The DOI matches its Crossref record.
Ultrasonographic Guidance Improves Sensory Block and Onset Time of Three-in-One Blocks
Abstract
UNLABELLED: The use of ultrasound reduces the onset time, improves the quality of sensory block, and minimizes the risks associated with the supraclavicular approach for brachial plexus and stellate ganglion blockade. The present study was designed to evaluate whether ultrasound also facilitates the approach for 3-in-1 blocks. Forty patients (ASA physical status II or III) undergoing hip surgery after trauma were randomly assigned to two groups. In the ultrasound (US) group, 20 mL bupivacaine 0.5% was administered under US guidance, whereas in the control group, the same amount and concentration of local anesthetic was administered with the assistance of a nerve stimulator (NS). After US- or NS-based identification of the femoral nerve, the local anesthetic solution was administered, and the distribution of the local anesthetic solution was visualized and recorded on videotape in the US group. The quality and the onset of the sensory block was assessed by using the pinprick test in the central sensory region of each of the three nerves and compared with the same stimulation on the contralateral leg every 10 min for 60 min. The rating was performed using a scale from 100% (uncompromised sensibility) to 0% (no sensory sensation). Heart rate, noninvasive blood pressure, and oxygen saturation were measured at short intervals for 60 min. The onset of sensory blockade was significantly shorter in Group US compared with Group NS (US 16 +/- 14 min, NS 27 +/- 16 min, P < 0.05). The quality of the sensory block after injection of the local anesthetic was also significantly better in Group US compared with Group NS (US 15% +/- 10% of initial value, NS 27% +/- 14% of initial value, P < 0.05). A good analgesic effect was achieved in 95% of the patients in the US group and in 85% of the patients in the NS group. In the US group, visualization of the cannula tip, the femoral nerve, the major vessels, and the local anesthetic spread was possible in 85% of patients. Incidental arterial puncture (n = 3) was observed only in the NS group. We conclude that an US-guided approach for 3-in-1 block reduces the onset time, improves the quality of the sensory block and minimizes the risks associated with this regional anesthetic technique. IMPLICATIONS: The onset time and the quality of a regional anesthetic technique for the lower extremity is improved by ultrasonographic nerve identification compared with older techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Abrahams, M. S., Aziz, M. F., Fu, R. F., & Horn, J.-L. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aen384 · Cited by 506
Ultrasonographic guidance reduces the amount of local anesthetic for 3-in-1 blocks*1
MARHOFER, P. (1998) · Regional Anesthesia and Pain Medicine · doi:10.1016/s1098-7339(98)90086-4 · Cited by 319
Self-citationLower extremity regional anesthesia: essentials of our current understanding
Tran, D. Q., Salinas, F. V., Benzon, H. T., & Neal, J. M. (2019) · Regional Anesthesia & Pain Medicine · doi:10.1136/rapm-2018-000019 · Cited by 314
Comparative Effectiveness of Pain Management Interventions for Hip Fracture: A Systematic Review
Abou-Setta, A. M., Beaupre, L. A., Rashiq, S., Dryden, D. M., Hamm, M. P., Sadowski, C. A., Menon, M. R. G., Majumdar, S. R., Wilson, D. M., Karkhaneh, M., et al. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-4-201108160-00346 · Cited by 250
Metadata
- Authors
- Marhofer, P., Schrogendorfer, K., Koinig, H., Kapral, S., Weinstabl, C., & Mayer, N.
- Venue
- Anesthesia & Analgesia
- Published
- 1997-10
- Volume
- 85
- Issue
- 4
- Pages
- 854-857
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2030066467
- Cited by
- 426
- References
- 0
- FWCI
- 11.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasonographic Guidance Improves Sensory Block and Onset Time of Three-in-One Blocks. https://app.cochat.ai/papers/10.1097/00000539-199710000-00026
- The paper
- Marhofer, P., Schrogendorfer, K., Koinig, H., Kapral, S., Weinstabl, C., & Mayer, N. (1997). Ultrasonographic Guidance Improves Sensory Block and Onset Time of Three-in-One Blocks. Anesthesia & Analgesia. https://doi.org/10.1097/00000539-199710000-00026
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.