The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Ultrasonographic guidance reduces the amount of local anesthetic for 3-in-1 blocks*1
Abstract
BACKGROUND AND OBJECTIVES: Recently it has been demonstrated that the use of ultrasound (US) improves the onset time and the quality of sensory block for 3-in-1 blocks compared with conventional nerve stimulator (NS) techniques. The present study was designed to evaluate if US guidance for 3-in-1 blocks reduces the amount of local anesthetic compared to NS guidance. METHODS: After institutional approval and informed consent, 60 patients undergoing hip surgery following trauma were randomly assigned to three groups of 20 patients each. In group A, the 3-in-1 block was performed using US guidance with 20 mL 0.5% bupivacaine. Group B received 20 mL 0.5% bupivacaine, and group C received 30 mL 0.5% bupivacaine during NS guidance. The quality and the onset time was assessed by pinprick test in the central sensory region of each of the three targeted nerves and compared with the contralateral leg every 10 minutes for 1 hour by a blinded observer. The rating was undertaken using a scale from 100% (uncompromised sensibility) to 0% (no sensation). RESULTS: Overall success for the 3-in-1 block in group A was 95% and in groups B and C 80%. Onset time was significantly shorter in the US-guided group compared with both NS-guided groups (group A 13+/-6 minutes; group B 27+/-12 minutes; and group C 26+/-13 minutes; P < .01 to groups B and C). Quality of sensory block was significantly better in group A (4%+/-5% of initial value) compared with groups B and C (group B 21%+/-11% of initial value, P < .01 to group A; group C 22%+/-19%, P < .01 to group A). CONCLUSION: The amount of local anesthetic for 3-in-1 blocks can be reduced by using US guidance compared with the conventional NS-guided technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultrasonographic Guidance Improves Sensory Block and Onset Time of Three-in-One Blocks
Marhofer, P., Schrogendorfer, K., Koinig, H., Kapral, S., Weinstabl, C., & Mayer, N. (1997) · Anesthesia & Analgesia · doi:10.1097/00000539-199710000-00026 · Cited by 426
Self-citation
Cited by
Abrahams, M. S., Aziz, M. F., Fu, R. F., & Horn, J.-L. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aen384 · Cited by 506
Lower extremity regional anesthesia: essentials of our current understanding
Tran, D. Q., Salinas, F. V., Benzon, H. T., & Neal, J. M. (2019) · Regional Anesthesia & Pain Medicine · doi:10.1136/rapm-2018-000019 · Cited by 314
Comparative Effectiveness of Pain Management Interventions for Hip Fracture: A Systematic Review
Abou-Setta, A. M., Beaupre, L. A., Rashiq, S., Dryden, D. M., Hamm, M. P., Sadowski, C. A., Menon, M. R. G., Majumdar, S. R., Wilson, D. M., Karkhaneh, M., et al. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-4-201108160-00346 · Cited by 250
Riddell, M., Ospina, M., & Holroyd-Leduc, J. M. (2016) · CJEM · doi:10.1017/cem.2015.94 · Cited by 68
Metadata
- Authors
- MARHOFER, P.
- Venue
- Regional Anesthesia and Pain Medicine
- Publisher
- BMJ
- Published
- 1998-11
- Volume
- 23
- Issue
- 6
- Pages
- 584-588
- ISSN
- 1098-7339 (ISSN-L)
- OpenAlex
- W1990671807
- Cited by
- 319
- References
- 1
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasonographic guidance reduces the amount of local anesthetic for 3-in-1 blocks*1. https://app.cochat.ai/papers/10.1016/s1098-7339(98)90086-4
- The paper
- MARHOFER, P. (1998). Ultrasonographic guidance reduces the amount of local anesthetic for 3-in-1 blocks*1. Regional Anesthesia and Pain Medicine. https://doi.org/10.1016/s1098-7339(98)90086-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.