The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The Use of Piezoelectric Ceramics for Electric Power Generation Within Orthopedic Implants
Abstract
This paper presents the results of tests that demonstrate the feasibility of using piezoelectric (PZT) ceramics to generate in vivo electrical energy for orthopedic implants. Sensors encapsulated within implants could provide in vivo diagnostic capabilities such as the monitoring of implant duty (i.e., walking) cycle, detecting abnormally asymmetric or high forces, sensing misalignment and early loosening, and early detection of wear. Early diagnosis of abnormalities or impending failure is critical to minimize patient harm. However, the routine use of sensors and microprocessors embedded within orthopedic implants for diagnostic and monitoring purposes has been limited by the lack of a long-term self-contained power source capable of lasting the expected 20-year implant lifetimes. By embedding PZT materials within orthopedic implants, a small amount of the mechanical energy generated during normal physical activity can be converted into useful electrical energy. This in vivo energy source can power embedded microprocessors and sensors for a broad range of biomedical uses. The current work investigates the application of this technology to total knee replacement (TKR) implants, but it is applicable to many other implanted biomedical devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human-powered wearable computing
Starner, T. (1996) · IBM Systems Journal · doi:10.1147/sj.353.0618 · Cited by 876
Cited by
Energy harvesting vibration sources for microsystems applications
Beeby, S. P., Tudor, M. J., & White, N. M. (2006) · Measurement Science and Technology · doi:10.1088/0957-0233/17/12/r01 · Cited by 3,008
Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975
Flexible High-Output Nanogenerator Based on Lateral ZnO Nanowire Array
Zhu, G., Yang, R., Wang, S., & Wang, Z. L. (2010) · Nano Letters · doi:10.1021/nl101973h · Cited by 805
In Vivo Powering of Pacemaker by Breathing‐Driven Implanted Triboelectric Nanogenerator
Zheng, Q., Shi, B., Fan, F., Wang, X., Yan, L., Yuan, W., Wang, S., Liu, H., Li, Z., & Wang, Z. L. (2014) · Advanced Materials · doi:10.1002/adma.201402064 · Cited by 603
Muscle‐Driven In Vivo Nanogenerator
Li, Z., Zhu, G., Yang, R., Wang, A. C., & Wang, Z. L. (2010) · Advanced Materials · doi:10.1002/adma.200904355 · Cited by 441
Metadata
- Authors
- Platt, S. R., Farritor, S., Garvin, K., & Haider, H.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2005-08
- Volume
- 10
- Issue
- 4
- Pages
- 455-461
- ISSN
- 1083-4435 (ISSN-L)
- OpenAlex
- W2100725179
- Cited by
- 232
- References
- 1
- FWCI
- 12.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Use of Piezoelectric Ceramics for Electric Power Generation Within Orthopedic Implants. https://app.cochat.ai/papers/10.1109/tmech.2005.852482
- The paper
- Platt, S. R., Farritor, S., Garvin, K., & Haider, H. (2005). The Use of Piezoelectric Ceramics for Electric Power Generation Within Orthopedic Implants. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2005.852482
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.