The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Automatic recognition of alertness and drowsiness from EEG by an artificial neural network
Abstract
We present a novel method for classifying alert vs drowsy states from 1 s long sequences of full spectrum EEG recordings in an arbitrary subject. This novel method uses time series of interhemispheric and intrahemispheric cross spectral densities of full spectrum EEG as the input to an artificial neural network (ANN) with two discrete outputs: drowsy and alert. The experimental data were collected from 17 subjects. Two experts in EEG interpretation visually inspected the data and provided the necessary expertise for the training of an ANN. We selected the following three ANNs as potential candidates: (1) the linear network with Widrow-Hoff (WH) algorithm; (2) the non-linear ANN with the Levenberg-Marquardt (LM) rule; and (3) the Learning Vector Quantization (LVQ) neural network. We showed that the LVQ neural network gives the best classification compared with the linear network that uses WH algorithm (the worst), and the non-linear network trained with the LM rule. Classification properties of LVQ were validated using the data recorded in 12 healthy volunteer subjects, yet whose EEG recordings have not been used for the training of the ANN. The statistics were used as a measure of potential applicability of the LVQ: the t-distribution showed that matching between the human assessment and the network output was 94.37+/-1.95%. This result suggests that the automatic recognition algorithm is applicable for distinguishing between alert and drowsy state in recordings that have not been used for the training.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multilayer feedforward networks are universal approximators
Hornik, K., Stinchcombe, M., & White, H. (1989) · Neural Networks · doi:10.1016/0893-6080(89)90020-8 · Cited by 21,728
Mackay, D. J. C. (1995) · Network Computation in Neural Systems · doi:10.1088/0954-898x/6/3/011 · Cited by 915
Cited by
Using EEG spectral components to assess algorithms for detecting fatigue
Jap, B. T., Lal, S., Fischer, P., & Bekiaris, E. (2009) · Expert Systems with Applications · doi:10.1016/j.eswa.2007.12.043 · Cited by 729
Automatic recognition of alertness level from EEG by using neural network and wavelet coefficients
SUBASI, A. (2005) · Expert Systems with Applications · doi:10.1016/j.eswa.2004.12.027 · Cited by 289
Cross-session classification of mental workload levels using EEG and an adaptive deep learning model
Yin, Z., & Zhang, J. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.11.013 · Cited by 163
Metadata
- Authors
- Vuckovic, A., Radivojevic, V., Chen, A. C. N., & Popovic, D.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2002-05-06
- Volume
- 24
- Issue
- 5
- Pages
- 349-360
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W1999269011
- Cited by
- 198
- References
- 2
- FWCI
- 2.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic recognition of alertness and drowsiness from EEG by an artificial neural network. https://app.cochat.ai/papers/10.1016/s1350-4533(02)00030-9
- The paper
- Vuckovic, A., Radivojevic, V., Chen, A. C. N., & Popovic, D. (2002). Automatic recognition of alertness and drowsiness from EEG by an artificial neural network. Medical Engineering & Physics. https://doi.org/10.1016/s1350-4533(02)00030-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.