Transcutaneous electrical nerve stimulation (TENS) can reduce postoperative analgesic consumption. A meta‐analysis with assessment of optimal treatment parameters for postoperative pain
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Aim. We investigated the literature of randomised placebo‐controlled trials to find out if transcutaneous electrical nerve stimulation (TENS) or acupuncture‐like transcutaneous electrical nerve stimulation (ALTENS) can reduce analgesic consumption after surgery. Results. Subgroup analysis for adequate treatment (pulse frequency: 1–8 Hz [ALTENS] or 25–150 Hz [TENS], current intensity: “strong, definite, subnoxious, maximal tolerable” or above 15 mA, and electrode placement in the incision area) were performed. Twenty‐one randomised, placebo‐controlled trials with a total of 1350 patients were identified. For all trials, the mean reduction in analgesic consumption after TENS/ALTENS was 26.5% (range −6 to +51%) better than placebo. Eleven of the trials compromising 964 patients, had reports which stated that a strong, subnoxious electrical stimulation with adequate frequency was administered. They reported a mean weighted reduction in analgesic consumption of 35.5% (range 14–51%) better than placebo. In nine trials without explicit confirmation of sufficient current intensity and adequate frequency, the mean weighted analgesic consumption was 4.1% (range −10 to +29%) in favour of active treatment. The difference in analgesic consumption was significantly (p=0.0002) in favour of adequate stimulation. The median frequencies used in trials with optimal treatment was 85 Hz for TENS and 2 Hz in the only trial that investigated ALTENS. Conclusion. TENS, administered with a strong, subnoxious intensity at an adequate frequency in the wound area, can significantly reduce analgesic consumption for postoperative pain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722
Schulz (1995) · doi:10.1001/jama.1995.03520290060030 · Cited by 5,634 · cited 2×
“While earlier studies suggested that only a positive outcome was exaggerated by poor blinding (Schulz et al., 1995), more recent papers have reported that poor blinding causes the outcome variance in both directions to increase (Verhagen et al., 2000).”
ResultSystematic Reviews: Identifying relevant studies for systematic reviews
Dickersin, K., Scherer, R., & Lefebvre, C. (1994) · BMJ · doi:10.1136/bmj.309.6964.1286 · Cited by 2,256
Moore, A. R., Gavaghan, D., Tramèr, R. M., Collins, L. S., & McQuay, J. H. (1998) · Pain · doi:10.1016/s0304-3959(98)00140-7 · Cited by 604
Thompson, S. G., & Pocock, S. J. (1991) · The Lancet · doi:10.1016/0140-6736(91)91975-z · Cited by 487
Wang, B., Tang, J., White, P. F., Naruse, R., Sloninsky, A., Kariger, R., Gold, J., & Wender, R. H. (1997) · Anesthesia & Analgesia · doi:10.1097/00000539-199708000-00029 · Cited by 216
Carroll, D., Tramèr, M., McQuay, H., Nye, B., & Moore, A. (1996) · British Journal of Anaesthesia · doi:10.1093/bja/77.6.798 · Cited by 213
Deyo, R. A., Walsh, N. E., Schoenfeld, L. S., & Ramamurthy, S. (1990) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-199002000-00003 · Cited by 179
Psychological characteristics and the effectiveness of patient-controlled analgesia
Thomas, V. N., Heath, M. L., ROSE, D., & FLORY, P. (1995) · British Journal of Anaesthesia · doi:10.1093/bja/74.3.271 · Cited by 175
Low Level Laser Therapy for Tendinopathy. Evidence of A Dose–Response Pattern
Bjordal, J. M., Couppé, C., & Ljunggren, A. E. (2001) · Physical Therapy Reviews · doi:10.1179/ptr.2001.6.2.91 · Cited by 174
Self-citation
Cited by
Chou, R., Gordon, D. B., de Leon-Casasola, O. A., Rosenberg, J. M., Bickler, S., Brennan, T., Carter, T., Cassidy, C. L., Chittenden, E. H., Degenhardt, E., et al. (2016) · The Journal of Pain · doi:10.1016/j.jpain.2015.12.008 · Cited by 3,171
Treatment of acute postoperative pain
Wu, C. L., & Raja, S. N. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60245-6 · Cited by 628
Chow, R. T., Johnson, M. I., Lopes-Martins, R. A., & Bjordal, J. M. (2009) · The Lancet · doi:10.1016/s0140-6736(09)61522-1 · Cited by 613
Self-citationUsing Tens for Pain Control: The State of the Evidence
Vance, C. G., Dailey, D. L., Rakel, B. A., & Sluka, K. A. (2014) · Pain Management · doi:10.2217/pmt.14.13 · Cited by 480
Chapman, C. R., & Vierck, C. J. (2017) · The Journal of Pain · doi:10.1016/j.jpain.2016.11.004 · Cited by 423
Bjordal, J. M., Johnson, M. I., Lopes-Martins, R. A., Bogen, B., Chow, R., & Ljunggren, A. E. (2007) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-8-51 · Cited by 329
Self-citationMultimodal therapies for postoperative nausea and vomiting, and pain
Chandrakantan, A., & Glass, P. S. A. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer358 · Cited by 307
Clinical Practice Guidelines for Pain Management in Acute Musculoskeletal Injury
Hsu, J. R., Mir, H., Wally, M. K., Seymour, R. B., & the Orthopaedic Trauma Association Musculoskeletal Pain Task Force (2019) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0000000000001430 · Cited by 280
Transcutaneous Electrical Nerve Stimulation: Mechanisms, Clinical Application and Evidence
Johnson, M. (2007) · Reviews in Pain · doi:10.1177/204946370700100103 · Cited by 272
Self-citationJohnson, M., & Martinson, M. (2007) · Pain · doi:10.1016/j.pain.2007.02.007 · Cited by 269
Self-citationTranscutaneous electrical nerve stimulation for acute pain
Walsh, D. M., Howe, T. E., Johnson, M. I., Moran, F., & Sluka, K. A. (2009) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006142.pub2 · Cited by 247
Self-citationTranscutaneous electrical nerve stimulation (TENS) for neuropathic pain in adults
Gibson, W., Wand, B. M., & O'Connell, N. E. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011976.pub2 · Cited by 247
Dailey, D. L., Rakel, B. A., Vance, C. G. T., Liebano, R. E., Amrit, A. S., Bush, H. M., Lee, K. S., Lee, J. E., & Sluka, K. A. (2013) · Pain · doi:10.1016/j.pain.2013.07.043 · Cited by 241
“We, and others, have previously shown that TENS applied at inadequate intensities does not reduce pain or increase pressure pain thresholds (PPTs) [4,48,49].”
