The use of accelerometry to detect heel contact events for use as a sensor in FES assisted walking
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Current sensors for the control of functional electrical stimulation (FES) assisted walking in hemiplegic individuals are not wholly satisfactory, as they are either not implantable or ineffectual in the detection of heel contact events. This study describes the use of an accelerometer placed on the trunk to detect heel contact events of both legs based on the examination of the anterior-posterior horizontal acceleration signal. Four subjects wore an accelerometer over their lumbar spine. Footswitches placed on the sole of one foot recorded the heel contact and heel off times for that foot. The acceleration signal was reduced to a series of pulses by studying the negative-positive changes in acceleration. It was found that there was approximately a 150 ms delay between heel contact and the negative-positive change in acceleration. This delay was consistent across different walking speeds, but was different between subjects and when hemiplegic gait was simulated. Therefore, accelerometers placed on the trunk are valid sensors for the detection of heel contact events during FES assisted walking.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wt, L., Holmquest, H. J., Scot, D., & Dow, M. (1961) · PubMed · Cited by 1,033
“Stops walking when talking” as a predictor of falls in elderly people
Lundin-Olsson, L., Nyberg, L., & Gustafson, Y. (1997) · The Lancet · doi:10.1016/s0140-6736(97)24009-2 · Cited by 975 · cited 1×
“However, hand switches increase the attentional demands of walking, which may reduce the patient’s capacity to respond to perturbations to their balance [14], leading to an increased risk of a fall event.”
BackgroundBurridge, J., Taylor, P., Hagan, S., Wood, D., & Swain, I. (1997) · Clinical Rehabilitation · doi:10.1177/026921559701100303 · Cited by 323
Gait parameters following stroke: a practical assessment.
von Schroeder, H. P., Coutts, R. D., Lyden, P. D., Billings, E., & Nickel, V. L. (1995) · PubMed · Cited by 317
Glanz, M., Klawansky, S., Stason, W., Berkey, C., & Chalmers, T. C. (1996) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(96)90293-2 · Cited by 254
Kitchen, S. S. (2001) · Physiotherapy · doi:10.1016/s0031-9406(05)61116-9 · Cited by 175
Automatic stance-swing phase detection from accelerometer data for peroneal nerve stimulation
Willemsen, A. T. M., Bloemhof, F., & Boom, H. B. K. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.64463 · Cited by 169 · cited 1×
“Other studies [15,18,19] have used accelerometers placed on the leg to detect heel contact events.”
BackgroundCutaneous whole nerve recordings used for correction of footdrop in hemiplegic man
Haugland, M. K., & Sinkjaer, T. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481970 · Cited by 168
Aminian, K., Rezakhanlou, K., De Andres, E., Fritsch, C., Leyvraz, P. F., & Robert, P. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513368 · Cited by 165
Gait event detection for FES using accelerometers and supervised machine learning
Williamson, R., & Andrews, B. J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867873 · Cited by 164 · cited 2×
“1 and 2, are much easier to interpret than those reported by Williamson and Andrews [18].”
BackgroundResultThe Use of a Four-Channel Electrical Stimulator as an Ambulatory Aid for Paraplegic Patients
Bajd, T., Kralj, A. R., Turk, R., Benko, H., & Šega, J. (1983) · Physical Therapy · doi:10.1093/ptj/63.7.1116 · Cited by 130
Biofeedback and functional electric stimulation in stroke rehabilitation.
Cozean, C. R. D., Ws, P., & Sl, H. (1988) · PubMed · Cited by 122
Experience of Clinical Use of the Odstock DroppedFoot Stimulator
Burridge, J., Taylor, P., Hagan, S., & Swain, I. (1997) · Artificial Organs · doi:10.1111/j.1525-1594.1997.tb04662.x · Cited by 110 · cited 1×
“While FES systems have proved successful in improving walking ability in stroke patients by improving walking speed, functional mobility, step length on the affected side, ankle flexion, muscle strength, motor coordination and balance [2–8], there are some fundamental problems associated with their use.”
BackgroundStefanovska, A., Vodovnik, L., Gros, N., Rebersek, S., & Aćimović-Janežič, R. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32106 · Cited by 76
Sensor systems for lower limb functional electircal stimulation (FES) control
Williamson, R., & Andrews, B. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(00)00038-2 · Cited by 42 · cited 4×
“Additionally, the accuracy of heel contact detection found in this study is comparable to accuracies obtained previously, when more involved rules for heel contact detection were used [15].”
BackgroundMethodResultInfluentialMeasurement of gait by accelerometer and walkway: A comparison study
Currie, G., Rafferty, D., Duncan, G., Bell, F., & Evans, A. L. (1992) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446803 · Cited by 30
DEVELOPMENT OF A UNIVERSAL CONTROL UNIT FOR FUNCTIONAL ELECTRICAL STIMULATION (FES)1
Brandell, B. R. (1982) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-198212000-00002 · Cited by 16 · cited 3×
“Originally, footswitches, usually based on force sensitive resistors, were placed on the sole of the foot and used as sensors for FES [2].”
BackgroundMethod
Cited by
Window Size Impact in Human Activity Recognition
Banos, O., Galvez, J.-M., Damas, M., Pomares, H., & Rojas, I. (2014) · Sensors · doi:10.3390/s140406474 · Cited by 648
Accelerometry: A technique for quantifying movement patterns during walking
Kavanagh, J. J., & Menz, H. B. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.10.010 · Cited by 617
Activity identification using body-mounted sensors—a review of classification techniques
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., Howard, D., Meijer, K., & Crompton, R. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/4/r01 · Cited by 600
Automatic detection of gait events using kinematic data
O’Connor, C. M., Thorpe, S. K., O’Malley, M. J., & Vaughan, C. L. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.05.016 · Cited by 557
Neuromuscular electrical stimulation in neurorehabilitation
Sheffler, L. R., & Chae, J. (2007) · Muscle & Nerve · doi:10.1002/mus.20758 · Cited by 529
Metadata
- Authors
- Mansfield, A., & Lyons, G. M.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2003-10-10
- Volume
- 25
- Issue
- 10
- Pages
- 879-885
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2087608218
- Cited by
- 160
- References
- 17
- FWCI
- 2.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.