agreement with Skin Testing
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background: Our aims were to evaluate the performance of a fully automated system for measuring circulating allergen-specific IgE (sIgE) against an established in vitro assay and to assess the system’s diagnostic accuracy against objective clinical criteria for identifying sensitization to specific allergens. Methods: Using both the IMMULITE® 2000 Allergy system (IML) and an assay based on the widely used ImmunoCAP® technology (CAP), we measured sIgE in serum samples from 169 persons with suspected allergies to airborne or insect venom allergens. Skin testing outcome served as the clinical comparison method. Results: Interassay classification agreement between the IML and CAP, relative to the usual allergen-specific IgE cutoff of 0.35 kIU/L, ranged from 76% (yellow jacket venom) to 95% (orchard grass); agreement was 88.3% for all 9 allergens combined (766 results). The 90 discordant results, when resolved by skin testing, showed better agreement with the IML (72%) than with the CAP (28%). Compared with skin testing, for each of the 9 allergens studied, the area under the ROC curve was at least as large for the IML as for the CAP, reflecting in part the more extensive working range of the IML (0.10–100 kIU/L vs 0.35–100 kIU/L for CAP). Conclusion: Laboratory testing for sIgE can be performed on a fully automated, random-access system with an extended working range and with diagnostic accuracy for representative allergens equivalent to or better than that of the semiautomated CAP technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Probable Inference, the Law of Succession, and Statistical Inference
Wilson, E. B. (1927) · Journal of the American Statistical Association · doi:10.1080/01621459.1927.10502953 · Cited by 4,476
Johansson, S. G. O., Bieber, T., Dahl, R., Friedmann, P. S., Lanier, B. Q., Lockey, R. F., Motala, C., Ortega Martell, J. A., Platts-Mills, T. A. E., Ring, J., et al. (2004) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2003.12.591 · Cited by 2,391
Self-citationDIAGNOSIS OF ALLERGY BY AN IN-VITRO TEST FOR ALLERGEN ANTIBODIES
Wide, L., Bennich, H., & Johansson, S. G. O. (1967) · The Lancet · doi:10.1016/s0140-6736(67)90615-0 · Cited by 1,253 · cited 1×
“Originally described in 1967 by Wide et al. ( 7 ), the radioallergosorbent test (RAST) became the first routine technique for the determination of sIgE antibodies in serum.”
Background
Cited by
Allergy Diagnostic Testing: An Updated Practice Parameter
Bernstein, I. L., Li, J. T., Bernstein, D. I., Hamilton, R., Spector, S. L., Tan, R., Sicherer, S., Golden, D. B. K., Khan, D. A., Nicklas, R. A., et al. (2008) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)60305-5 · Cited by 723
Accuracy of IgE antibody laboratory results
Wood, R. A., Segall, N., Ahlstedt, S., & Williams, P. B. (2007) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)60618-7 · Cited by 120
Popescu, F.-D., & Vieru, M. (2018) · World Journal of Methodology · doi:10.5662/wjm.v8.i3.17 · Cited by 67
Metadata
- Authors
- Ollert, M., Weissenbacher, S., Rakoski, J., & Ring, J.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-07-01
- Volume
- 51
- Issue
- 7
- Pages
- 1241-1249
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2002000698
- Cited by
- 68
- References
- 3
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Allergen-Specific IgE Measured by a Continuous Random-Access Immunoanalyzer: Interassay Comparison and Agreement with Skin Testing. https://app.cochat.ai/papers/10.1373/clinchem.2004.046565
- The paper
- Ollert, M., Weissenbacher, S., Rakoski, J., & Ring, J. (2005). Allergen-Specific IgE Measured by a Continuous Random-Access Immunoanalyzer: Interassay Comparison and Agreement with Skin Testing. Clinical Chemistry. https://doi.org/10.1373/clinchem.2004.046565
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.