BackgroundTranscutaneous electrical nerve stimulation for acute pain
Johnson, M. I., Paley, C. A., Howe, T. E., & Sluka, K. A. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006142.pub3 · Cited by 240
Self-citationGibson, W., Wand, B. M., Meads, C., Catley, M. J., & O'Connell, N. E. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011890.pub3 · Cited by 231
“…to be a critical factor in optimising TENS eGicacy and it is thought that, regardless of frequency of application, the intensity needs to produce a strong, non-painful sensation which ideally is titrated during treatment to maintain the intensity level (Bjordal 2003; Moran 2011; Sluka 2013).”
BackgroundSluka, K. A., Bjordal, J. M., Marchand, S., & Rakel, B. A. (2013) · Physical Therapy · doi:10.2522/ptj.20120281 · Cited by 204
Self-citationMoran, F., Leonard, T., Hawthorne, S., Hughes, C. M., McCrum-Gardner, E., Johnson, M. I., Rakel, B. A., Sluka, K. A., & Walsh, D. M. (2011) · The Journal of Pain · doi:10.1016/j.jpain.2011.02.352 · Cited by 201
Self-citationTranscutaneous electric nerve stimulation (TENS) for cancer pain in adults
Hurlow, A., Bennett, M. I., Robb, K. A., Johnson, M. I., Simpson, K. H., & Oxberry, S. G. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006276.pub3 · Cited by 199
Self-citationTedesco, D., Gori, D., Desai, K. R., Asch, S., Carroll, I. R., Curtin, C., McDonald, K. M., Fantini, M. P., & Hernandez-Boussard, T. (2017) · JAMA Surgery · doi:10.1001/jamasurg.2017.2872 · Cited by 195
White, A., Cummings, M., Barlas, P., Cardini, F., Filshie, J., Foster, N. E., Lundeberg, T., Stener-Victorin, E., & Witt, C. (2008) · Acupuncture in Medicine · doi:10.1136/aim.26.2.111 · Cited by 195
Pyati, S., & Gan, T. J. (2007) · CNS Drugs · doi:10.2165/00023210-200721030-00002 · Cited by 180
“This study suggests that music therapy has a shortPrevious systematic reviews[49,222] on TENS and term benefit in reducing pain and anxiety, decreaspostoperative pain showed several inconsistencies ing the pain perception through cognitive copin the effectiveness of TENS.”
BackgroundMethodVance, C. G. T., Rakel, B. A., Blodgett, N. P., DeSantana, J. M., Amendola, A., Zimmerman, M. B., Walsh, D. M., & Sluka, K. A. (2012) · Physical Therapy · doi:10.2522/ptj.20110183 · Cited by 178
Rakel, B. A., Zimmerman, B. M., Geasland, K., Embree, J., Clark, C. R., Noiseux, N. O., Callaghan, J. J., Herr, K., Walsh, D., & Sluka, K. A. (2014) · Pain · doi:10.1016/j.pain.2014.09.025 · Cited by 115
Touch inhibits subcortical and cortical nociceptive responses
Mancini, F., Beaumont, A.-L., Hu, L., Haggard, P., & Iannetti, G. D. D. (2015) · Pain · doi:10.1097/j.pain.0000000000000253 · Cited by 86
Leading the Way to Solutions to the Opioid Epidemic: AOA Critical Issues
Seymour, R. B., Ring, D., Higgins, T., & Hsu, J. R. (2017) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.17.00066 · Cited by 74
Metadata
- Authors
- Bjordal, J. M., Johnson, M. I., & Ljunggreen, A. E.
- Venue
- European Journal of Pain
- Publisher
- Wiley
- Published
- 2003-04
- Volume
- 7
- Issue
- 2
- Pages
- 181-188
- ISSN
- 1090-3801 (ISSN-L)
- 1532-2149
- OpenAlex
- W2138681768
- Cited by
- 380
- References
- 38
- FWCI
- 6.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.