Concept, design and fabrication of smart orthopedic implants
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Extensive clinical experience has been built up using orthopaedic implants instrumented with strain gauges connected to a Wheatstone bridge by means of percutaneous leads. This research showed the medical relevance of the monitoring of the deformation of implants as a powerful tool to evaluate nursing and rehabilitation exercises, for tracing dangerous overloads and anticipating implant failure and also to observe the healing process. The IMPACT 3500 project focuses on the instrumentation of femoral implants with on board sensors: regular Benoist-Girard implants have been modified, to contain a 'sensing cell', and thoroughly tested in vitro and in vivo. The implant deformations are measured with resistive strain gauges, and the signal is transferred to a personal computer for processing and display, via a hard wired connection, or via a telemetry system. Two fully implantable wireless designs, called Linkstrain and Sealstrain, are powered from the outside by magnetic induction. As Sealstrain contains the whole telemetric system in its cavity, the highest miniaturization was required; this seriously deteriorates the efficiency of the inductive power link.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design of radio-frequency powered coils for implant instruments
Ko, W. H., Liang, S. P., & Fung, C. D. F. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457921 · Cited by 374
Cited by
From Diagnosis to Treatment: Recent Advances in Patient-Friendly Biosensors and Implantable Devices
Li, P., Lee, G.-H., Kim, S. Y., Kwon, S. Y., Kim, H.-R., & Park, S. (2021) · ACS Nano · doi:10.1021/acsnano.0c06688 · Cited by 359
Antoci, V., Adams, C. S., Parvizi, J., Davidson, H. M., Composto, R. J., Freeman, T. A., Wickstrom, E., Ducheyne, P., Jungkind, D., Shapiro, I. M., et al. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.08.016 · Cited by 233
“Finally, addition of many antibiotics to PMMA is not possible as the exothermic reaction caused by curing of the cement results in heat inactivation of the drug [13,14].”
BackgroundThe Use of Piezoelectric Ceramics for Electric Power Generation Within Orthopedic Implants
Platt, S. R., Farritor, S., Garvin, K., & Haider, H. (2005) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2005.852482 · Cited by 232
An inductive power system with integrated bi-directional data-transmission
Catrysse, M., Hermans, B., & Puers, R. (2004) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2004.02.016 · Cited by 177
Self-citationHydrophobic polycationic coatings that inhibit biofilms and support bone healing during infection
Schaer, T. P., Stewart, S., Hsu, B. B., & Klibanov, A. M. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.10.038 · Cited by 160
Metadata
- Authors
- Burny, F., Donkerwolcke, M., Moulart, F., Bourgois, R., Puers, R., Van Schuylenbergh, K., Barbosa, M., Paiva, O., Rodes, F., Bégueret, J. B., & Lawes, P.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2000-09-01
- Volume
- 22
- Issue
- 7
- Pages
- 469-479
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2013262537
- Cited by
- 125
- References
- 1
- FWCI
- 0.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Concept, design and fabrication of smart orthopedic implants. https://app.cochat.ai/papers/10.1016/s1350-4533(00)00062-x
- The paper
- Burny, F., Donkerwolcke, M., Moulart, F., Bourgois, R., Puers, R., Van Schuylenbergh, K., Barbosa, M., Paiva, O., Rodes, F., Bégueret, J. B., & Lawes, P. (2000). Concept, design and fabrication of smart orthopedic implants. Medical Engineering & Physics. https://doi.org/10.1016/s1350-4533(00)00062-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.