The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Transcutaneous electrical nerve stimulation (TENS) can reduce postoperative analgesic consumption. A meta‐analysis with assessment of optimal treatment parameters for postoperative pain
Abstract
Aim. We investigated the literature of randomised placebo‐controlled trials to find out if transcutaneous electrical nerve stimulation (TENS) or acupuncture‐like transcutaneous electrical nerve stimulation (ALTENS) can reduce analgesic consumption after surgery. Results. Subgroup analysis for adequate treatment (pulse frequency: 1–8 Hz [ALTENS] or 25–150 Hz [TENS], current intensity: “strong, definite, subnoxious, maximal tolerable” or above 15 mA, and electrode placement in the incision area) were performed. Twenty‐one randomised, placebo‐controlled trials with a total of 1350 patients were identified. For all trials, the mean reduction in analgesic consumption after TENS/ALTENS was 26.5% (range −6 to +51%) better than placebo. Eleven of the trials compromising 964 patients, had reports which stated that a strong, subnoxious electrical stimulation with adequate frequency was administered. They reported a mean weighted reduction in analgesic consumption of 35.5% (range 14–51%) better than placebo. In nine trials without explicit confirmation of sufficient current intensity and adequate frequency, the mean weighted analgesic consumption was 4.1% (range −10 to +29%) in favour of active treatment. The difference in analgesic consumption was significantly (p=0.0002) in favour of adequate stimulation. The median frequencies used in trials with optimal treatment was 85 Hz for TENS and 2 Hz in the only trial that investigated ALTENS. Conclusion. TENS, administered with a strong, subnoxious intensity at an adequate frequency in the wound area, can significantly reduce analgesic consumption for postoperative pain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schulz (1995) · doi:10.1001/jama.1995.03520290060030 · Cited by 5,634
McQuay, & Moore (1998) · Health Technology Assessment · doi:10.3310/hta2120 · Cited by 131
Cited by
Chou, R., Gordon, D. B., de Leon-Casasola, O. A., Rosenberg, J. M., Bickler, S., Brennan, T., Carter, T., Cassidy, C. L., Chittenden, E. H., Degenhardt, E., et al. (2016) · The Journal of Pain · doi:10.1016/j.jpain.2015.12.008 · Cited by 3,171
Treatment of acute postoperative pain
Wu, C. L., & Raja, S. N. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60245-6 · Cited by 628
Chow, R. T., Johnson, M. I., Lopes-Martins, R. A., & Bjordal, J. M. (2009) · The Lancet · doi:10.1016/s0140-6736(09)61522-1 · Cited by 613
Self-citationUsing Tens for Pain Control: The State of the Evidence
Vance, C. G., Dailey, D. L., Rakel, B. A., & Sluka, K. A. (2014) · Pain Management · doi:10.2217/pmt.14.13 · Cited by 480
Chapman, C. R., & Vierck, C. J. (2017) · The Journal of Pain · doi:10.1016/j.jpain.2016.11.004 · Cited by 423
Metadata
- Authors
- Bjordal, J. M., Johnson, M. I., & Ljunggreen, A. E.
- Venue
- European Journal of Pain
- Publisher
- Wiley
- Published
- 2003-04
- Volume
- 7
- Issue
- 2
- Pages
- 181-188
- ISSN
- 1090-3801 (ISSN-L)
- 1532-2149
- OpenAlex
- W2138681768
- Cited by
- 380
- References
- 2
- FWCI
- 6.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transcutaneous electrical nerve stimulation (TENS) can reduce postoperative analgesic consumption. A meta‐analysis with assessment of optimal treatment parameters for postoperative pain. https://app.cochat.ai/papers/10.1016/s1090-3801(02)00098-8
- The paper
- Bjordal, J. M., Johnson, M. I., & Ljunggreen, A. E. (2003). Transcutaneous electrical nerve stimulation (TENS) can reduce postoperative analgesic consumption. A meta‐analysis with assessment of optimal treatment parameters for postoperative pain. European Journal of Pain. https://doi.org/10.1016/s1090-3801(02)00098-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.